Symptom/Error | SelectaDock Docking System |
---|---|
FRUs Sequence of Actions | |
10X, 11X | 1. Adapter in slot (if used) |
101: Interrupt failure. | 2. Riser card |
102: Timer failure. | 3. Main card |
103: Timer interrupt failure. | |
104.: Protected mode failure. | |
105: Last 8042 command not accepted. | |
107: NMI test failure. | |
108: Timer bus test failure. | |
109: Low meg-chip select test. | |
195 | 1. Do the following steps. |
(The computer was docked to the | a. Power-off and undock the system. |
SelectaDock Docking System while | b. Power-on and shut down the system. |
in hibernation mode.) | c. Power-off and dock the system. |
1XX | 1. See the Hardware Maintenance Manual |
of the computer. | |
If the problem remains, go to 'Undetermined Problems' | |
2XX | 1. See the Hardware Maintenance Manual. |
201: Memory data error. | of the computer. |
202: Memory line error 00-15. | 2. Main card |
203: Memory line error 16-23. | |
205: Memory test failure on on-board memory. | |
221: ROM to RAM remap error. | |
3XX | 1. See 'External Keyboard' |
6XX | 1. Before changing any devices, |
run the diagnostic test. | |
(See the 'How to Run the Diagnostics') | |
2. FDD external attachment kit | |
3. Diskette drive assembly | |
4. Riser card | |
11XX, 12XX | 1. Serial devices |
2. Communication cable | |
3. Riser card | |
17XX | 1. Hard disk drive |
2. Main card | |
(2.5-inch ThinkPad hard disk drive) | |
24XX | 1. Main card |
2. Riser card | |
860X | 1. Mouse |
2. External keyboard | |
3. Riser card | |
I9990301, I9990302 | 1. See the Hardware Maintenance Manual. |
I9990305 | of the computer. |
Not shown above | 1. See the Hardware Maintenance Manual |
2. See 'Undetermined Problems'. | |