RDDDPLSCB QEET
|--+||||| |-+|
| |||||| | |+--- Test state
| |||||| | +---- Error code Extension
| |||||| +------ Qualifier
| ||||||
| |||||+-------- Bus (0=internal 1=external)
| ||||+--------- Capacity of the device
| |||+---------- Slot number of the device
| ||+----------- LUN (usually 0)
| |+------------ PLUN (SCSI ID #)
| |
| +------------- Device Number
+---------------- Reserved Digit (usually 0)
As an example, if you have SCSI error code 021050A0, each digit decodes as follows:
| Digit | Information |
|---|---|
| 0 | Reserved digit (usually 0) |
| 210 | Device number 210 indicates hard disk |
| 5 | SCSI ID assigned is 5 |
| 0 | Logical Unit Number (not used, usually 0) |
| A | The device capacity is 60MB (A=60MB) |
| 0 | The device is connected to the internal bus |
RDDD Codes for Adapters
| RDDD | Device Type or Information |
|---|---|
| 0037 | SCSI on the System board |
| 0096 | SCSI adapter with cache |
| 0112 | SCSI adapter w/o cache |
| 0206 | SCSI-2 adapter |
RDDD Codes for Devices
| RDDD | Device Type or Information |
|---|---|
| 0208 | Unknown device type |
| 0209 | Direct access - removable media, and/or other than 512 byte blocks |
| 0210 | Direct access - hard disk, 512 byte blocks |
| 0211 | Sequential access (tape) |
| 0212 | Printer |
| 0213 | Processor |
| 0214 | Write Once, Read Multiple (W.O.R.M.) |
| 0215 | Read only (CD-ROM) |
| 0216 | Scanner |
| 0217 | Optical Memory (read/write optical disk) |
| 0218 | Changer (multiple tray CD-ROM) |
| 0219 | Communications |
B Codes
| B | Device Type or Information |
|---|---|
| 0 | Dual SCSI adapter (internal bus) |
| 1 | Dual SCSI adapter (external bus) |
QEET 0000 Codes
| PLSC | QEET | Information |
|---|---|---|
| 0100 | 0000 | On systems with NVRAM, SCSI setup data not located, or the checksum did not verify. On systems w/o NVRAM (Model 8550 for example), setup data must be on the 1st hard disk. |
| 0200 | 0000 | Configuration error. No hard disk found at PUN 6, LUN 0 for 161, 162, 165 system error path. Might be an unsupported configuration. |
| 0300 | 0000 | No space available in extended BIOS data area for SCSI data table (possibly to many adapters installed). |
| 0400 | 0000 | ROM modules not found on adapter (IML based systems only). Running setup might correct it. |
| 0500 | 0000 | ROM checksum error on 2nd 16K portion of 32K ROM |
| 0600 | 0000 | ROM access control port error |
QEET Errors (other than 0000)
These are specific QEET error codes (preceded by a DDD indicating an adapter).
NOTE:
A number in slot S indicates an error on the adapter, (or device
attached to the adapter) in slot S If S is 0, suspect the system board.
| QEET | Information |
|---|---|
| 001x | 8032/80188/80C186 ROM test failure |
| 002x | Local RAM test failure |
| 003x | Bad fuse, or bad termination, or local RAM address failure on SCSI adapter if RDDD is 0112. |
| 004x | Internal peripheral test failure |
| 005x | Buffer control chip test failure, or LTB failed, (or system-board SCSI failed if RDDD is 0037. |
| 006x | Undefined error condition, or buffer RAM test failure on SCSI adapter if RDDD is 0096 |
| 007x | System interface control chip test failure |
| 008x | SCSI internal interface test failed |
| 00Ax | SCSI external interface test failed |
| 107x | Adapter hardware failure |
| 10Cx | Command failed |
| 10Ex | Command error (invalid command or parameter) |
| 10Fx | Sequencing error |
| 110x | Adapter internal error log contains entries. (Reported if no other errors on adapter exist.) |
| 180x | Time out |
| 181x | Adapter busy error |
| 182x | Unexpected interrupt presented by adapter |
| 183x | Adapter register test failure |
| 184x | Adapter reset failure |
| 185x | Adapter buffer test failure (on cached adapters) |
| 186x | Adapter reset count expired |
| 187x | Adapter registers not cleared on reset |
| 188x | Card ID in adapter microcode did not match ID in POS registers |
| 190x | Expected device did not respond |
| 19Yx | DMA arbitration level conflict (Y=assigned arbitration level) |
| 220x | Adapter hardware error |
| 221x | Global timeout on adapter (device did not respond) |
| 222x | Adapter DMA error |
| 223x | Adapter buffer defective |
| 224x | Command aborted by adapter |
| 301x | Invalid parameter in SCB |
| 303x | Command not supported |
| 304x | Command aborted by system |
| 305x | Command rejected (buffer not disabled) |
| 306x | Command rejected (Adapter diagnostic failure) |
| 307x | Format rejected |
| 308x | Assign rejected (command in process) |
| 309x | Assign rejected (device already assigned) |
| 30Ax | Command rejected (device not assigned) |
| 30Bx | Command rejected (maximum LBA exceeded) |
| 30Cx | Command rejected (16 bit card slot address range exceeded) |
| 313x | Invalid device for command |
