Error Code/Symptom | FRU/Action |
---|---|
0000 | 1. Be sure the adapter Device |
SCSI Adapter not enabled. | and Bus Master fields are enabled |
in the PCI configuration program. | |
Refer to the documentation that | |
was shipped with the computer. | |
002X | 1. SCSI Adapter |
008X | 1. Check SCSI terminators for |
Check for proper installation | proper installation |
of SCSI terminators. | 2. SCSI Cable |
3. SCSI Terminator | |
4. SCSI Device | |
5. SCSI Adapter | |
0115 | 1. System Board |
Protected mode cannot be enabled. | |
0164 | 1. Run Setup and ensure |
POST detected a base memory or expansion | the memory size is correct |
memory size mismatch | 2. Run the Expanded |
Memory Diagnostic tests. | |
0601 | 1. Set Configuration |
Diskette configuration error | |
0610 | 1. Diskette Drive |
Cannot find diskette controller | 2. Diskette Drive Cable |
for drive A. | 3. Diskette Drive Adapter if installed |
4. System Board | |
0612 | 1. Diskette Drive |
Cannot find diskette controller | 2. Diskette Drive Cable |
for drive B. | 3. Diskette Drive Adapter if installed |
4. System Board | |
0616 | 1. Diskette Drive Adapter |
Diskette drive reset failed. | |
0632 | 1. Diskette Drive A |
Diskette drive 0 seek failure | |
0642 | 1. Diskette Drive B |
Diskette drive 1 seek failure | |
0653 | 1. Format diskette |
Diskette not formatted or defective | 2. Diskette |
0655 | 1. Diskette Drive |
Diskette drive controller failed. | 2. Diskette Drive Cable |
3. Diskette Drive Adapter if installed. | |
4. System Board | |
107X | 1. Check SCSI terminators |
Check for proper installation | for proper installation |
of SCSI terminators. | 2. SCSI Cable |
3. SCSI Terminator | |
4. SCSI Device | |
5. SCSI Adapter | |
1701 | 1. Hard Disk Drive |
Hard disk drive failed. | |
Press F1 to restart the system. | |
1702 | 1. Hard Disk Drive Adapter |
Hard disk drive controller error | if installed |
2. System Board | |
1704 | 1. Hard Disk Drive Adapter |
Hard disk drive configuration error, | if installed |
controller failed | 2. System Board |
1715 | 1. Run Setup and enter the |
The Hard Disk Drive Configuration | correct hard disk drive |
information is not correct | information |
1726 | 1. Hard Disk Drive |
Hard disk drive read error | |
Press F1 to restart the system | |
182X | 1. SCSI Adapter |
190X | 1. SCSI Cable |
Ensure that each SCSI device is | 2. SCSI Terminator |
properly installed and powered-on. | 3. SCSI Device |
4. SCSI Adapter | |
1XXX | 1. SCSI Adapter |
(not listed above) | |
221X | 1. SCSI Cable |
Ensure that each SCSI device is | 2. SCSI Terminator |
properly installed and powered-on. | 3. SCSI Device |
4. SCSI Adapter | |
221X 224X | 1. SCSI Adapter |
2401 | 1. Correct the switch setting |
The monochrome/color switch is not | 2. Display Adapter |
set correctly. | |
3XXX | 1. Check SCSI terminators for |
Check for proper installation of | proper installation |
SCSI terminators. | 2. SCSI Cable |
3. SCSI Terminator | |
4. SCSI Device | |
5. SCSI Adapter | |
4XXX | 1. SCSI Cable |
Ensure that each SCSI device is | 2. SCSI Terminator |
properly installed and powered-on. | 3. SCSI Device |
4. SCSI Adapter | |
6XXX | 1. SCSI Device |
GP_COM | 1. System Board |
The serial port test detected | |
an error. | |
GP_FDU | 1. Diskette Drive |
The diskette drive test detected | 2. System Board |
an error. | 3. Diskette Drive Cable |
4. Diskette | |
GP_HDU | 1. Hard Disk Drive |
The hard disk drive test detected | 2. Hard Disk Drive Cable |
an error. | 3. Hard Disk Drive Adapter |
(if installed) | |
4. System Board | |
GP_KBD | 1. Keyboard |
The keyboard test detected | 2. System Board |
an error. | |
GP_MBD | 1. System Board |
The system board test detected | 2. Processor |
an error. | 3. Real-Time Clock Assembly |
GP_MEM | 1. Memory Module Kit |
The memory test detected | 2. System Board |
an error. | |
GP_PDV | 1. Mouse |
The mouse test failed. | 2. System Board |
GP_PRT | 1. Printer |
The printer test detected | 2. System Board |
an error. | |
GP_VID | 1. Video Adapter |
The video test detected | 2. System Board |
an error. | 3. Color Display |
GRPCDR | 1. CD-ROM |
The CD-ROM test detected | 2. System Board |
an error. |
Please see the LEGAL - Trademark notice.