Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes (QAPlus/PRO)


  Error Codes (QAPlus/PRO)

Error Code/Symptom    FRU/Action
  
0000 1. Be sure the adapter Device
SCSI Adapter not enabled.     and Bus Master fields are enabled
      in the PCI configuration program.
      Refer to the documentation that
      was shipped with the computer.
  
002X 1. SCSI Adapter
  
008X 1. Check SCSI terminators for
Check for proper installation     proper installation
of SCSI terminators. 2. SCSI Cable
  3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
0115 1. System Board
Protected mode cannot be enabled.
0164 1. Run Setup and ensure
POST detected a base memory or expansion     the memory size is correct
memory size mismatch 2. Run the Expanded
      Memory Diagnostic tests.
  
0601 1. Set Configuration
Diskette configuration error
0610 1. Diskette Drive
Cannot find diskette controller 2. Diskette Drive Cable
for drive A. 3. Diskette Drive Adapter if installed
  4. System Board
  
0612 1. Diskette Drive
Cannot find diskette controller 2. Diskette Drive Cable
for drive B. 3. Diskette Drive Adapter if installed
  4. System Board
  
0616 1. Diskette Drive Adapter
Diskette drive reset failed.
0632 1. Diskette Drive A
Diskette drive 0 seek failure
0642 1. Diskette Drive B
Diskette drive 1 seek failure
0653 1. Format diskette
Diskette not formatted or defective 2. Diskette
  
0655 1. Diskette Drive
Diskette drive controller failed. 2. Diskette Drive Cable
  3. Diskette Drive Adapter if installed.
  4. System Board
  
107X 1. Check SCSI terminators
Check for proper installation     for proper installation
of SCSI terminators. 2. SCSI Cable
  3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
1701 1. Hard Disk Drive
Hard disk drive failed.
Press F1 to restart the system.
1702 1. Hard Disk Drive Adapter
Hard disk drive controller error     if installed
  2. System Board
  
1704 1. Hard Disk Drive Adapter
Hard disk drive configuration error,     if installed
controller failed 2. System Board
  
1715 1. Run Setup and enter the
The Hard Disk Drive Configuration     correct hard disk drive
information is not correct     information
  
1726 1. Hard Disk Drive
Hard disk drive read error
Press F1 to restart the system
182X 1. SCSI Adapter
  
190X 1. SCSI Cable
Ensure that each SCSI device is 2. SCSI Terminator
properly installed and powered-on. 3. SCSI Device
  4. SCSI Adapter
  
1XXX 1. SCSI Adapter
(not listed above)
221X 1. SCSI Cable
Ensure that each SCSI device is 2. SCSI Terminator
properly installed and powered-on. 3. SCSI Device
  4. SCSI Adapter
  
221X 224X 1. SCSI Adapter
  
2401 1. Correct the switch setting
The monochrome/color switch is not 2. Display Adapter
set correctly.
3XXX 1. Check SCSI terminators for
Check for proper installation of     proper installation
SCSI terminators. 2. SCSI Cable
  3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
4XXX 1. SCSI Cable
Ensure that each SCSI device is 2. SCSI Terminator
properly installed and powered-on. 3. SCSI Device
  4. SCSI Adapter
  
6XXX 1. SCSI Device
  
GP_COM 1. System Board
The serial port test detected
an error.
GP_FDU 1. Diskette Drive
The diskette drive test detected 2. System Board
an error. 3. Diskette Drive Cable
  4. Diskette
  
GP_HDU 1. Hard Disk Drive
The hard disk drive test detected 2. Hard Disk Drive Cable
an error. 3. Hard Disk Drive Adapter
      (if installed)
  4. System Board
  
GP_KBD 1. Keyboard
The keyboard test detected 2. System Board
an error.
GP_MBD 1. System Board
The system board test detected 2. Processor
an error. 3. Real-Time Clock Assembly
  
GP_MEM 1. Memory Module Kit
The memory test detected 2. System Board
an error.
GP_PDV 1. Mouse
The mouse test failed. 2. System Board
  
GP_PRT 1. Printer
The printer test detected 2. System Board
an error.
GP_VID 1. Video Adapter
The video test detected 2. System Board
an error. 3. Color Display
  
GRPCDR 1. CD-ROM
The CD-ROM test detected 2. System Board
an error.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.