Symptom/Error | FRU/Action |
---|---|
Program-load error during | 1. Network Adapter |
remote IPL from the file | |
service. Displayed on upper | |
or lower half of the LCD. | |
External display screen | 1. External Display |
changes colors. | 2. Docking Frame |
One or more keys do not | 1. External Keyboard |
work on the external keyboard | 2. Keyboard Cable |
but the 3550 Expansion Unit | 3. System Board of 3550 Expansion Unit |
is otherwise functional. | |
(See | |
'Ext. Keyboard/Aux. Input Device Checkout'.) | |
Power-good light does | 1. System Board of 3550 Expansion Unit |
not turn on and fan runs. | 2. Power Supply |
Power-good light does | 1. Power Supply |
not turn on, fan does not | 2. System Board of 3550 Expansion Unit |
run, and 3550 Expansion | |
Unit is not functional. | |
(See 'Undetermined Problem'.) | |
Intermittent Failures. | 1. Power Supply |
(See 'Undetermined Problem'.) | 2. System Board of 3550 Expansion Unit |
3. Any Device or Adapter | |
3550 Expansion Unit | 1. System Board of 3550 Expansion Unit |
cannot be powered-off. | 2. Power Supply |
LED for hard disk drive | 1. SCSI Hard Disk Drive |
stays on. | 2. System Board of 3550 Expansion Unit |
LED for hard disk drive | 1. System Board of 3550 Expansion Unit |
is not working, but the | |
3550 Expansion Unit is | |
completely functional. |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.