|001| START
+---+
- Power off the system unit and monitor.
- Remove all adapter cards.
- Make sure that the monitor I/O signal cable is properly connected to
the system unit and monitor.
- Make sure that the power cords are properly connected to the system
unit and monitor, and that the line voltage is correct.
- Make sure that the monitor contrast and brightness controls are not
turned too low.
- Make sure that the diagnostics diskette is in the diskette drive.
- Power on the monitor, and wait 20 seconds.
- Power on the system unit.
NOTE: If the monitor was not sold together with the system
unit, you may need to refer to the service information provided with
the monitor.
+---+
|002|
+---+
IS THE SCREEN READABLE? (YES, read ahead, NO, go to Step 004)
NOTE: If the screen shows a blinking cursor with no memory
count running, then go to Step 004.
- Select Interactive Tests from the Main Menu.
- Select and execute Video test from the menu.
- Follow the prompts and perform the video test.
- Go to 'Index of Symptoms, Messages, Error Codes, or Beeps'
NOTE: You might have to adjust the monitor controls to
obtain the best image.
+---+
|003|
+---+
DOES THE MONITOR SUCCESSFULLY PASS ALL TESTS? (YES, read ahead, NO, go to Step 004)
- You have successfully completed the video diagnostics test. If the
problem remains, go to 'Index of Symptoms, Messages, Error Codes, or Beeps'
- END.
+---+
|004|
+---+
- Power off the system unit.
- Remove the hard disk drive system cable.
- Power on the system unit.
+---+
|005|
+---+
IS THE SCREEN READABLE?
- Replace the monitor. If the symptom remains, replace the system board.
- END.