| Check/Verify | FRU/Action |
|---|---|
| 1. Verify that the voltage-selector switch is set for the correct voltage. |
Correct the voltage-selector switch setting. |
| 2. Check the following for proper installation. Power Cord On/Off Switch connector On/Off Switch Power Supply connector System Board Power Supply connectors |
Reseat |
| 3. Check the power cord for proper continuity. |
Power Cord |
| 4. Check the power-on switch for continuity. |
Power-on Switch |
If these are correct, check the following voltages.
System Board Connections (P1 / P2 and P11)
NOTE:
These voltages must be checked with the power
supply cables connected to the system board.
If the voltages are not correct, and the power cord is good, replace the
power supply.
If the voltages are correct, and the computer you are servicing has a
power supply connector on the riser card, check the following riser
card voltages.
Riser Card Connections (P10)
NOTE:
These voltages must be checked with the power
supply cable connected to the riser card.
If the voltages are not correct, and the power cord is good, replace the
power supply.
Please see the LEGAL - Trademark notice.