Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Miscellaneous Symptoms (3550)



Miscellaneous Symptoms

Symptom/Error    FRU/Action
  
Program-load error during 1. Network Adapter
remote IPL from the file
service. Displayed on upper
or lower half of the LCD.
External display screen 1. External Display
changes colors. 2. Docking Frame
  
One or more keys do not 1. External Keyboard
work on the external keyboard 2. Keyboard Cable
but the 3550 Expansion Unit 3. System Board of 3550 Expansion Unit
is otherwise functional.
(See
'Ext. Keyboard/Aux. Input Device Checkout'.)
Power-good light does 1. System Board of 3550 Expansion Unit
not turn on and fan runs. 2. Power Supply
  
Power-good light does 1. Power Supply
not turn on, fan does not 2. System Board of 3550 Expansion Unit
run, and 3550 Expansion
Unit is not functional.
(See 'Undetermined Problem'.)
Intermittent Failures. 1. Power Supply
(See 'Undetermined Problem'.) 2. System Board of 3550 Expansion Unit
  3. Any Device or Adapter
  
3550 Expansion Unit 1. System Board of 3550 Expansion Unit
cannot be powered-off. 2. Power Supply
  
LED for hard disk drive 1. SCSI Hard Disk Drive
stays on. 2. System Board of 3550 Expansion Unit
  
LED for hard disk drive 1. System Board of 3550 Expansion Unit
is not working, but the
3550 Expansion Unit is
completely functional.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.