To use a terminal program to establish a connection with
the system management processor:
Baud 57.6 k (57600 bps)
Data Bits 8
Parity None
Stop Bits 1
Flow Control Hardware
Note:
The default username and password is case sensitive.
You must use all caps, and the '0' in PASSW0RD is the numeral zero.
2 Monitors
3 Error Logs
4 Service Processor Configuration
5 System Services
6 System Power
7 Boot
B Remote Terminal Status
Y Disconnect Current Logon
Z Start Remote Video
To access a menu item, press the number or letter that
corresponds to the information you want to access. After
you select a menu item, subsequent menus will offer more
specific information that pertains to the selection you made
from the main menu.
Note:
Menu Selection | Data Available for Viewing |
---|---|
Monitors | System board temperature, CPU temperatures, power supply temperatures, voltage readings, voltage regulator module readings, fan status, redundant power supply status. |
Error Logs | Contents of system error log |
Service Processor Configuration |
System management processor modem configuration, dial-out entries, dial-out alerts, dial-in logins, system status, thresholds, system statistics, VPD information and system state. |
System Services | Status of system management processor watchdog timers and event alerts sent to the server. |
System Power | Current system power status, power-off config. and power-off delay values. Note: You can use selections available from the System Power menu to power the system on or off. For more information, see 'System Power Menu Selections'. |
Boot | You can use selections available from the Boot menu to shutdown and restart the system mgmt. processor. For more information, see 'Boot Menu Selections' |
Remote Terminal Status |
Current remote terminal status |
Start Remote Video | Use Start Remote Video to enable the terminal program to remotely monitor and manage the server during POST. For more information, see 'Using Remote Video Mode to Monitor and access POST' |
When you are finished accessing the system management
processor using a terminal program, select Disconnect
Current Logon from the main menu and then use the
terminal program to close the connection to the system
management processor.
System Power Menu Selections: You can use the
selections available from the System Power menu to:
When you have established a connection with the
system management processor, you will be prompted
for a username and password.
You must provide a username and password combination that has been
username and password combination that has been
previously configured for use with the system
management processor. You can use one of two
username and password combinations:
The default username (USERID) and password (PASSW0RD)
Menu Selection | Data Available for Viewing |
---|---|
Service Processor Configuration |
System management processor modem configuration, dial-out entries, dial-out alerts, dial-in logins, system status, thresholds, system statistics, VPD information and system state System Services of system management processor watchdog timers and event alerts sent to the server System Power Current system power status, power-off configuration and power-off delay values. Note: You can use selections available from the System Power menu to power the system on or off. For more information, see 'System Power Menu Selections'. |
Boot | You can use selections available from the Boot menu to shutdown and restart the system or to restart the system management processor. For more information, see 'Boot Menu Selections'. |
Remote Terminal Status |
Current remote terminal status. |
Start Remote Video | Use Start Remote Video to enable the terminal program to remotely monitor and manage the server during POST. For more information, see 'Using Remote Video Mode to Monitor and Access POST'. |
System Power Menu Selections
You can use the selections available from the System Power menu to:
when you have established a connection with the system management processor, you will be promted for a username and password. You must provide a usename and password combination that has been previousely configured for use with the system management processor. You can use one of two username and password combinations:
The default username (USERID) and password (PASSW0RD)
A username and password that you define using the Advanced System Management service and Netfinity Manager
If you update the system management processor
microcode, the default username (USERID) and
password (PASSW0RD) are reset. If applicable,
notify the system administrator.
When you have logged into the system management processor, the following main menu appears:
2 Monitors
3 Error Logs
4 Service Processor Configuration
5 System Services
6 System Power
7 Boot
B Remote Terminal Status
Y Disconnect Current Logon
Z Start Remote Video
The following System Power menu appears:
1 Current Power Status
2 Power Configuration
3 Power On
4 Power Off
Boot Menu Selections: You can use the selections
available from the Boot menu to:
When you have established a connection with the system management processor, you will be prompted for a username and password. You must provide a username and password combination that has been previously configured for use with the system management processor. You can use one of two username and password combinations:
Note: The default username and password is case sensitive. You must use all caps, and the '0' in PASSW0RD, is the numeral zero.
If you update the system management processor
microcode, the default username (USERID) and
password (PASSW0RD) are reset. If applicable,
notify the system administrator.
When you have logged into the system management processor, the following main menu appears:
2 Monitors
3 Error Logs
4 Service Processor Configuration
5 System Services
6 System Power
7 Boot
B Remote Terminal Status
Y Disconnect Current Logon
Z Start Remote Video
The following Boot menu appears:
1 Reboot w/OS Shutdown
2 Reboot immediately
3 Restart SP
Please see the LEGAL - Trademark notice.