Pin | Voltage (Vdc) |
---|---|
1 | +3.0 to +4.5 |
2 | Ground |
If the voltage is correct, perform the failing operation with a fully-charged standby battery to isolate the problem.
If the voltage is not correct, continue.
If the voltage is higher than measured in Step 3, the standby battery is discharged or is defective.
If the voltage is the same as measured in Step 3. or less than +3.0 Vdc, replace the standby battery. If the problem remains, replace the system board.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.