     IBM-AUSTRIA - PC-HW-Support    30 Aug 1999 | 
 
Hot-Swap Drive Installation (Netfinity 7000 - 8651)
Hot-Swap Drive Installation
The two banks of bays on the right front of the server
support hot-swap drives only.
  You do not have to power-off the server to install
hot-swap drives in these bays. However, you must
power-off the server when performing any steps that
involve installing or removing cables, except where
instructed to do so when you are replacing a hot-swap
fan. (See 'Hot-Swap Fan Replacement').
 
   -  Filler panel
   
 -  Hot swap hard disk drive
   
 -  Drive tray handle (open position)
 
To install a drive in a hot-swap bay, do the following:
   -  Unlock and open the server door.
  To maintain proper system cooling, do not
 operate the server for more than two minutes without either a drive or a
 filler panel installed in each bay.
   
 -  Remove the filler panel  -1-  from one of the empty
 hot-swap bays by inserting your finger into the
 depression at the left side of the filler panel and
 pulling it away from the server.
   
 -  Install the hard disk drive  -2-  in the hot-swap bay:
   -  Ensure the tray handle  -3-  is open (that is,
 perpendicular to the drive).
   
 -  Align the drive/tray assembly so that it engages
 the guide rails in the bay.
   
 -  Gently push the drive assembly into the bay until
 the drive connects to the backplane.
   
 -  Push the tray handle to the right until it locks.
 
   
 -  Check the hard disk drive status indicators to verify
 that the hard disk drives are operating properly. See
'Status Indicators' for details.
   
 -  Close and lock the server door.
   
 -  If the server has a RAID adapter installed, refer to the
 RAID adapter documentation for details about configuration requirements.
 
Back to  
More INFORMATION / HELP is available at the  IBM-HelpCenter
Please see the LEGAL  -  Trademark notice.
Feel free - send a 