Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes (9552)



Numeric Error Codes TP 700, 700C, 720, 720C (9552)

In the following error codes, an can be any number.

Symptom/Error    FRU/Action
  
00010200, 00010300, 1. System Board
00010400, 00010700
00010800 1. System Board
  2. Processor card
  
00011000 1. Go to 'Memory Checkout' before
      replacing any FRUs.
  2. Base Memory Card
  3. IC DRAM Card
  4. System Board
  
000113XX 1. System Board
  2. Processor Card
  
000118XX 1. Clear Error Log. See 'System Error Log'
  2. If the error remains, replace the FRUs
      in the following order:
      ° Base Memory Card
      ° IC DRAM Card
      NOTE: Error Log must be
      cleared when a FRU is replaced.
  
00016100 1. See 'Checking the Backup Battery'
  2. System Board
  3. Voltage Converter
  
00016300, 00016400, 1. Set Configuration/Features
00016500, 00016900 2. System Board
(If 00016300 appears, set date and 3. Hard Disk Drive
time first in the Reference Diskette.) 4. Base Memory Card
(If setting configuration does 5. IC DRAM Card
(not solve the problem, see
'Checking the Installed Devices List'
000171XX, 000172XX 1. System Board
  
00017300 1. See '173 and 11350 Error Combination'
(700, 700C Only) 2. See 'Checking the Backup Battery'
Before replacing a FRU, restore 3. Voltage Converter
the system partition with the
Ref.-Diskette V-1.1 or later.
See 'Installing a New Version
of the System Diskettes'
00017400 1. Set Configuration/Features
(If Automatic Configuration
does not solve the problem,
run Advanced Diagnostic.)
000175XX, 00017700 1. System Board
00017800
000179XX 1. Run System Unit and Memory Diagnostic.
      - or -
  2. Select More utilities to clear
      the system error log.
  
000183XX 1. PAP (Privileged Access Password)
      is needed to boot from the System Program.
  
000184XX, 00018500 1. System Board
  
000187XX 1. Set Configuration
  2. System Board
  
000188XX 1. System Board
  
000189XX 1. Select More utilities
      to clear the system error log.
  
00019000 1. Reseat System Board
  2. Reseat CPU chip / Processor Card
  3. System Board
  
00019102 1. Rerun diagnostics tests.
  2. If error remains, see 000191XX.
  
000191XX 1. Reseat System Board
(Not listed above) 2. Reseat CPU chip / Processor Card
  3. System Board
  
00019200 1. Voltage Converter
  2. Keyboard Control Card
  3. System Board
  
00019201 1. Voltage Converter
  
00019202 1. Run System Unit Diagnostic.
      If this error message appears frequently,
      replace the Processor Card.
  
00019300, 00019301 1. System Board
00019305
00019302 1. Hard Disk Drive
  2. System Board
  
00019303 1. System Board
  2. Diskette Drive
  
00019304 1. PC Card
  2. System Board
  
00019306 1. Keyboard Control Card
  2. Keyboard
  3. Pointing Device
  
00019400 1. Processor Card
  
000199XX 1. System Board
  
0001XXXX 1. System Board
(not listed above) 2. Processor Card
  
000215XX 1. Reseat Base Memory Card (interface
(720, 720C only)     connector on system board).
  
0002XXXX 1. Base Memory Card
(See 'Memory Checkout' 2. IC DRAM Card
before replacing any FRUs.) 3. System Board
  
.00030100, 00030500 1. Keyboard Control Card
(Power-on the computer) 2. System Board
(before external devices.) 3. Keyboard
(See '1080 Keyboard Unit' 4. Numeric Keypad or Keyboard/Mouse Cable
before replacing any FRUs.)     (if attached) - or -
      External Keyboard (if attached)
  
00030200, 00030300, 1. System Board
00030400 2. Keyboard Control Card
(See '1080 Keyboard Unit') 3. Numeric Keypad
before replacing any FRUs.)     or Keyboard/Mouse Cable (if attached)
      or External Keyboard (if attached)
  
00030600 1. Keyboard
(See '1080 Keyboard Unit' 2. Numeric Keypad or Keyboard/Mouse Cable
before replacing any FRUs.)     or External Keyboard (if attached)
  3. Keyboard Control Card
  4. System Board
  
