| Symptom/Error: | FRU/Action. |
|---|---|
| 00010000 | 1. System Board |
| 0001500X | 1. Perform the Update Firmware |
| procedure. (Firmware update | |
| was not completed.) | |
| 2. System Board | |
| 0001550X | 1. System Board |
| 00016000 | 1. Battery |
| 2. System Board | |
| 00016002 | 1. System Board |
| 00016003 | CMOS locked during set/reset |
| unattended mode. This procedure | |
| must be done when computer is | |
| first powered on. | |
| 1. Power off computer | |
| 2. Power on and load System | |
| Management Services Diskette | |
| 3. Set or reset unattended mode. | |
| 00016004 | CMOS locked when attemting to |
| set or reset Supervisor password. | |
| This procedure must be done when | |
| computer is first powered on. | |
| 1. Power off computer | |
| 2. Power on and load System | |
| Management Services Diskette | |
| 3. Set or reset Supervisor password. | |
| 00016005 | CMOS locked when attemting to |
| set or reset Power on password. | |
| This procedure must be done when | |
| computer is first powered on. | |
| 1. Power off computer | |
| 2. Power on and load System | |
| Management Services Diskette | |
| 3. Set or reset Power on password. | |
| 00016006 | Supervisory password CRC bad |
| 1. Battery | |
| 2. System Board | |
| 00017001 00017002 | 1. Battery |
| 2. System Board | |
| 00017003 | Boot sequence bad, reselect |
| Boot Sequence from SMS diskette | |
| If problem persists: | |
| 1. Battery from SMS diskette | |
| 2. System Board | |
| 00017006 | Tamper evident or new battery. |
| 1. The battery was tampered with. | |
| or a new battery has been | |
| installed, reconfigure ROM with | |
| date, time, password and | |
| configuration information | |
| 00017007 00017008 | Computer stopping maximum number of |
| password attempts reached. | |
| 1. Verify password with customer. | |
| 2. Turn the computer power off and | |
| then on. | |
| 3. Retry password. If the correct password | |
| is unknown, the CMOS must be cleared, | |
| see 'Removing a Power on Password' | |
| 00017013 | Power on Password not entered, |
| unattended mode can not be set, set | |
| password and then set unattended mode. | |
| 00018000 | Flash ROM image bad |
| 1. Recover Flash or Reflash | |
| system board | |
| 2. System Board | |
| 00020000 | 1. See 'Memory' |
| 000210X0 | 1. See 'Memory' |
| 2. Memory Module | |
| 3. System Board | |
| 000300XX | 1. Keyboard |
| NOTE: If XX is 50, you might | |
| have pressed a key during testing. | |
| Rerun the test. If the problem. | |
| persists, replace the keyboard. | |
| 2. System Board | |
| 00031100 | 1. Keyboard plugged into wrong port |
| (mouse port) | |
| 00031200 | 1. Keyboard not attached, attach |
| keyboard | |
| 2. Keyboard Cable | |
| 3. Keyboard | |
| 4. System Board | |
| 00061XX0 | 1. System Board |
| 2. Diskette Drive | |
| 00062XX0 | 1. Diskette Drive |
| 2. Diskette Drive Cable | |
| 3. System Board | |
| 00063XX0 | 1. Diskette Media |
| 2. Diskette Drive | |
| 3. Diskette Drive Cable | |
| 4. System Board | |
| 0011XXXX | 1. System Board |
| 0014XXXX | 1. See 'Printer' |
| 0017XXXX | 1. EIDE Device |
| 2. EIDE Cable | |
| 3. System Board | |
| 0037XXX0 | 1. see SCSI Symptoms and Error Codes |
| 008600XX | 1. Mouse |
| NOTE: If XX is 50, you might | |
| have moved the mouse during testing. | |
| Rerun the test. If the problem. | |
| persists, replace the mouse. | |
| 2. System Board | |
| 01291000 | 1. L2 Cache Memory |
| 2. System Board | |
| 0166XXXX | 1. ISA Token Ring Adapter |
| 0208XXXX to 0209XXXX | 1. see SCSI Symptoms and Error Codes |
| 0210XXXX to 0219XXXX | 1. see SCSI Symptoms and Error Codes |
| 02430250 | 1. Video Adapter |
| 2. Riser Card | |
| 3. System Board | |
| 0250100X | 1. System Board |
| 0265XXXX | 1. ISA Ethernet Adapter |
| 0267XXXX | 1. System Board |
| (PCI Ethernet Controller) | |
| 0849XXXX | 1. ISA X.25 Adapter |
| 0942042X | 1. Video Adapter |
| 2. Riser Card | |
| 3. System Board | |
| 50001100 | 1. Firmware does not match System |
| Management Service diskette, update | |
| system firmware | |
| 5333000X | 1. Video Adapter |
| 2. Riser Card | |
| 3. System Board |