     IBM-AUSTRIA - PC-HW-Support    30 Aug 1999 | 
 
5.25-Inch Removable-Media Drive (Netfinity 7000 - 8651)
5.25-Inch Removable-Media Drive
NOTE: The server's EMI integrity and cooling are both
protected by having the left front bays covered or
occupied. When you install a drive, save the filler
panel from the bay, in case you later remove the drive
and do not replace it with another.
 
   -  Screws
   
 -  Filler panel with EMI shield
   
 -  Slide rails
   
 -  Drive
 
To install a removable-media drive in one of the left front bays:
   -  Power-off the server and peripheral devices and
 remove the top cover (see 'Cover (Top)'
   
 -  Remove the media bay trim bezel, which covers the
 screws  -1-  on the bay filler panels  -2-
   -  Release the two tabs at the bottom edge of the
 bezel and pull the bottom of the bezel slightly
 away from the server.
   
 -  Pull the bezel down to release the two tabs at
 the top edge of the bezel. Set the bezel aside.
 
   
 -  Remove the screws  -1-  and filler panel  -2-  from the
 bay opening. Save the panel and screws for later use.
   
 -  Touch the static-protective bag containing the drive to
 any unpainted metal surface on the server, then,
 remove the drive from the bag and place it on a
 static-protective surface.
   
 -  Set any jumpers or switches on the drive according to
 the documentation that comes with the drive.
   
 -  Use screws of the appropriate size and length to
 attach a slide rail  -3-  to each side of the drive  -4-
NOTE: The slide rails and screws are included in the
 drive accessory kit that comes with the server.
   
 -  Place the drive so that the slide rails engage in the
 bay guide rails. Push the drive into the bay and
 attach it with the two screws  -1-  from the filler panel.
 
 1. Air baffle
 2. Shuttle-support rail
 3. Drive
 4. Opening in shuttle
 5. 4-drop SCSI cable
 6. SCSI ports A and B
 7. Screws
 8. Shuttle
   
 -  Loosen the four screws  -7-  on the shuttle at the back
 of the server.
   
 -  Pull the shuttle  -8-  toward the back of the server.
   
 -  Observe the way the edges of the air baffle  -1-  fit
 inside the shuttle-support rails  -2-, then, slide the air
 baffle toward the rear of the server and lift it out of the server.
   
 -  If you have not previously done so, install the 4-drop SCSI cable:
   -  Disconnect the SCSI cable from either SCSI port
 A or B  -6-  on the system board. (SCSI port A is
 connected to the hot-swap backplane for the
 right bank, Bank A, of hot-swap drives, and SCSI
 port B is connected to the hot-swap backplane
 for the left bank, Bank B, of hot-swap drives.
NOTE: If you disconnect the SCSI cable from SCSI
 port A, the server will not support drives in
 Bank A. If you disconnect the SCSI cable
 from SCSI port B, the server will not support drives in Bank B.
   
 -  Locate the 4-drop SCSI cable  -5-.  The 4-drop
 SCSI cable is shipped (disconnected) in the
 bottom of the server between the open bays and
 the power supply area. It is folded and
 restrained with a cable clamp.
   
 -  Open the cable clamp holding the 4-drop SCSI
 cable and route the prefolded cable through the
 opening  -4-  in the front of the shuttle.
   
 -  Connect the 4-drop SCSI cable to the vacant
 SCSI port  -6-  on the system (planar) board.
 
   
 -  Connect one of the connectors on the 4-drop SCSI
 cable to the back of the drive  -3-
   
 -  Connect a power cable to the back of the drive.
 Power cables for removable-media drives come
 installed in the server. The connectors are keyed and
 can be inserted only one way.
   
 -  If you are installing another 5.25-inch drive, do so at
 this time. Otherwise, continue with the next step.
  If the air baffle is not installed correctly, the
 server will overheat.
   
 -  Install the air baffle  -1-. Make certain that the edges
 of the air baffle fit inside the shuttle-support rails  -2-
   
 -  Push the shuttle  -8-  toward the front of the server
 and tighten the four screws  -7-  at the back of the shuttle.
   
 -  Install the bezel that you removed from the removable-media bay area:
   -  Insert the two tabs on the top of the bezel in the
 matching holes on the server.
   
 -  Push the bottom of the bezel toward the server
 until the two tabs at the bottom of the bezel snap into place.
 
 
Back to  
More INFORMATION / HELP is available at the  IBM-HelpCenter
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.