Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Messages (2625)



Error Messages

Error Message/Symptom    FRU/Action
  
Bus Timeout NMI, 1. System Board
Slot .
Type (S)hut off NMI, (R)eboot,
other keys to continue.
Configuration for slot . 1. Run Setup Utility.
  
Diskette drive failure 1. See 'Diskette Drive Checkout'
  
Diskette drive failure 1. See 'Diskette Drive Checkout'
where =0 or =1.
Diskette read failure 1. Replace diskette with a bootable diskette and retry.
press F1 to retry boot (or may also say
F2 for Setup Utility).
Gate A20 failure 1. System Board
  
Hard disk configuration error 1. Correct the hard disk configuration.
  
Hard disk controller failure 1. System Board
  
Hard Disk failure 1. Hard Disk
  
Hard disk failure - 1. Check drive selection in setup.
press F1 to retry boot 2. Hard Disk.
(or may also say press F2
for Setup Utility).
F2 to enter ROM-based SETUP 1. Run Setup Utility.
  2. Verify Configuration.
  
ID information mismatch for slot 1. Run Setup Utility.
  
Invalid configuration information. 1. Run Setup Utility.
  
Internal cache test failed - 1. Processor Card
cache is disabled. 2. System Board
  
Keyboard clock line failure. 1. Keyboard cable and Keyboard connection.
  2. System Board
  
Keyboard controller failure. 1. System Board
  
Keyboard data line failure. 1. System Board
  
Keyboard is locked. 1. Unlock the Keyboard
  
Keyboard stuck key failure. 1. Locate and fix.
  2. Keyboard cable and Keyboard connection.
  3. System Board
  
Memory failure at hex-value,  1. RAM Memory Board
read hex-value , expecting hex-value .
No boot device available - 1. Diskette
press F1 to reboot 2. Diskette Drive
or press F2 for Setup Utility. 3. Hard Disk
  
No boot sector on hard disk. 1. Format the C drive.
Press F1 to reboot
or F2 for Setup Utility.
No fail safe timer NMI 1. System Board
  
No software port NMI 1. System Board
  
No timer tick interrupt 1. System Board
  
Not a boot diskette - 1. Replace diskette with a bootable diskette.
press F1 to reboot
or F2 for Setup Utility
Pointer device failure 1. Check cable connections
  2. Keyboard (TrackPoint)
  3. External Mouse
  
Real time clock failure 1. Run Setup Utility
  
Shutdown failure 1. Power-off, Power-on, Retry
  2. System Board
  
Time of day not set - 1. Run Setup Utility
run SETUP program
Timer 2 failure 1. System Board
  
Unexpected HW interrupt at address 1. System Board
Type (R)eboot, other keys to continue.
Hardware problem. Not displayed
if the extended interrupt handler
is not enabled.
Unexpected interrupt 1. System Board
in protected mode
Unexpected SW interrupt at address 1. System Board
Type (R)eboot, other keys to continue.
Error(s) in software program.
Not displayed if the
extended interrupt handler is not
enabled.
Unexpected type 02 interrupt 1. System Board
at xxxxxh
Type (S)hut off NMI,
(R)eboot, other keys to continue.
Parity error occurred.
Cause undetermined.
Unresolved BUS Timeout NMI, 1. System Board
Type (S)hut off NMI, 2. Processor Card
(R)eboot, other keys to continue.
Parity error occurred.
Cause undetermined.
Unresolved memory parity error 1. System Board
Type (S)hut off NMI, 2. SO-DIMM
(R)eboot, other keys to continue. 3. Optional Memory (8MB or 16MB Board)
Parity error occurred.
Cause undetermined.
xxxxx h Option ROM checksum failure 1. Power-off, Power-on, Retry
where xxxxx h is the 2. Peripheral Card
starting address of the option ROM


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.