IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
173 and 11350 Error Combination (9552)
173 and 11350 Error Combination
If a POST error combination of 00017300 and 11350 appears and
cannot be bypassed, do the following before replacing any FRUs.
- Power-off the computer.
- Remove the hard disk drive from the computer.
- Insert the Reference Diskette and power-on the computer.
- Ignore any error messages, press Esc, F8,
and Enter, then run Automatic Configuration.
- Ignore the message An error occurred while updating config
and power-off the computer.
- Install the hard disk drive.
- Keep the Reference Diskette in drive A and power-on the computer.
- Ignore any error messages, press Y, and run Automatic
Configuration.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a