FRU P/N 08H3737 MC Serial Infrared Adapter
OPT P/N 08H3655 MC Serial Infrared Adapter Option (OWIEASY)
FRU P/N 08H3736 ISA Serial Infrared Adapter
OPT P/N 08H3654 ISA Serial Infrared Adapter Option (OWIVASY)
FRU P/N 08H3738 PCMCIA Serial Infrared Adapter
OPT P/N 08H3656 PCMCIA Serial Infrared Adapter Option (OWINASY)
FRU P/N 08H3739 Infrared Transceiver for ISA / MC
FRU P/N 08H3740 Infrared Transceiver for PCMCIA
The Option Adapter package contains:
+--RESERVED must be set to 0 (OFF position)
|
| +--- 1 = IRQ 10 *)
| | 0 = IRQ 15
------+ |
Switch # -- 1 2 3 4 5 6 7 8
| | | | Memory Addr. I/O-Addr.
( 1 1 1 1 C0000 300 ) Do NOT USE
( 0 1 1 1 C2000 300 ) for PS/1
( 1 0 1 1 C4000 320 ) Computers
0 0 1 1 C6000 320
1 1 0 1 C8000 340
0 1 0 1 CA000 340
1 1 1 0 D0000 300 *)
0 1 1 0 D2000 300
1 0 1 0 D4000 320
0 0 1 0 D6000 320
1 1 0 0 D8000 340
0 0 0 0 DA000 340
Factory setting = *) Switch OFF = 0 / ON = 1
| Message | Meaning |
|---|---|
| Serial Infrared Adapter not detected | Check Configuration (EMM386) if PCMCIA |
| Card, check socket driver for PCMCIA. Also | |
| maybe that adapter is used by another appl. | |
| Could not allocate requested memory | A sufficiently 8KB memory area is not avail. |
| address range from Card Services | in the I/O space being used by Card & Socket |
| Services. | |
| Could not allocate requested I/O | A sufficiently 32Byte I/O area is not avail. |
| address range from Card Services | in the I/O space being used by Card & Socket |
| Services. | |
| Could not allocate requested IRQ line | The IRQ's requested for use by Card Services |
| from Card Services | are not available. |
| Could not gain exclusive use of the | Other software is already using the adapter |
| adapter from Card Services | |
| Could not configure the adapter with | There is an I/O address or IRQ conflict |
| Card Services | between adapters. |
Micro Channel Diagnostics Error Messages
| Message | Meaning |
|---|---|
| The Serial Infrared Adapter diagnostic | The Adapter is defective |
| detected an internal error | |
| The Memory test of the Serial Infrared | There is a memory conflict between the adapter |
| Adapter failed | memory and another application (EMM386) |
| The internal test of the Serial | There is an I/O conflict between the Serial |
| Infrared Adapter failed | Infrared Adapter and another Adapter. |
| The Serial Infrared Adapter | There is an I/O conflict between the Serial |
| SDLC Controller test failed | Infrared Adapter and another Adapter. |
| The Serial Infrared Adapter | There is an I/O conflict between the Serial |
| UART Controller test failed | Infrared Adapter and another Adapter. |
Please see the LEGAL - Trademark notice.
Feel free - send a