DISTRIBUTED PROCESSING TECHNOLOGY
PM2001B/90, PM2001B/95
| 
 | 
Data bus: 16-bit, ISA
Size: Full-lenght, full-height card
Hard drives supported: Up to seven SCSI devices (Enhanced Mode)
Floppy drives supported: PM2001B/90: None
PM2001B/95: Two 360KB, 720KB, 1.2MB, or 1.44MB
Sector interleave: 1:1
 
| CONNECTIONS | |
| Function | Location | 
| 4-pin connector-drive active LED | CN1 | 
| 34-pin data cable connector-floppy drive (PM2001/95 only) | CN8 | 
| 50-pin SCSI connector-internal | CN10 | 
| 50-pin SCSI connector-external | CN11 | 
| USER CONFIGURABLE SETTINGS | |||
| Function | Location | Setting | |
| » | Floppy drive port address 3F0-3F7h | JP5 | open | 
| Floppy drive port address 370-377h | JP5 | closed | |
| » | BIOS disabled | JP7 | open | 
| BIOS enabled | JP7 | closed | |
| » | Hard drive port address is 1F0-1F7h | JP17 | open | 
| Hard drive port address is 170-177h | JP17 | closed | |
| » | BIOS address is C800h | JP18 | open | 
| BIOS address is D800h | JP18 | closed | |
| » | Floppy drive enabled | JP20 | open | 
| Floppy drive disabled | JP20 | closed | |
| » | Floppy drive head load disabled | JP21 | open | 
| Floppy drive head load enabled | JP21 | closed | |
| INTERRUPT REQUEST | |||||
| IRQ | JP8 | JP9 | JP10 | JP22 | |
| Disabled | open | open | open | open | |
| » | 14 | closed | open | open | open | 
| 7 | open | closed | open | open | |
| 15 | open | open | closed | open | |
| 12 | open | open | open | closed | |
| SCSI ADDRESS | ||||
| SCSI I.D. | JP1 | JP2 | JP4 | |
| 0 | open | open | pins 1 & 2 open | |
| 1 | closed | open | pins 1 & 2 open | |
| 2 | open | closed | pins 1 & 2 open | |
| 3 | closed | closed | pins 1 & 2 open | |
| 4 | open | open | pins 1 & 2 closed | |
| 5 | closed | open | pins 1 & 2 closed | |
| 6 | open | closed | pins 1 & 2 closed | |
| » | 7 | closed | closed | pins 1 & 2 closed |