Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes (TP 600/600E - 2645)



  Numeric Error Codes

Symptom / Error    FRU / Action in Sequence
  
10x 1. System Board
101 Interrupt failure.
102 Timer failure.
103 Timer interrupt failure.
104 Protected mode failure.
105 Last 8042 command not accepted.
107 NMI test failure.
108 Timer bus test failure.
109 Low meg-chip select test.
110 1. Go to 'Memory Checkout'
(Planar parity.) 2. DIMM Card
  3. Detach the expansion unit if it is attached
      to the computer.
  4. System Board
  
111 1. Go to 'Memory Checkout'
(I/O parity.) 2. Expansion Unit or Port Replicator
  3. System Board
  
158 1. Set an HDPs for the hard disk drive.
(HDP was not set even though
the supervisor password is set.)
159 1. Set the correct password for hard disk drive.
(HDP is not set the same
as the supervisor password.)
161 1. Go to 'Checking the Backup Battery'.
(Dead battery.) 2. Backup Battery
  3. System Board
  
163 1. Set Time and Date
(Time and Date were not set.) 2. System Board
  
173 1. Select OK in the error screen,
(Configuration data was lost.)     then set the time and date
  2. Backup Battery
  3. System Board
  
174 1. Check Device Configuration.
(Configuration error: Perform 2. Hard Disk Drive
'Checking the Installed Devices List'. 3. System Board
before changing any FRUs.)
175, 177, 178 1. System Board
175 EEPROM CRC #1 error.
177 Supervisor password check sum error.
178 EEPROM is not functional.
17xx 1. Hard disk drive
1701: HDD controller failure 2. System board
1780, 1790 : HDD-0 error
1781, 1791 : HDD-1 error
183 1. Have the user examine the password.
(Incorrect password
entered at the supervisor
password prompt.)
184 1. Reset the POP (power-on password) in Easy-Setup.
(POP check sum error.)
185 1. Reset the startup sequence
(The startup sequence is not     in Easy-Setup.
valid. Suspect that power was
off when the startup sequence
was being updated.)
186 1. System Board
  
190 1. Go to 'Checking the Battery Pack'
(A depleted battery pack was
installed when the power was on.)
191xx 1. System Board
(PM initialization error.)
192 1. Fan
(Fan error.) 2. System Board
  
195 1. Check if the configuration was changed.
(The configuration read     For example, check if the DIMM is added
from the hibernation area
does not match the actual
configuration.)
196 1. Run the hard disk drive test.
(A read error occurred in the 2. Hard Disk Drive
hibernation area of the HDD.)
199xx 1. System Board
(Resume error.)
1xx 1. System Board
  
2xx 1. Go to 'Memory Checkout'.
201 Memory data error. 2. DIMM card
202 Memory line error 00-15. 3. System Board
203 Memory line error 16-23.
205 Memory test failure on on-board memory.
221 ROM to RAM remap error.
225 1. Check if the supported DIMM is installed
(Unsupported memory module) 2. DIMM card
 
3. System board
301, 303, 304, 305, 3xx 1. Go to 'Keyboard/Aux. Input Device Checkout'
(301: Keyboard error.) 2. Keyboard
  3. External Numeric Keypad
  4. External Keyboard
  5. Keyboard/Mouse Cable
  6. System Board
  
601, 6xx 1. Go to 'Diskette Drive Checkout'.
(601: Diskette drive 2. Diskette Drive assembly
or controller error.) 3. Diskette
  4. System Board
  
602 1. Go to 'Diskette Drive Checkout'.
(Diskette read error.) 2. Diskette
  3. Diskette Drive assembly
  
604 1. Go to 'Diskette Drive Checkout'.
(Unacceptable ID was read 2. Diskette Drive assembly
from the diskette drive.) 3. System Board
  
11xx 1. Serial Device
1101: Serial_A test failure. 2. Communication Cable
  3. System Board
  
12xx 1. System board (Infrared)
1101: Serial_B test failure.
17xx 1. Hard Disk Drive
1701 Hard disk controller failure. 2. System Board
1780, 1790 Hard disk 0 error.
1781, 1791 Hard disk 1 error.
24xx 1. System Board
(2401: System board video error.)
808x 1. PC Card slot assembly.
8081 PCMCIA presence 2. PCMCIA device
test failure. 3. System Board
(PCMCIA revision number
also checked.)
8082 PCMCIA register
test failure.
860x 1. External Mouse
(Pointing device error 2. External Keyboard
when TrackPoint is 3. System Board
disabled.)
8601 System bus error-8042
mouse interface.
8602 External mouse error.
8603 System bus error or mouse error.
861x 1. Reseat the keyboard cable.
(Pointing device error     on the system board.
when TrackPoint III is enabled.) 2. Keyboard.
8611 System bus error-I/F     cable on the keyboard card.
between 8042 and IPDC. 3. External mouse.
8612 TrackPoint error. 4. System board.
8613 System board or
TrackPoint error.
I9990301 1. Check that the operating system is
I9990302     installed in the HDD. If not, install
I9990305     the operating system.
I9990301 Hard disk error. 2. Reseat the boot device
I9990302 Invalid hard disk 3. Check the startup sequence for
boot record.     the correct boot device.
I9990305 No bootable device. 4. Check that the operating system has
      no failure and is installed correctly.
  
I9990303 1. System Board
(Bank 2 flash ROM check sum error.)
Other codes not listed above 1. Go to 'Undetermined Problems'.


More INFORMATION / HELP is available at the  IBM-HelpCenter