| 
    | 
 
| Error Code | FRU/Action. | 
|---|---|
| 0002 | 1. Cables | 
| (Primary boot device not found) | 2. Primary Boot Device | 
| 0010 | 1. Processor Module | 
| (Cache memory failure, | 2. Processor Board | 
| do not enable cache) | |
| 0015 | 1. Primary Output Device | 
| (Primary output device | |
| not found) | |
| 0016 | 1. Primary Input Device | 
| (Primary input device | |
| not found) | |
| 0041 | 1. Reseat EISA Adapter | 
| (EISA ID mismatch for slot) | 2. Run SCU program | 
| 3. EISA Adapter | |
| 0043 | 1. Reseat EISA Adapter | 
| (EISA invalid configuration | 2. Run SCU program | 
| for slot) | |
| 0044 | 1. Reseat EISA Adapter | 
| (EISA configuration not assured) | 2. Run SCU program | 
| 0045 | 1. Reseat EISA Adapter | 
| (EISA expansion board not | 2. EISA Adapter | 
| ready in slot) | 3. System Board | 
| 0047 | 1. Run SCU program | 
| (EISA CMOS configuration not set) | 2. EISA Adapter | 
| 3. System Board | |
| 0048 | 1. Run SCU program | 
| (EISA CMOS checksum failure) | 2. System Board | 
| 0049 | 1. Run SCU program | 
| (EISA NVRAM invalid) | 2. System Board | 
| 0060 | 1. Unlock keyboard | 
| (Keyboard is locked - | 2. Keyboard | 
| - please unlock it) | 3. System Board | 
| 0070 | 1. Set time and date | 
| (CMOS time and date not set) | 2. Real-Time Clock Module | 
| 0080 | 1. Reseat adapter | 
| (Option ROM has bad checksum) | 2. Adapter | 
| 0083 | 1. Reseat adapter | 
| (Shadow of PCI ROM failed) | 2. Adapter | 
| 0084 | 1. Reseat adapter | 
| (Shadow of EISA ROM failed) | 2. Adapter | 
| 0085 | 1. Reseat adapter | 
| (Shadow of ISA ROM failed) | 2. Remove adapter | 
| 0131 | 1. Cable | 
| (Floppy Drive A:) | 2. Drive | 
| 0132 | 1. Cable | 
| (Floppy Drive B:) | 2. Drive | 
| 0135 | 1. System Board | 
| (Floppy disk controller | |
| failed) | |
| 0140 | 1. Reboot system | 
| (Shadow of system BIOS | 2. System Board | 
| failed) | |
| 0171 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 1, CPU # 1) | 3. Processor Board | 
| 0172 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 1, CPU # 2) | 3. Processor Board | 
| 0173 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 2, CPU # 1) | 3. Processor Board | 
| 0174 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 2, CPU # 2) | 3. Processor Board | 
| 0175 | 1. Use compatible processor modules | 
| (CPU modules are | |
| incompatible) | |
| 0176 0178 0180 | 1. see FALSE CPU FAILURE AT POST | 
| 0177 0179 0181 | |
| 0180 | 1. Processor Module | 
| (Attempting to boot | |
| with failed CPU) | |
| 0191 | 1. Real-Time Clock Module | 
| (CMOS battery failed) | 2. System Board | 
| 0195 | 1. Run SCU program | 
| (CMOS system options not set) | |
| 0198 | 1. Run SCU program | 
| (CMOS checksum invalid) | |
| 0289 | 1. Run System Setup | 
| (System memory size mismatch) | 2. Memory SIMM | 
| 3. Memory Board | |
| 0295 | 1. Memory SIMM | 
| (Address line short detected) | 2. Memory Board | 
| 0297 | 1. Run System Setup | 
| (Memory size decreased) | 2. Memory SIMM | 
| 3. Memory Board | |
| 0299 | 1. Reseat memory and memory board | 
| (ECC error correction failure) | 2. Memory Board | 
| 3. System Board | |
| 0301 | 1. Reseat memory and memory board | 
| (ECC single bit correction | 2. Memory Board | 
| failed, correction disabled) | 3. System Board | 
| 0302 | 1. Reseat memory and memory board | 
