Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Keyboard/Mouse Port



AT - PS/2 style KEYBOARD/MOUSE Port Connectors

 


Use the below Voltage Chk marked column for DC-Voltage measurements. (all voltages are plus/minus 5%)

NOTE: If a mouse or other pointing device is attached, remove it to see if the error symptom goes away.
If the symptom goes away, the mouse or pointing device is defective.

PS/2-CPU AT-CPU KBD KBD
Signal-name
Mouse
Signal-name
Combined
KBD / Mouse
Voltage Chk.
- - - - - Aptiva
2158, 2163
2164
-
1 2 B +KBD Data +Mouse Data +KBD Data +5.0 Vdc
2 *) --- F not used not used +Mouse Data ---
3 4 C Ground Ground Ground Ground
4 5 E +5 Vdc +5 Vdc +5 Vdc +5.0 Vdc
5 1 D +KBD Clock +Mouse Clk +KBD Clock +5.0 Vdc
6 *) --- A Not used Not used +Mouse Clock ---
Shield Shield Shield Frame GND Frame GND Frame GND ---


*) This pin may be not available, or, if available - not connected.


Serial-port / PS/2-MOUSE-port - Adapter
for LogiTech PilotMouse+ (Logitech MouseWare for Windows)

 