DATA TECHNOLOGY CORPORATION
DTC5250CX
| 
 | |
| Data bus: | 8-bit, ISA | 
| Size: | Full-length, full-height card | 
| Hard drive supported: | Two MFM ST506/412 drives | 
| Floppy drives supported: | Four 360KB, 720KB, 1.2MB, or 1.44MB drives | 
 
| CONNECTIONS | |
| Function | Location | 
| 34-pin control cable connector-floppy drive | J1 | 
| 34-pin control cable connector-hard drive | J2 | 
| 20-pin data cable connector - drive 0 | J3 | 
| 20-pin data cable connector - drive 1 | J4 | 
| 34-pin floppy drive cable connector - external | J5 | 
| USER CONFIGURABLE SETTINGS | |||
| Function | Location | Setting | |
| » | Floppy drive enabled | J6/jumper 3 | open | 
| Floppy drive disabled | J6/jumper 3 | closed | |
| » | Floppy drive B: 96 tracks per inch density enabled | J6/jumper 6 | closed | 
| Floppy drive B: 48 tracks per inch density enabled | J6/jumper 6 | open | |
| » | Floppy drive A: 96 tracks per inch density enabled | J6/jumper 7 | closed | 
| Floppy drive A: 48 tracks per inch density enabled | J6/jumper 7 | open | |
| USER CONFIGURABLE SETTINGS | |||
| Function | Location | Setting | |
| » | Floppy drive port address is 3F0-3F7h | SW2/switch 1 | off | 
| Floppy drive port address is 370-377h | SW2/switch 1 | on | |
| » | BIOS enabled | SW2/switch 3 | on | 
| BIOS disabled | SW2/switch 3 | off | |
| » | BIOS size 16KB | SW2/switch 4 | on | 
| BIOS size 8KB | SW2/switch 4 | off | |
| DRIVE TYPE SETTINGS - SW1/SWITCHES 1-8 | 
| For settings of SW1 see drive type settings table in document C0061 | 
| BIOS ADDRESS | |||||
| Address | SW2/switch 5 | SW2/switch 6 | SW2/switch 7 | SW2/switch 8 | |
| » | C800h | on | off | on | on | 
| D800h | on | off | off | on | |
| E800h | on | off | on | off | |
| MISCELLANEOUS TECHNICAL NOTES | 
| SW2/switch 2 is not used. If QIT01B1 EPROM is installed, jumper W1 must be closed, jumpers W2 and W3 must be open. The functions of J6/jumpers 1, 2, 4, 5, and 8 are undocumented. |