SONY CORPORATION
SDT-2000, SDT-4000
| Device Type | Tape Drive | 
| Interface | SCSI-2 | 
| Format | DDS, DDS-DC, DCLZ | 
| Sustained Transfer Rate | 183 KBPS (SDT-2000) 183-366 KBPS (SDT-4000) | 
| Size | 3.5 in. half height | 
| View | Top | 
 
| USER CONFIGURABLE SETTINGS | |||
| Setting | Label | Position | |
| » | Data compression disabled | JP1/Pins 7 & 8 | Closed | 
| Data compression enabled | JP1/Pins 7 & 8 | Open | |
| » | Parity enabled | JP1/Pins 9 & 10 | Closed | 
| Parity disabled | JP1/Pins 9 & 10 | Open | |
| » | Factory configured - do not alter. | JP1/Pins 11 & 12 | Unidentified | 
| » | Terminator enabled | JP1/Pins 13 & 14 | Closed | 
| Terminator disabled | JP1/Pins 13 & 14 | Open | |
| DRIVE SELECT ID | |||
| Drive ID | JP1/Pins 1 & 2 | JP1/Pins 3 & 4 | JP1/Pins 5 & 6 | 
| 0 | Open | Open | Open | 
| 1 | Open | Open | Closed | 
| 2 | Open | Closed | Open | 
| 3 | Open | Closed | Closed | 
| 4 | Closed | Open | Open | 
| 5 | Closed | Open | Closed | 
| 6 | Closed | Closed | Open | 
| 7 | Closed | Closed | Closed | 
| TERMINATION POWER SELECTION | ||
| Setting | JP1/Pins 15 & 16 | |
| » | TERMPWR supplied by drive | Closed | 
| TERMPWR supplied by SCSI interface to drive | Open | |
| MANUFACTURERS RECOMMENED MEDIA | |||
| Drive | Tape | Capacity Without Compression | Capacity With Compression | 
| SDT-2000 | DDS 90 meter | 2.0 GB | Unidentified | 
| SDT-4000 | DDS (DCLZ) 90 meter | 2.0-4.0 GB | 4.0-8.0 GB | 
 
| DIAGNOSTIC LED(S) | |||||
| LEDs | Functions | ||||
| LED1 | LED2 | LED3 | Activity | Cartridge | Other | 
| Off | Off | Off | None | None | None | 
| On | Off | Off | SCSI | None | None | 
| Flashing1 | Flashing1 | Off | Loading/Unloading | None | |
| Flashing1 | Flashing1 | On | Loading/Unloading | Write Protected | |
| Off | On | Flashing1 | None | Loaded | Cleaning Tape at EOM | 
| Off | On | Off | None | Loaded | None | 
| On | On | Off | SCSI | Loaded | None | 
| Flashing1 | On | Off | SCSI/Drive | Loaded | None | 
| Unidentified | On | On | X | Loaded | Write Protected | 
| Unidentified | Flashing2 | Unidentified | X | Loaded | Error Rate Warning | 
| Flashing2 | Unidentified | Unidentified | X | X | Humidity Warning | 
| Unidentified | Unidentified | Flashing2 | X | X | Cleaning Request | 
| Unidentified | Unidentified | Flashing3 | X | X | Drive Mechanism Failure | 
| Unidentified | Unidentified | Flashing4 | X | X | Drive Circuitry Failure | 
| Flashing3 | Unidentified | Unidentified | X | X | Waiting for Reset | 
| Unidentified | Flashing3 | Unidentified | X | X | Waiting for Eject | 
| Note:1 LED flashes at 0.25 seconds on/0.25 seconds off. 2 LED flashes at 3.5 seconds on/0.25 seconds off. 3 LED emits a continuous pulse at 0.25 seconds on. 4 LED emits a continuous double pulse at 0.25 seconds on. ‘X’ means not applicable. | |||||