You are here because the diagnostic tests did not identify
the failure, the Devices List is incorrect, or the system is inoperative.
Note:
If you suspect a software mismatch is causing failures
(solid or intermittent), be sure to see
Configuration conflicts.
Check the power supply. If the LEDs indicate the power
supplies are working correctly, return here and do the
following:
Power-off the computer.
Remove or disconnect the following (one at a time)
until you find the failure (power-on the computer and
reconfigure each time):
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory-Module Kits (Minimum requirement = 1 bank of 32 MB DIMMs)
Note:
Minimum operating requirements vary for each computer.
Power-on the computer. If the problem remains,
suspect the following FRUs in the order listed:
System Board
Processor Board
Front Panel
Note:
If the problem goes away when you remove an adapter from the system,
and replacing that adapter does not correct the problem,
suspect the system board then the processor board(s).