| Code/Description | FRU/Action | 
|---|---|
| 00 | 1. See the system error log and follow the instruction for the error in the log. | 
| (POST failed) | |
| 01 | 1. See the system error log and follow the instruction for the error in the log. | 
| (POST warning) | |
| 08 | 1. See the system error log and follow the instruction for the error in the log. | 
| (Application failed) | |
| 09 | 1. See the system error log and follow the instruction for the error in the log. | 
| (Application warning) | |
| 10 | 1. Try to reboot the system. | 
| (Boot failed) | 2. See system error log for other possible errors. | 
| 18 | 1. Restart the server. | 
| (Operating system failed) | |
| 20 | 1. Clean out the error log. | 
| (Log full) | |
| 80 | 1. Ensure that all four fans are working. | 
| (Over temperature) | 2. Ensure the air intakes are clear. | 
| 3. Ensure the room temperature is not to hot (See User's Handbook). | |
| 4. Replace the following FRU for the temperature failure indicated in the error log: | |
| ° Ambient temperature, Front Panel | |
| ° Hard disk drive temperature, SCSI Backplane | |
| ° Processor temperature, Processor | |
| 85 | 1. See system error log to determine if there are any power supply or VRM errors. | 
| (Over voltage) | 2. Power Control Card | 
| 3. Processor Board | |
| 86 | 1. See system error log to determine if there are any power supply or VRM errors. | 
| (Low voltage) | 2. Power Control Card | 
| 3. Processor Board | |
| 90 | 1. Power Supply x | 
| (Power x) | 2. Power Control Card | 
| 98 | 1. See system error log to determine if there are any power supply or VRM errors. | 
| (Power system) | 2. Power Control Card | 
| A0 | 1. Fan X | 
| (Fan x, see | 2. Fan Cable | 
| ('Error Symptoms') | 3. Power Control Card | 
| B0 | 1. Ensure the covers are attached correctly. | 
| (Intrusion) | 2. Verify that there has been an intrusion into the system. | 
| 3. Intrusion Cable | |
| 4. Front Panel | |
| B8 | 1. Check the cable connection to the front panel. | 
| (Display) | 2. Front Panel Table | 
| C0 | 1. See the system error log and follow the instruction for the error in the log. | 
| (SMI error) | 2. Replace the FRU for the following problems listed. | 
| ° PCI related error: | |
| a. Adapter | |
| b. I/O Board | |
| ° Processor related error: | |
| a. Processor | |
| b. Processor Board | |
| ° Memory related error: | |
| a. DIMM | |
| b. Memory Board | |
| c. Processor Board | |
| C0 | 1. See system error log to determine which DIMM failed on which card. | 
| (Memory) | 