IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
NETFINITY 3500: SCO OPENSERVER INSTALL REQUIRES BIOS Flash
Subject: NETFINITY 3500: SCO OPENSERVER INSTALL REQUIRES BIOS Flash
Updated Netfinity server RETAIN TIP:
(Updated with BIOS 29A)
Record number: H163080
Device: D/T8644
Model: M
Hit count: UHC00005
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/03/16
Date last altered: A98/04/10
Owning B.U.: USA
Abstract: NETFINITY 3500: SCO OPENSERVER INSTALL REQUIRES BIOS FLASH
SYMPTOM:
The System hangs with the following displayed:
" F eiadinit
NOTICE: k_trap - Unexpected NMI in system mode! "
This occurs during the installation of SCO OpenServer 5.04
at the "Hardware Configuration" screen immediately after
the boot kernal has loaded into memory (ie: at the very
beginning of the installation).
PROBLEM ISOLATION AIDS:
- The System is a Netfinity 3500 Type 8644 model 10U, 10X,
20U, 20X, 21U, 21X, 30U, 30X being configured with SCO Open Server 5.04
- The System is at BIOS level 25A
- The System hardware is properly configured.
FIX:
- Download the "Netfinity 3500 BIOS flash update diskette
version 1.29 (revision 29) from the IBM Website at the
following URL:
http://www.pc.ibm.com/us/files.html
- Select "Search"
- Type "3500 BIOS" in the keywords box
- Select "Search"
- Select "Netfinity 3500 BIOS flash update diskette
version 1.29 (revision29)" to download.
The file is a self-extracting executable file that will
create a diskette. Be sure to label the diskette and
indicate BIOS level 29A.
- Place the BIOS flash update diskette in the diskette drive,
then power up the System.
- Follow the on-screen instructions to perform the BIOS Flash.
--DO NOT INTERRUPT THE SYSTEM DURING THE FLASH PROCEDURE--
- After the BIOS flash update is complete, remove the diskette,
and then press enter to reboot the System
- Install the SCO Open Server 5.04 Network Operating System.
SCO is a trademark of The Santa Cruz Operation, Inc.
OpenServer is a trademark of The Santa Cruz Operation, Inc.
Back to 
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.