Symptom/Error | FRU/Action |
---|---|
10X | 1. System Board |
101 Interrupt failure | |
102 Timer failure | |
103 Timer interrupt failure | |
104 Protected mode failure | |
105 Last 8042 command- | |
-not accepted | |
107 NMI test failure | |
108 Timer bus test failure | |
109 Low meg-chip select test | |
110 | 1. Go to 'Memory Checkout' |
2. DIMM Card | |
3. The computer is attached to the expansion unit | |
4. System Board | |
111 | 1. Go to 'Memory Checkout' |
2. System Board | |
161 | 1. Go to 'Checking the Backup Battery' |
(Dead battery) | 2. Backup Battery |
3. System Board | |
163 | 1. Reseat the keyboard connector |
(Time and Date was not set.) | on the system board |
2. Set Time and Date | |
3. System Board | |
173 | 1. Reseat the keyboard connector |
(Configuration data were lost.) | on the system board |
2. Select OK in the error screen, | |
then set time and date. | |
3. Backup Battery | |
4. System Board | |
174 | 1. Check Device Configuration. |
Configuration error (Perform | 2. System Board |
'Checking the Installed Devices List' | 3. Diskette Drive Assembly |
before changing any FRUs.) | 4. Hard Disk Drive Assembly |
184 | 1. Reset the POP in Easy-Setup. |
(POP check sum error.) | |
190 | 1. Go to 'Checking the Battery Pack' |
(A depleted battery pack was | |
installed when the power was on.) | |
191XX | 1. System Board |
(PM initialzation error) | |
195 | 1. Check if the configuration |
(The configuration read from the | was changed |
hibernation area does not match | For example, check if the DIMM card |
the actual configuration.) | is added. |
196 | 1. Run the hard disk drive test |
(Read error occured in the | 2. Hard Disk Drive |
hibernation area of the HDD.) | |
1XX | 1. System Board |
2XX | 1. Go to 'Memory Checkout' |
201 Memory data error | 2. DIMM Card |
202 Memory line error 00-15 | 3. System Board |
203 Memory line error 16-23 | |
205 Memory test failure on | |
on-board memory | |
221 ROM to RAM remap error | |
301, 303, 304, 305, 3XX | 1. Go to 'Keyboard / Auxiliary Input Device Checkout' |
(Keyboard error) | 2. Keyboard |
3. External Numeric Keypad | |
4. External Keyboard | |
5. Keyboard/Mouse Cable | |
6. System Board | |
601, 6XX | 1. Go to 'Diskette Drive Test' |
(Diskette drive or | 2. Diskette Drive Assembly |
controller error.) | 3. Diskette |
4. System Board | |
602 | 1. Go to 'Diskette Drive Test' |
(Diskette read error.) | 2. Diskette |
3. Diskette Drive Assembly | |
604 | 1. Go to 'Diskette Drive Test' |
(Non-acceptable ID was read | 2. Diskette Drive Assembly |
from the diskette drive.) | 3. System Board |
11XX | 1. Serial Device (First) |
1101 Serial A test failure | 2. Communication Cable |
3. System Board | |
12XX | 1. System Board (Infrared) |
1101 Serial B test failure | |
17XX | 1. Hard Disk Drive |
1701 Hard sisk controller failure | 2. System Board |
1780, 1790 Hard disk 0 error | |
1781, 1791 Hard disk 1 error | |
24XX | 1. System Board |
2401 System board video error | |
808X | 1. PCMCIA Slot Assembly |
8081 PCMCIA presence test failure | 2. PCMCIA Device |
(PCMCIA revision also checked) | 3. System Board |
8082 PCMCIA register test failure | |
860X | 1. External Mouse |
(Pointing device error when | 2. External Keyboard |
TrackPoint III is disabled.) | 3. System Board |
8601 Systembus error- | |
8042 mouse interface | |
8602 External mouse error | |
8603 System bus error or | |
mouse error | |
861X | 1. Reseat the keyboard cable on |
(Pointing device error when | the systemboard. |
TrackPoint III is enabled.) | 2. Keyboard |
8611 System bus error-I/F between | 3. External Mouse |
8042 and IPDC | 4. System Board |
8612 TrackPoint error | |
8613 System board or TrackPoint error. | |
I9990301 | 1. Check that the operating system. |
I9990302 | is installed in the HDD. |
I9990305 | If not, install the operating system. |
I9990301 Hard disk error | 2. Reseat the boot device |
I9990302 Invalid hard disk boot | 3. Check the startup sequence for the correct |
record. | boot device. |
I9990305 No bootable device | 4. Check that the operating system has no |
failure and is installed correctly | |
I9990303 | 1. System Board |
Bank-2 flash ROM checksum error | |
Other codes not listed above | 1. Go to 'Undetermined Problems' |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.