Symptom/Error: | FRU/Action. |
---|---|
000101XX | 1. Run Advanced Diagnostics |
(Interrupt failure. Possibly a | 2. 486DX33 Upgrade (70/80) |
bad battery or processor) | |
000102XX | 1. Run Advanced Diagnostics |
(ROM checksum or timer error. Possibly | 2. 486DX33 Upgrade (70/80) |
a bad battery or processor) | |
(If the battery was removed while replacing | |
the 80386 processor in a model 70, with a | |
486DX33 Processor Upgrade (FRU Number | |
92F0436), remove the 486DX33 processor | |
and install the 80386 processor, then | |
install the battery. Configure the system | |
and re-install the 486DX33 processor | |
without removing the battery.) | |
00010300 | 1. Processor Board (90/95) |
(Checksum or timer error. If it is a | 2. System Board |
20 MHz board, and the processor is not a | |
487SX, the jumper must be | |
in positions 2 and 3) | |
(487SX is indicated on the processor) | |
000102XX 000103XX | 1. System Board |
000104XX 000107XX | 2. Processor Board |
000105XX | (Information only) |
(Command not accepted) | |
000106XX | 1. Run Advanced Diagnostics |
(Converting logic test failure) | |
000107XX 000108XX | 1. System Board Memory |
000109XX | 2. System Board |
(Interrupt or memory failure) | 3. Processor Board (90/95) |
4. Any Adapter | |
5. Bus Adapter | |
00010XXX | 1. System Board |
000110XX | 1. Memory Module Kit |
(Check Memory) (For Model 95, also | 2. System Board |
see 000201XY for socket location list) | |
000111 | 1. Adapter Memory |
I/O channel check | 2. Expansion Adapter |
3. System Board | |
000112XX 000113XX | 1. System Board |
(Possible MC-timeout error) | 2. Processor Board (90/95) |
000114XX | 1. Any Adapter |
(ROM error) | 2. Bus Adapter |
000115XX | 1. System Board |
(80386 protected mode failure, or BIOS | 2. 486DX33 Upgrade (70/80) |
checksum error) | |
000116XX | 1. Run Advanced Diagnostics |
(Possible read/write problem) | 2. 486DX33 Upgrade (70/80) |
000118XX | 1. System Board Memory |
(Previously detected error. | 2. Processor Board (90/95) |
Run Advanced Diagnostics) | |
000119XX | 1. Run Automatic Configuration |
(2.88MB diskette drive is | |
installed but not supported.) | |
2. System Board | |
00011XXX | 1. System Board |
(not listed above) | |
000120XX | 1. System Board Processor Cache |
Possible Processor self test failure) | (90/95) |
2. Processor Board | |
(90/95) | |
000121XX | (Information only) |
(A problem was detected during | |
memory remapping (256KB ROM Error)) | |
000122XX | 1. Run Advanced Diagnostics |
(POST found a hardware error) | |
00012201 00012202 | 1. Run Advanced Diagnostics |
00012203 00012204 | |
00012205 00012206 | |
00012207 00012208 | |
(Data error, Possible system board | |
failure) | |
000129XX | 1. Run Advanced Diagnostics |
2. Cache Kit | |
3. System Board | |
000130XX | 1. Check Drive Sequence |
(POST could not start the operating | |
system. Operating system loaded ? Is | |
the boot drive in the selectable drive | |
sequence ? | |
00013001 | 1. Delete diskette drive from |
(Security system is being used, but the | the startup sequence if so |
computer is not totally secured because | desired. |
there is a diskette drive in the | |
startup sequence) | |
00013002 | 1. Run Automatic Configuration |
(Drive startup sequence is corrupt | then reset the selectable drive |
or invalid) | startup sequence. If the problem |
still exists, replace the | |
system board | |
00013003 | 1. Run Automatic Configuration |
(EEPROM could not be read) | If the problem still exits, replace |
the system board. | |
000131XX | 1. System Board |
000132XX | 1. Run Advanced Diagnostics |
(DMA extended registers error) | |
000133XX | 1. Run Advanced Diagnostics |
(DMA verify function error. Logic failed.) | |
000134XX | 1. Run Advanced Diagnostics |
(DMA arbitration logic error.) | |
