IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Restoring the Partition (8554)
Restoring the Partition
If a computer or hard disk problem prevents system setup or diagnostic
programs from being loaded from the protected partition,
load and run the programs from the Reference Diskette.
If no errors are found, restore the programs to the protected partition
on the hard disk using the following procedure.
- Start the computer with the customer's backup
copy of the Reference Diskette installed.
- Select the Backup/Restore system programs from the
Main Menu.
- Select the Restore the system partition to
load the system setup and utility programs, and
the customer and advanced diagnostics
programs onto the system partition of the hard disk.
If this does not correct the problem, use the backup copy of the
Reference Diskette to
format the hard disk and then restore the programs to the
protected partition.
If the problem remains, return to the
I998XXXX, I9990303 error code (in the 'Symptom-to-FRU Index')
NOTE:
After the programs have been restored, the Diskette and F1 prompts
appear, unless an operating system is present.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.