|001|
+---+
- Insert the Diagnostics and Utilities CD into the CD/DVD-ROM Drive.
- Power-off the system unit.
- Ensure all DIMMs are seated correctly.
- Power-on the system unit.
- Note any messages, error codes, or symptoms.
DID YOU RECEIVE A 201 or 203 POST ERROR ?
Yes No
| +-+-+
| |002| DID YOU RECEIVE A 129 ERROR ?
| +---+ Yes No
| | +-+-+
| +-+-+ |003| Go to Step 006
| |004| +---+
| +---+
+-+-+ Replace the system board.
|005|
+---+
- Follow the screen instructions to run the Memory tests.
- If you cannot run the memory test or the test does not find a problem, use
the following procedure to find a failure.
- Replace each DIMM, one at a time, with a known-good DIMM of the same
size and type.
- I the problem goes away, the last DIMM replaced is defective. If all DIMM's
have been replaced and the problem remains, replace the system board.
+---+
|006|
+---+
- Follow the screen instructions to run the Memory tests.
DID THE MEMORY TESTS COMPLETE WITHOUT AN ERROR ?
Yes No
| +-+-+
| |007| - Replace each DIMM, one at a time, with a known-good DIMM
| +---+ of the same size and type.
| - If the problem goes away, the last DIMM replaced is defective.
| If all DIMMs have been replaced and the problem remains,
+-+-+ replace the system board.
|008|
+---+
- The system memory is now functioning correctly. If you suspect an
intermittent problem, run the Memory and System board tests multiple
times.