| Error Code | FRU/Action |
|---|---|
| 0210XXXX | 1. SCSI Hard Disk Drive |
| (Internal bus size unknown) | 2. SCSI Adapter or the SCSI controller built |
| into the system board. | |
| 0210XXXX | 3. SCSI Cable |
| (External bus size unknown) | 4. SCSI ID Switch (on some models) |
| 0270xxxx | 1. RAID Controller Error |
| For explanation see RAID Diagnostic Error Codes | |
| 0271abcd | 1. RAID Device Error |
| a = Bay Number | |
| b = Channel Number | |
| c = Slot Number | |
| d = ID or PUN number of Device | |
| see SCSI/Non-SCSI Error Code Format | |
| For explanation see RAID Diagnostic Error Codes | |
| 02790XXX 02791XXX | 1. Check power and reseat adapter |
| 02792XXX 02793XXX | 2. Ethernet PeerMaster Server Adapter |
| 027906XX 027907XX | |
| (Ethernet adapter POST | |
| error) | |
| 02799XXX | 1. Run Setup and verify the |
| (Communications to the | Ethernet PeerMaster Server Adapter |
| Ethernet PeerMaster Server | configuration |
| Adapter failed or the | 2. Ethernet PeerMaster Server Adapter |
| adapter failed. | |
| 0279XXXX | 1. Fast/Wide Streaming RAID Adapter/A |
| (FRU P/N 06H3059) or Signal | |
| Pass Through Card (FRU P/N 06H3060) | |
| 2. System Board | |
| 3. Signal Pass Through Card (if installed) |
Please see the LEGAL - Trademark notice.
Feel free - send a