IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Restoring the Partition (8551)
Restoring the Partition
If a computer or hard disk problem prevents system setup or diagnostic
programs from being loaded from the protected partition,
load and run the programs from the Reference Diskette.
If no errors are found, restore the programs to the protected partition
on the hard disk using the following procedure.
- Start the computer with the customer's backup copy of the Reference
Diskette installed.
NOTE:
The languages of the Reference Diskette and the computer must
match.
- Select 2. Backup/Restore system programs
from the Main Menu.
- Select 3. Restore the system partition
to load the system setup and utility programs, and the customer and advanced
diagnostic programs onto the system partition of the hard disk.
If this does not correct the problem, use the backup copy of the
Reference Diskette to
format the hard disk and then restore the programs to the
protected partition.
If the problem remains, return to the
I998XXXX, I9990303
error code (in
the 'Symptom-to-FRU Index').
NOTE: After the programs have been restored, the Insert-Diskette
icon appears, unless an operating system is present.
Back to 
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.