Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes (3550)



Numeric Error Codes

Symptom/Error    FRU/Action
  
000113XX 1. Any Adapter
  2. System Board of 3550 Expansion Unit
  3. Any Drive
  
000114XX 1. Any Adapter
  
00016300, 00016400, 1. Set Configuration/ Features
00016500 2. System Board of 3550 Expansion Unit
(If setting configuration does
not solve the problem, see
'Checking the Installed Devices List'
000166XX 1. Any Adapter
  
00017400 1. Set Configuration/Features
(If 'Automatic Configuration' 2. Any Device
does not solve the problem, 3. System Board of 3550 Expansion Unit
run Advanced Diagnostics.)
0001XXXX 1. System Board of 3550 Expansion Unit
(not listed above) 2. Any Adapter
  
00030700 1. External Keyboard
  2. Keyboard Cable
  
00030X00 1. Keyboard
(not listed above) 2. System Board of 3550 Expansion Unit
  3. Keyboard Cable
  
000401XX 1. System Board of 3550 Expansion Unit
  
00110200, 00110600 1. System Board of 3550 Expansion Unit
  2. Any Serial Device
  
00110700 1. Communication Cable
  2. System Board of 3550 Expansion Unit
  
0011XX00 1. System Board of 3550 Expansion Unit
(not listed above)
Check the power supply
voltages before replacing
the system board of the
3550 Expansion Unit. (See
'Power Systems Checkout'.)
00120700 1. Communication Cable
  2. Dual Async Adapter/A
  
0012XX00 1. Dual Async Adapter/A
(not listed above) 2. System Board of 3550 Expansion Unit
  3. Any Serial Device
  
0014XX00 1. Printer
(See 'Printer Checkout' 2. System Board of 3550 Expansion Unit
before replacing any FRUs.)
00186XXX 1. Set Configuration/ Features
  2. Backup Battery
  
0018XXXX 1. System Board of 3550 Expansion Unit
(not listed above)
00240100 1. External Display
(See 2. System Board of 3550 Expansion Unit
'External Display Self-Test'
before replacing any FRUs.)
00241000 1. System Board of 3550 Expansion Unit
  
00860100, 00860200 1. Pointing Device
  2. System Board of 3550 Expansion Unit
  
00860300 1. System Board of 3550 Expansion Unit
  
00860400 1. System Board of 3550 Expansion Unit
  2. Pointing Device (Mouse)
  
0106XXXX 1. Ethernet Network Adapter/A
  2. System Board of 3550 Expansion Unit
  
0137XXXX 1. System Board of 3550 Expansion Unit
  
016500XX 1. 6157 Tape Attachment Adapter
  
016520XX 1. 6157 Streaming Tape Drive
  
016540XX 1. 6157 Streaming Tape Drive
  2. 6157 Tape Attachment Adapter
  
0166XXXX, 0167XXXX 1. Token-Ring Network Adapter/A
(For diagnostic information, 2. System Board of 3550 Expansion Unit
refer to the Token-Ring Network
Adapter/A service information.)
0210XXXA (60MB) 1. SCSI Hard Disk Drive
0210XXXB (80MB) 2. System Board of 3550 Expansion Unit
0210XXXC (120MB) 3. SCSI Adapter (if used)
0210XXXD (160MB) 4. SCSI Cable
0210XXXE (320MB)
0210XXXF (400MB)
0210XXXG (40MB)
0210XXXH (1GB)
0210XXXI (108MB)
0210XXXJ (216MB)
0210XXXU
(Size undetermined)
(If the failing device is an
external device, go to the
external devices service pamphlet.)
0211XXXX 1. SCSI Tape Drive
(If the failing device is an 2. System Board of 3550 Expansion Unit
external device, go to the 3. SCSI Adapter (if used)
external devices service pamphlet.) 4. SCSI Cable
  
0215XXXX 1. SCSI CD-ROM Drive
(If the failing device is an 2. System Board of 3550 Expansion Unit
external device, go to the 3. SCSI Adapter (if used)
external devices service pamphlet.) 4. SCSI Cable
  
0217XXXX 1. SCSI Rewritable Optical Drive
(If the failing device is an 2. System Board of 3550 Expansion Unit
external device, go to the 3. SCSI Adapter (if used)
external devices service pamphlet.) 4. SCSI Cable
  
0260XXXX 1. System Board of 3550 Expansion Unit
  2. Any SCSI Device
  
I998009X 1. Restore System Partition


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.