IBM CORPORATION
OPTIONS 35/70 GB, DLT INTERNAL TAPE
| Device Type | Internal Tape Drive | 
| Interface | SCSI-2 Fast/Wide | 
| Format | DLT | 
| Sustained Transfer Rate | 5 MBPS, 10 MBPS | 
| Size | 5.25 in. third height | 
| View | Top | 
 
| USER CONFIGURABLE SETTINGS | |||
| Setting | Label | Position | |
| » | Factory configured - do not alter | JP1/Pins 1 & 2 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 3 & 4 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 5 & 6 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 7 & 8 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 9 & 10 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 11 & 12 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 13 & 14 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 15 & 16 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 17 & 18 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 19 & 20 | Unidentified | 
| » | Factory configured - do not alter | JP1/Pins 21 & 22 | Unidentified | 
| » | Termination enabled | JP1/Pins 23 & 24 | Closed | 
| Termination disabled | JP1/Pins 23 & 24 | Open | |
| » | Factory configured - do not alter | JP1/Pins 25 & 26 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 1 & 2 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 3 & 4 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 5 & 6 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 6 & 7 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 8 & 9 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 9 & 10 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 11 & 12 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 13 & 14 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 15 & 16 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 17 & 18 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 19 & 20 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 21 & 22 | Unidentified | 
| » | Factory configured - do not alter | JP2/Pins 23 & 24 | Unidentified | 
| » | Parity check disabled | JP2/Pins 25 & 26 | Open | 
| Parity check enabled | JP2/Pins 25 & 26 | Closed | |
| » | Factory configured - do not alter | JP4 | Unidentified | 
| DRIVE SELECT ID | ||||
| Drive ID | JP3/Pins 1 & 2 | JP3/Pins 3 & 4 | JP3/Pins 5 & 6 | |
| 0 | Closed | Open | Open | |
| » | 1 | Closed | Open | Open | 
| 2 | Closed | Open | Open | |
| 3 | Closed | Open | Open | |
| 4 | Closed | Open | Closed | |
| 5 | Closed | Open | Closed | |
| 6 | Closed | Open | Closed | |
| 7 | Closed | Open | Closed | |
| 8 | Closed | Closed | Open | |
| 9 | Closed | Closed | Open | |
| 10 | Closed | Closed | Open | |
| 11 | Closed | Closed | Open | |
| 12 | Closed | Closed | Closed | |
| 13 | Closed | Closed | Closed | |
| 14 | Closed | Closed | Closed | |
| 15 | Closed | Closed | Closed | |
| DRIVE SELECT ID (CONT’D) | |||
| Drive ID | JP3/Pins 7 & 8 | JP3/Pins 9 & 10 | |
| 0 | Open | Open | |
| » | 1 | Open | Closed | 
| 2 | Closed | Open | |
| 3 | Closed | Closed | |
| 4 | Open | Open | |
| 5 | Open | Closed | |
| 6 | Closed | Open | |
| 7 | Closed | Closed | |
| 8 | Open | Open | |
| 9 | Open | Closed | |
| 10 | Closed | Open | |
| 11 | Closed | Closed | |
| 12 | Open | Open | |
| 13 | Open | Closed | |
| 14 | Closed | Open | |
| 15 | Closed | Closed | |
| MANUFACTURERS RECOMMENDED MEDIA | ||
| Tape | Capacity Without Compression | Capacity With Compression | 
| IBM 59H3040 | 35GB | 70GB | 
| DLTtapeIII | 10GB | 20GB | 
| DLTtapeIIIxt | 15GB | 30GB | 
| DLTtapeIV | 35GB | 70GB | 
 
| DIAGNOSTIC LED(S) | |||
| LED | Color | Status | Condition | 
| LED1 | Orange | On | Cartridge is write protected | 
| LED1 | Orange | Off | Cartridge is not write protected | 
| LED2 | Yellow | On | Tape is loaded and ready for use | 
| LED2 | Yellow | Off | Tape is not loaded | 
| LED2 | Yellow | Blinking | Tape is in motion | 
| LED3 | Yellow | On | Tape is damaged | 
| LED3 | Yellow | Off | Tape is in perfect working condition | 
| LED4 | Green | On | You can safely lift the insert/release handle | 
| LED4 | Green | Off | Do not lift the insert/release handle | 
| LED4 | Green | Blinking | Push the insert/release handle down | 
| LED5 | Unidentified | On | Density Override indicator on | 
| LED5 | Unidentified | Off | Density Override indicator off | 
| LED6 | Unidentified | On | Compress indicator on | 
| LED6 | Unidentified | Off | Compress indicator off | 
| Note:LED’s 7 - 11 are capacity indicator lights, however, individual functions are unidentified. | |||