NOTE: If you are not able to correct the problem using the IML and IPL Errors section, go to Undetermined Problems
Symptom/Error: | FRU/Action. |
---|---|
I999001X I999002X | 1. Restore the System Partition. If you |
I999003X I999004X | need assistance, see |
(The actions for these errors are valid only | 'Restoring the System Partition' |
when running the system from the hard disk) | |
I9990053 I9990054 | 1. Restart the computer from the |
I9990056 I9990057 | Reference Diskette. If the same |
I9990059 I9990063 | error code appears, try new |
I9990067 I9990069 | System Diskettes. |
(These actions for these errors are valid only | |
when running the system from the System Diskettes) | |
I999006X | 1. Power-off the computer. Insert |
the Reference Diskette, toggle the | |
override jumper, then power-on the | |
computer. Then restore the System | |
Partition. If you need assistance, see | |
'Restoring the System Partition'. | |
I999007X I999009X | 1. Restore the System Partition. |
(The actions for these errors are valid only | If you need assistance, see |
when running the system from the System Diskettes) | 'Restoring the System Partition'. |
I99900X1 I99900X2 | 1. Restart the computer from the |
I99900X3 I99900X4 | Reference Diskette. If the same |
I99900X6 I99900X7 | error code appears, try new |
I99900X9 | System Diskettes. |
(These actions for these errors are valid only | |
when running the system from the System Diskettes) | |
I99900X5 | 1. Power-off the computer, toggle the |
(Reference Diskette recovery prevented) | power-on password override jumper |
then power-on the computer. | |
I9990301 | 1. Cable failure |
(Boot routine unable to read boot record. | 2. Wrong Termination |
This is probably a hardware failure) | 3. SCSI Adapter/Controller |
4. Hard Disk | |
I9990302 | 1. Install an operating system |
(No operating system found on the default | 2. Check for a valid selectable startup |
SCSI hard disk) | sequence. |
I9990303 | 1. Restore the System Partition. |
The IML code did not load from the | If you need assistance, see |
System Partition. | 'Restoring the System Partition' |
I9990304 | 1. No operating system installed. |
(No startable device found. This error | 2. Selectable startup sequence does |
This error is on ASCII consoles only) | not contain the default drive. |
I9990305 | 1. No operating system installed. |
(No startable device found) | 2. Selectable startup sequence does |
not contain the default drive. | |
I9990306 | 1. Restart the computer from a |
(Invalid startup. Trying to start from | startable diskette or hard disk drive. |
a CD-ROM drive) | |
I9990401 | 1. System Board or Processor Board |
(Unauthorized access. Type or erase the | NOTE: Whichever contains the system ROM |
power-on password before replacing FRUs) | |
I9990402 I9990403 | 1. System Board or Processor Board |
NOTE: Whichever contains the system ROM | |
I9990600 I9990607 | 1. Power-off the computer. Insert |
I9990609 | the Reference Diskette, toggle the |
override jumper, then power-on the | |
computer. Then restore the | |
System Partition. | |
If you need assistance see | |
'Restoring the System Partition' |
Please see the LEGAL - Trademark notice.