|001|
+---+
- Power-off the computer and all external devices.
- Check all cables and power cords.
- Make sure there are no diskettes in the drives.
- Power-on all external devices.
- Power-on the computer.
ARE ANY EXTERNAL DEVICES ATTACHED TO THE SYSTEM UNIT?
+---+
Yes No-+002| Go to Step 005
| +---+
+-+-+
|003|
+---+
DID THE POWER-GOOD LIGHT ON ALL OF THE EXTERNAL DEVICES COME ON ?
+---+
Yes No-+004| Go to the external devices service pamphlet.
| +---+
+-+-+
|005|
+---+
DID YOU RECEIVE A POST ERROR CODE ?
+---+
Yes No-+006| Continue with 014
| +---+
+-+-+
|007|
+---+
IS THE FIRST POST ERROR CODE WITHIN THE
RANGE OF 02080000 190I To 02410000 190I ?
+---+
Yes No-+008| Continue with Step 014
| +---+
+-+-+
|009|
+---+
- Start the Reference Diskette and verify that the Enable and
Disable settings are correct. (For more information,
go to 'Enable and Disable Settings'
- If you get a warning message to instruct you to Keep and
Remove setting, follow the instructions on the screen
before continuing.
DID YOU HAVE TO CORRECT ANY OF THE SETTINGS ?
+---+
Yes No-+010| Go to 'Symptom-to-FRU Index'
| +---+ - Before replacing any SCSI devices
| verify that there are no duplicate
+-+-+ SCSI ID settings.
|011|
+---+
- Remove the Reference Diskette and restart the computer.
DID THE ERROR REMAIN?
+---+
Yes No-+012| If you suspect another problem,
| +---+ or wish to run System Checkout,
+-+-+ continue with Step 014
|013|
+---+
Go to 'Symptom-to-FRU Index'
+---+
|014|
+---+
- Insert your Reference Diskette.
- Press Ctrl+Alt+Del and check for the
following responses:
1. One or two short beeps.
2. IBM logo screen appears.
DID YOU RECEIVE THE RESPONSES LISTED ABOVE ?
+---+
Yes No-+015| Go to 'Symptom-to-FRU Index'
| +---+ If that does not correct the problem,
+-+-+ go to 'Undetermined Problems'
|016|
+---+
- Advance to the Main Menu.
- Press Ctrl+A and run System Checkout.
NOTE:
1. If the computer has incorrect keyboard responses,
go to 'Ext. Keyboard/Aux. Input Device'
2. If the printer has incorrect responses, go to 'Printer Checkout'
3. If the external display has problems such as jittering, rolling,
shifting, or being out-of-focus, go to 'External Display Self-Test'
4. A minimum of 512KB of memory must be active
to load the diagnostic tests.
IS THE LIST OF INSTALLED DEVICES CORRECT ?
+---+
Yes No-+017| Go to 'Checking Installed Devices'
| +---+
+-+-+
|018|
+---+
- Run the diagnostic tests. (See 'How to Run Advanced Diagnostics')
NOTE: If the test stops and you cannot continue,
replace the last device being tested.
DID THE TESTS IDENTIFY A FAILURE ?
+---+
Yes No-+019| Go to Step 021
| +---+
+-+-+
|020|
+---+
Follow the action described on the screen.
If that does not correct the problem
go to 'Symptom-to-FRU Index'
-----------------------------------------------------------------------
DID YOU RECEIVE A POST ERROR CODE ?
+---+
Yes No-+022| You might have an intermittent problem.
| +---+
| ° Check for damaged cables and connectors.
| ° Reseat all adapters, drives, and modules.
| ° Check the system unit fan for proper operation.
| ° Start an error log and run the tests multiple times.
+-+-+ ° Go to 'Undetermined Problem'
|023|
+---+
Go to 'Symptom-to-FRU Index'
If that does not correct the problem, go to 'Undetermined Problem'
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.