| 3FFx | Status not returned by adapter |
| 401x | Recovered error (not an error condition) |
| 402x | Device not ready |
| 403x | Device medium error |
| 404x | Device hardware error |
| 405x | Illegal request for device |
| 406x | Device unit attention would not clear |
| 407x | Device data protect error |
| 409x | Device vendor unique error |
| 40Ax | Copy operation aborted by device |
| 40Bx | Device command aborted |
| 40Cx | Device search data command satisfied |
| 40Dx | Device volume overview (residual data remains in buffer) |
| 40Ex | Device mismatch (source data did not match medium data) |
| 500x | Check condition on device, no sense data returned |
| 501x | No index or sector |
| 502x | Seek incomplete |
| 503x | Write fault |
| 504x | Drive not ready |
| 505x | Drive not selected |
| 506x | No track zero found |
| 507x | Multiple drives selected |
| 508x | Logical unit communication failure |
| 509x | Head positioning error (track following error) |
| 510x | CRC or ECC error in ID field |
| 511x | Unrecoverable read error |
| 512x | No address mark (ID field) |
| 512x | No address mark (data field) |
| 514x | Record not found |
| 515x | Seek error |
| 516x | Data synchronization error |
| 517x | Recoverable read error |
| 518x | ECC recovered read error |
| 519x | Defect list error |
| 51Ax | Parameter overrun |
| 51Bx | Synchronous transfer error |
| 51Cx | Primary defect list not found |
| 51Dx | Compare error |
| 520x | Invalid command |
| 521x | Illegal logical block address (LBA) |
| 522x | Illegal function for device type |
| 524x | Illegal command block field |
| 525x | Invalid LUN |
| 526x | Illegal field in parameter list |
| 528x | Media changed |
| 529x | Power-on or bus device reset occurred (not an error) |
| 52Ax | Mode select parameters changed (not an error) |
| 531x | Media format corrupted |
| 532x | Defect spare location unavailable |
| 540x | Device RAM failure |
| 541x | Data path diagnostic failure |
| 542x | Power-on diagnostic failure |
| 543x | Message rejected |
| 544x | Internal controller error |
| 545x | Device was unable to reconnect |
| 547x | Interface parity error |
| 548x | Initiator detected error |
| 549x | Illegal command or command out of sequence error |
| 5F0x | Format in progress (not an error) |
| 5F1x | Spinup in progress |
| 601x | SCSI bus reset occurred |
| 602x | SCSI interface fault |
| 610x | Selection timeout error (device not available) |
| 611x | Unexpected bus free |
| 612x | Mandatory SCSI message rejected |
| 613x | Invalid SCSI phase sequence |
| 620x | Short length record error |
| 702x | Device not ready (removable media devices) |
| 704x | Device not ready (non removable media devices) |
| 728x | Media changed error would not clear |
| 731x | Medium format corrupted (format unit interrupted - format must be issued again) |
| 7F0x | Format in progress (prior format unit issued being completed) |
| 7F1x | Spinup in progress |
Q Codes
All error codes with Q = 1 are developed using information returned by either an adapter or
device. The Q value defines the origin of the EE code that is reported.
Error codes (EE) with Q = 4 or 5 may be reported that are not listed here or can actually have
a definition other than that given, depending on the device.
| Q | Information |
|---|---|
| 2 | Command error field of command complete status block returned by the adapter |
| 3 | SCSI Status field of the command complete status block or command error field values indicating software problems (<20H) |
| 4 | Sense key value returned by a device |
| 5 | Additional sense byte (byte 12) of sense information from device |
| 6 | Device error code field of command complete status block |
| 7 | Device errors not normally considered an error, but considered an error based on when the code was returned (medium corrupted error on device with non removable media) |
Test Status Codes
| T | Information |
|---|---|
| O | Not applicable for error code |
| A | Adapter initialization error |
| B | Adapter reset |
| C | Adapter register test |
| D | Adapter buffer test phase 1 (on cached adapters) |
| E | Adapter buffer test phase 2 (on cached adapters) |
| F | Adapter buffer test phase 3 (on cached adapters) |
| G | Adapter buffer test phase 4 (on cached adapters) |
| H | Adapter (buffer enable, buffer size, retry, enable) |
| I | Device assignment sequence |
| J | Device not ready (initial unit attention clearing) |
| K | Device reset |
| L | Device starting phase |
| M | Device in process of starting |
| N | Device block size determination |
| O | Device self-test |
| P | Device single block read (LBA) |
| Q | Device double block read (LBA) |
| S | Error occurred after device testing completed |
Please see the LEGAL - Trademark notice.