Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Checking Startup Sequence and Hard Disk Drive


  1.  Start the computer from the Reference Diskette and select Set Features from the  Main Menu.
  2.  Select Set Startup Sequence and see if the default  hard disk  (usually drive 6) is in the startup sequence. If you receive an error message, follow the  instructions on the screen, then return here.
  3.  If the default drive is in the startup sequence, exit from the screen and the Main Menu, then  go to step 5. If the default drive if not  in the startup sequence, follow the instructions  on the screen, then continue with step 4.
  4.  Remove the Reference Diskette, power-off the computer, then power-on the computer. If the 'F1'  (Insert Diskette) icon appears on the screen, this means no operating system was found. Go to step 5.  If the 'Not OK' icon appears on the screen, this means that the system cannot access the System Partition.  Try updating the system programs. If you need assistance, see 'Updating the System Programs'.
  5.  Either install an operating system on a device that is in the startup sequence, or change the startup  sequence to include a device that has an operating system, then power-on the computer, check for the  normal power-up sequence and then run the advanced diagnostics test. If the problem still exists, suspect the  SCSI controller, then the hard disk drive.

NOTE: If you are not able to correct the problem using the IML and IPL Errors section, go to Undetermined Problems

Symptom/Error:    FRU/Action.
  
I999001X I999002X 1. Restore the System Partition. If you
I999003X I999004X     need assistance, see
(The actions for these errors are valid only     'Restoring the System Partition'
when running the system from the hard disk)
I9990053 I9990054 1. Restart the computer from the
I9990056 I9990057     Reference Diskette. If the same
I9990059 I9990063     error code appears, try new
I9990067 I9990069     System Diskettes.
(These actions for these errors are valid only
when running the system from the System Diskettes)
I999006X 1. Power-off the computer. Insert
      the Reference Diskette, toggle the
      override jumper, then power-on the
      computer. Then restore the System
      Partition. If you need assistance, see
      'Restoring the System Partition'.
  
I999007X I999009X 1. Restore the System Partition.
(The actions for these errors are valid only     If you need assistance, see
when running the system from the System Diskettes)     'Restoring the System Partition'.
  
I99900X1 I99900X2 1. Restart the computer from the
I99900X3 I99900X4     Reference Diskette. If the same
I99900X6 I99900X7     error code appears, try new
I99900X9     System Diskettes.
(These actions for these errors are valid only
when running the system from the System Diskettes)
I99900X5 1. Power-off the computer, toggle the
(Reference Diskette recovery prevented)     power-on password override jumper
      then power-on the computer.
  
I9990301 1. Cable failure
(Boot routine unable to read boot record. 2. Wrong Termination
This is probably a hardware failure) 3. SCSI Adapter/Controller
  4. Hard Disk
  
I9990302 1. Install an operating system
(No operating system found on the default 2. Check for a valid selectable startup
SCSI hard disk)     sequence.
  
I9990303 1. Restore the System Partition.
The IML code did not load from the     If you need assistance, see
System Partition.     'Restoring the System Partition'
  
I9990304 1. No operating system installed.
(No startable device found. This error 2. Selectable startup sequence does
This error is on ASCII consoles only)     not contain the default drive.
  
I9990305 1. No operating system installed.
(No startable device found) 2. Selectable startup sequence does
      not contain the default drive.
  
I9990306 1. Restart the computer from a
(Invalid startup. Trying to start from     startable diskette or hard disk drive.
a CD-ROM drive)
I9990401 1. System Board or Processor Board
(Unauthorized access. Type or erase the    NOTE: Whichever contains the system ROM
power-on password before replacing FRUs)
I9990402 I9990403 1. System Board or Processor Board
     NOTE: Whichever contains the system ROM
  
I9990600 I9990607 1. Power-off the computer. Insert
I9990609     the Reference Diskette, toggle the
      override jumper, then power-on the
      computer. Then restore the
      System Partition.
      If you need assistance see
      'Restoring the System Partition'


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.