| (ECC double bit error) | 2. Memory Board | 
| 3. System Board | |
| 0310 | 1. Reseat memory and memory board | 
| (ECC address failure | 2. Memory Board | 
| 3. System Board | |
| 0370 | 1. Reboot system | 
| (Keyboard controller error) | 2. System Board | 
| 0373 | 1. Ensure nothing is resting on the keyboard | 
| (Keyboard stuck key detected) | 2. Keyboard | 
| 0375 | 1. Swap keyboard and mouse | 
| (Keyboard and mouse swapped) | |
| 0380 | 1. Replace memory as indicated | 
| (ECC SIMM failure, | |
| board is in slot 1) | |
| 0392 | 1. Replace memory as indicated | 
| (ECC SIMM failure, | |
| board is in slot 2) | |
| 0430 | 1. System Board | 
| (Timer channel 2 failure) | |
| 0440 | 1. System Board | 
| (Gate-A20 failure) | |
| 0441 | 1. Use correct device driver | 
| (Unexpected interrupted | |
| in protected mode) | |
| 0445 | 1. System Board | 
| (Master interrupt controller | |
| error) | |
| 0446 | 1. System Board | 
| (Slave interrupt controller | |
| error) | |
| 0450 | 1. System Board | 
| (Master DMA controller error) | |
| 0451 | 1. System Board | 
| (Slave DMA controller error) | |
| 0460 | 1. Adapter | 
| (Fail-safe timer NMI failure) | 2. System Board | 
| 0461 | 1. Check software/device driver | 
| (Software port NMI failure) | |
| 0465 | 1. Check adapter | 
| (Bus timeout NMI in slot) | 2. Adapter | 
| 3. System Board | |
| 0467 | 1. Check adapter | 
| (Expansion board NMI in slot) | 2. Adapter | 
| 0501 | 1. System Board | 
| (PCI system error) | 2. Adapter | 
| 0510 | 1. PCI device | 
| (PCI parity error) | 2. System Board | 
| 0710 | 1. Run SCU program | 
| (System board device | |
| resource conflict) | |
| 0711 | 1. Run SCU program | 
| (Static device resource | |
| conflict) | |
| 0800 | 1. Run SCU program | 
| (PCI I/O port conflict) | |
| 0801 | 1. Run SCU program | 
| (PCI memory conflict) | |
| 0802 | 1. Run SCU program | 
| (PCI IRQ conflict) | |
| 0803 | 1. Rerun diagnostics | 
| (PCI error log is full, | |
| the log will be cleared | |
| automatically) | |
| 0810 | 1. Run SCU program | 
| (Floppy disk controller | |
| resource conflict) | |
| 0811 | 1. Check cables | 
| 2. System Board | |
| 0812 | 1. Check cables | 
| 2. System Board | |
| 0815 | 1. Run SCU program | 
| (Parallel port resource | |
| conflict) | |
| 0816 | 1. Run SCU program | 
| (Serial port 1 resource | |
| conflict) | |
| 0817 | 1. Run SCU program | 
| (Serial port 2 resource | |
| conflict) | |
| 0820 | 1. Run SCU program | 
| (Expansion board disabled | 2. Adapter | 
| in slot) | 3. System Board | 
| 0900 | 1. Run SCU program | 
| (NVRAM checksum error, | |
| NVRAM cleared) | |
| 0903 | 1. Run SCU program | 
| (NVRAM DATA invalid, | |
| NVRAM cleared) | |
| 0905 | 1. Run SCU program | 
| (NVRAM cleared by jumper) | |
| 0960 | 1. see FALSE CPU FAILURE AT POST | 
| Watchdog Timeout has occurred | |
| 0982 | 1. Adapter | 
| (I/O expansion board | 2. System Board | 
| NMI in slot) | |
| 0984 | 1. Run SCU program | 
| (Expansion board disabled | 2. Adapter | 
| in slot) | 3. System Board | 
| 0985 | 1. Adapter | 
| (Fail-safe timer NMI) | 2. System Board | 
| 0986 | 1. Adapter | 
| (System reset caused | 2. System Board | 
| by Watchdog Timer) | |
| 0987 | 1. Adapter | 
| (Bus timeout NMI in slot) | 2. System Board | 
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.