   DDDD DDS0 VVVVIIII
   ------+|| ---+---+
         |||    |   +--PCI Device ID
         |||    +------PCI Vendor Number
         ||+-Reserved (usually 0)
         |+PCI Slot Number (0 = System board)
         +-PCI Device Error
For example, PCI error code 005A210vvvviiii decodes as follows:
   005A 02   PCI device disabled due to Built-in Self Test failure
   1         The device is in PCI slot number one.
   0         Reserved.
   vvvv      Could be any number (PCI vendor ID)
   iiii      Could be any number (PCI device ID)
PCI Error Codes 
| Error Code | FRU/Action | 
|---|---|
| 00900100vvvviiii | 1. System Board | 
| (System board PCI device | |
| does not respond) | |
| 009002s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI device Built-in Self | - or - | 
| Test failure) | If S = 0, replace the system board. | 
| 009003s0vvvviiii | 1. Run the PCI Utility or the Micro Channel | 
| (PCI device resource allocation | Change Configuration Utility to change | 
| failure. No resource available | system resource allocation. | 
| for the requested memory, I/O, | |
| or C0000-DFFFF ROM addr. space) | |
| 009004s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI device ROM checksum | - or - | 
| failure) | If S = 0, replace the system board. | 
| 009005s0vvvviiii | 1. Remove the unsupported PCI adapter | 
| (Unsupported PCI device) | |
| 009010s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI data parity error) | - or - | 
| If S = 0, replace the system board. | |
| 009011s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI data parity error) | - or - | 
| If S = 0, replace the system board. | |
| 009020s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI addr. parity error) | - or - | 
| If S = 0, replace the system board. | |
| 009030s0vvvviiii | 1. If S <> 0, replace the PCI adapter. | 
| (PCI system error) | - or - | 
| If S = 0, replace the system board. | 
PCI Error Messages 
| Error Message | FRU/Action | 
|---|---|
| PCI device(s) removed | 1. One or more PCI add-in devices | 
| since last power up: | appears to have been removed since | 
| PCI vendor ID=xxxx, device | the last execution of POST | 
| ID=xxxx previously in slot x | This could be due to a catastrophic | 
| failure of the PCI device rather than its | |
| actual physical removal. | |
| PCI device(s) added | 1. One or more PCI add-in devices | 
| since last power up: | appears to have been added since | 
| PCI vendor ID=xxxx, device | the last execution of POST | 
| ID=xxxx previously in slot x | It may have been moved from | 
| another slot. This is not an error. | |
| The device was enabled and had resources assigned. | |
| Unable to assign requested | 1. A requested PCI resource (from the | 
| resources: | PCI Device Configuration Block) could not | 
| PCI vendor ID=xxxx, device | be assigned as requested due to a conflict | 
| ID=xxxx in slot x | with a non-PCI device or to a conflict with | 
| another requested PCI resource | 
Please see the LEGAL  -  Trademark notice.
Feel free - send a 