1 Battery
2 Configuration (rocker) Switch SW1
Switch 1-4 Microprocessor speed
Switch 5 ROM operation mode
Switch 6 Ethernet controller operation mode
Switch 7 Administrator password
Switch 8 Diskette write-protect
3 Microprocessor Socket
4 DIMM Socket 0
5 DIMM Socket 1
6 DIMM Socket 2
7 CMOS Clear Jumper (J9)
8 AGP slot connector for optional AGP adapter
9 Display Connector
10 Mouse / Keyboard Connector
(top = Mouse / bottom = Keyboard)
11 Serial Connectors
(top = Serial port 2 / bottom = Serial port 1)
12 USB Connectors
(top = USB port 2 / bottom = USB port 1)
13 Parallel Connector
14 Ethernet RJ45 Connector
15 Audio Line Out
16 Audio Line In
17 Microphone Connector
The following tables contains the switch settings.
(D) indicates the default setting.
CMOS Reset (J9)
See > Security / Password
Jumper | Setting | Description |
---|---|---|
CMOS Reset | 2-3 | CMOS reset |
Normal Work | 1-2 | Normal |
Pentium® II - Processor Speed Switch Setting (SW1 1-4)
CPU Switch Settings |
SW1 - 1 | SW1 - 2 | SW1 - 3 | SW1 - 4 |
---|---|---|---|---|
266/66 MHz | ON | ON | Off | ON |
300/66 MHz | Off | ON | Off | ON |
350/100 MHz | Off | Off | ON | ON |
400/100 MHz | ON | ON | Off | ON |
Processors of 450MHz and up will automatically set their internally speeds,
so the switch setting is not applicable.
ROM Operation Switch (SW1-5) (Recovery mode)
See > ROM Operation Mode Switch Setting
ROM Operation | SW1-5 |
---|---|
ROM Recovery Mode | ON |
Normal ROM Operation | Off (D) |
Ethernet Controller Operation Mode Switch (SW1-6)
Operation Mode | SW1-6 |
---|---|
Ethernet Normal Operation | Off |
Ethernet MAC Disabled | ON |
Administrator Password Switch (SW1-7)
See > Security / Password
PAP | SW1-7 |
---|---|
Admin Password Locked | Off |
Admin Password Unlocked | On |
Diskette Write Access Switch (SW1-8)
Diskette Access | SW1-8 |
---|---|
Write Enabled | Off (D) |
Write Disabled | On |
Memory Configuration
The maximum amount of system memory the server supports is 384 MB.
The memory modules that the server uses are DIMMs. The DIMMs that come with the server are
synchronous dynamic random-access memory (SDRAM) with error checking and correction (ECC). These memory modules have a
speed of 100 MHz.
Use only 3.3 Vdc unbuffered, ECC, 100 MHz SDRAM DIMMs.
When you are adding or removing memory, fill each system memory connector sequentially, starting at DIMM 0.
(If NP-DIMMs are installed, the server will not power up, and POST memory error code 164 will be displayed).
The below table show some possible memory configurations for the server. Alternative configurations are possible.
Total Memory (MB) | DIMM 0 | DIMM 1 | DIMM 2 |
---|---|---|---|
32 | 32 | -- | -- |
64 | 64 | -- | -- |
64 | 32 | 32 | -- |
96 | 64 | 32 | -- |
96 | 32 | 32 | 32 |
128 | 128 | -- | -- |
128 | 64 | 32 | 32 |
128 | 64 | 64 | -- |
192 | 64 | 64 | 64 |
256 | 128 | 64 | 64 |
256 | 128 | 128 | -- |
384 | 128 | 128 | 128 |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.