IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
General Checkout
General Checkout
This general checkout procedure is for Netfinity 1000 - Type 8477 and
Netfinity 3000 - Type 8476 servers.
- Attention - The drives
in the system you are servicing might have been rearranged or the drive startup sequence
changed. Be extremely careful during write operations
such as copying, saving, or formatting. Data or
programs can be overwritten if you select an incorrect drive.
Diagnostic error messages appear when a test program
finds a problem with a hardware option. For the test
programs to properly determine if a test Passed, Failed , or
Aborted , the test programs check the error-return code at
test completion.
General error messages appear if a problem or conflict is
found by an application program, the operating system, or
both. For an explanation of these messages, refer to the
information supplied with that software package.
A failed system might be part of a shared DASD cluster
(two or more systems sharing the same external storage
device(s)). Prior to running diagnostics, verify that the
failing system is not part of a shared DASD cluster.
A system might be part of a cluster if:
- The customer identifies the system as part of a cluster.
- One or more external storage units are attached to
the system and at least one of the attached storage
units is additionally attached to another system or
unidentifiable source.
- One or more systems are located near the failing system.
If the failing system is suspect to be part of a shared
DASD cluster, all diagnostic tests can be run except
diagnostic tests which tests the storage unit (DASD
residing in the storage unit) or the storage adapter
attached to the storage unit.
Notes:
- For systems that are part of a shared DASD cluster, run one test at a time in looped mode.
Do not run all tests in looped mode, as this could enable the DASD diagnostic tests.
- Before replacing any FRUs, ensure the latest level of BIOS is installed on
the system. A down-level BIOS might cause false errors and unnecessary
replacement of the system board.
- If multiple error codes are displayed, diagnose the first error code displayed.
- If the server hangs with a POST error, go to
Symptom-to-FRU index.
- If the server hangs and no error is displayed, go to
Undetermined Problems.
- If an installed device is not recognized by the
diagnostics program, that device might be defective.
- Blank screen, unreadable screen, or other unusual response occurs, go to
Symptom-to-FRU Index.
- Power supply problems, see
Power Supply.
+---+
|001|
+---+
IS THE SYSTEM PART OF A CLUSTER?
Yes No
| |
| +-+-+
| |002| Go to Step 004.
| +---+
+-+-+
|003|
+---+
Schedule maintenance with the customer. Shut down all
systems related to the cluster. Run storage test.
------------------------------------------------------------------------
+---+
|004|
+---+
- Power-off the server and all external devices.
- Check all cables and power cords.
- Set all display controls to the middle position.
- Start the diagnostic programs, if necessary see
Running the Diagnostic Test Programs.
- Check for the following responses:
1. One or two beeps (depending on the diagnostics
version level).
2. Readable instructions or the Main Menu.
DID YOU RECEIVE THE CORRECT RESPONSES?
Yes No
| |
| +-+-+
| |005| Go to the Symptom-to-FRU index.
| +---+
+-+-+
|006|
+---+
ARE ALL INSTALLED DEVICES IN THE SERVER HIGHLIGHTED
ON THE MODULE TEST MENU OR HARDWARE CONFIGURATION REPORT?
Yes No
| |
| +-+-+
| |007| The missing device may be defective.
| +---+
+-+-+
|008|
+---+
Run the Advanced Diagnostics test. If necessary, refer to
Diagnostics.
- If you receive an error, go to Symptom-to-FRU Index.
- If the test stops and you cannot continue, replace the last device tested.