00030700 1. External Keyboard
  2. Keyboard/Mouse Cable
  
0004XXXX 1. System Board
  2. Any Parallel Device
  3. Communication Cable
  
000601XX 1. Diskette Drive
  2. System Board
  3. Diskette Drive Cable
  
000602XX 1. Defective Diskette
  
000628XX 1. Incorrect Diskette Media Type
  2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
  
000655XX, 000662XX 1. System Board
000670XX - 000675XX 2. Diskette Drive
  3. Diskette Drive Cable
  
0006XXXX 1. Diskette Drive
(Unsupported drive or cable) 2. System Board
  3. Diskette Drive Cable
  
0007XXXX 1. Math Coprocessor
  2. Processor Card
  
0011XX00 1. System Board
  2. Any Serial Device
  3. Communication Cable
  
0014XXXX 1. See 'Printer Checkout'
      before replacing any FRUs.
  2. Printer
  3. System Board
  
00180100, 00186100 1. Replace the line
      QEMM386.SYS with
      QEMM386.SYS XBDA:L
      in Config.sys.
  
0024XX00 1. Video Card
  2. System Board
  3. Voltage Converter (700C, 720C only)
  
0039G900 1. System Board
  
005002XX, 005006XX, 1. See 'External Display Self-Test'
005008XX, 005041XX     before replacing any FRUs.
  2. Video Card
  3. External Display
  4. LCD
  5. System Board
  
005004XX, 005010XX, 1. Video Card
005030XX - 005032XX, 2. System Board
005051XX - 005062XX 3. LCD
  
005009XX, 005040XX 1. See 'External Display Self-Test'
      before replacing any FRUs.
  2. External Display
  3. Video Card
  4. System Board
  
0080XXXX 1. System Board
  2. PCMCIA Card Slot
  
0085XXXX 1. Do not replace any FRUs.
      The installed Memory Expansion Adapter
      is not supported by IBM.
  
00860100, 00860200 1. Pointing Device
(See '1080 Keyboard Unit' 2. System Board
before replacing any FRUs.) 3. Numeric Keypad
  
00860300, 00860400 1. System Board
00862300, 00862400 2. Keyboard Control Card
(See '1080 Keyboard Unit' 3. Pointing Device
before replacing any FRUs.) 4. Keyboard (TrackPoint)
  5. Numeric Keypad
  
00861100, 00861200 1. Keyboard Control Card
00861300 2. Keyboard (Pointing Stick)
(See '1080 Keyboard Unit' 3. System Board
before replacing any FRUs.) 4. Ext. Keyboard Cable
  
00861XXX 1. Keyboard (Pointing Stick)
(not listed above) 2. Keyboard Control Card
(See '1080 Keyboard Unit' 3. System Board
before replacing any FRUs.)
00862100, 00862200 1. Keyboard Control Card
(See '1080 Keyboard Unit' 2. System Board
before replacing any FRUs.) 3. Keyboard (TrackPoint)
  
00862500, 00862600 1. Keyboard (Pointing Stick)
(See '1080 Keyboard Unit' 2. Keyboard (TrackPoint)
before replacing any FRUs.) 3. Keyboard Control Card
  
c.0086XX00 1. Keyboard Control Card
(See '1080 Keyboard Unit' 2. Keyboard
before replacing any FRUs.) 3. System Board
  
010103XX - 010110XX, 1. See 'Fax/Modem Checkout'
010116XX - 010153XX,
010171XX
010436XX 1. System Board
  2. Hard Disk Drive
  
0104XXXX 1. Hard Disk Drive
  2. System Board
  
0129XXXX 1. Run System Board diagnostics
      to clear the error log and retest
  2. Select N to the question during
      the System Board diagnostics.
  3. Power-on the system. If the error
      remains, replace the Processor Card.
  4. Repeat steps 1 and 2.
  5. If the problem remains,
      replace the system board.
  
0130XXXX 1. Indicator Assembly
  2. System Board
  3. Keyboard Control Card
  4. Hard Disk Drive
  5. Diskette Drive
  6. Diskette Drive Cable
  7. Speaker
  
0137XXXX 1. Serial Adapter
  2. System Board
  3. Video Card
  4. Any Serial Device
  5. Communication Cable
  
0194XXXX 1. Do not replace any FRUs.
      The installed Memory Expansion Adapter
      is not supported by IBM.
  
I99903XX, I99900XX 1. Reseat the hard disk drive
I99800XX     to ensure good connection.
      See 'Set Startup Sequence'
  2. Hard Disk Drive
  3. System Board
  
I999XXXX 1. Restore the system partition
      from the Reference Diskette.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.