00014905 | 1. System Board |
2. Processor Board | |
00014908 00014909 | 1. System Board |
Before replacing any FRUs, see | 2. Tamper Evident Switches |
'Cover Lock and Tamper-Evident Switches' | 3. Keylock Assembly |
000152XX | 1. Run Advanced Diagnostics |
(Real time clock error. (This is not | |
always a hardware failure. See also | |
'Real-Time Clock Problems' | |
000156XX | 1. Start the system from the |
(Security error. The covers were | Reference diskette (or server |
removed without using the key. The | image) and reconfigure the system. |
tamper evident switch was tripped.) | 2. Security Switch Assembly |
3. System Board | |
000160XX | 1. Run Advanced Diagnostics |
(System Board ID not recognized. | |
Possible system board failure) | |
000161XX | 1. Battery |
CAUTION: | 2. Processor Board (90/95) |
The lithium battery (IBM part number | 3. System Board |
33F8354) in your computer presents | 4. Bus Adapter |
a fire, explosion, or severe burn risk. | |
Use of another battery could result in | |
ignition or explosion of the battery. | |
000162XX | 1. Any Device |
(Be sure all devices are powered-on. | 2. Battery |
(Check Enable/Disable settings) | |
Configuration changed ? If so, run | |
Automatic Configuration. | |
000163XX | 1. Set Date and Time |
(Date and time error) | |
00016000 00016400 | 1. Set Configuration, Features |
00016500 00016700 | 2. System Board |
00016900 | |
(If setting configuration, date and time | |
does not solve the problem, see | |
Devices List' | |
000166XX | 1. Run Advanced Diagnostics |
(Adapter-busy. Reseat all adapters) | |
000167XX | 1. Set Features. Set date and time |
(Clock is not working correctly.) | |
000168XX | 1. Run Advanced Diagnostics |
(Real time clock error. this is not always | |
a hardware failure. also see | |
'Real-Time Clock Problems.) | |
000169XX | 1. Processor Board |
Processor configuration error. (Run Automatic | 2. System Board |
Configuration, then verify that the processor | |
configuration information is correct before | |
replacing FRUs) | |
000170XX | 1. From Set Configuration, select |
(ASCII console setup conflict error. | Change Configuration, and enable |
The serial port is disabled) | the port |
000171XX | 1. Battery |
2. Processor Board (90/95) | |
3. System Board | |
4. Bus Adapter | |
000172XX | 1. System Board |
000173XX | 1. Set Configuration/Features |
(Possibly a weak battery) | |
000174XX | 1. Any Device |
(If the configuration has been changed, | 2. System Board |
run Automatic Configuration. Otherwise | 3. Bus Adapter |
run Advanced Diagnostics) | |
(Check 'SCSI Device Default Settings' | |
000175XX | 1. System Board |
(Security error. The system board EEPROM | |
failed) | |
000176XX | 1. Start the system from the |
(Security error. The covers were removed | Reference Diskette (or server |
without using the key. The tamper evident | image) and reconfigure the |
switch was tripped) | system. |
2. Security Switch Assembly | |
3. System Board | |
000177XX 000178XX | 1. System Board |
Security error. Passwords corrupted) Reset. | |
000179XX | 1. Go into the log and note the |
(System error log might be full) | errors. Clear the log, then |
run Advanced Diagnostics. | |
000181XX | 1. Run Automatic Configuration |
(The computer requires a network adapter | 2. Network Adapter |
for remote IPL or a hard disk drive ID of | 3. Hard Disk Drive |
LUN 0, for IML, neither of these were | 4. System Board |
detected | |
000182XX | (Information only) |
(Privileged access password (PAP) data is | |
corrupted. To restore it, move jumper JMP2 to | |
position '0' write enabled). | |
000183XX | 1. Enter the Privileged access |
(Wrong password entered) | password (PAP) instead of |
the power-on password. | |
000184XX | 1. User must reset the password. |
(Power-on password corrupted) | |
000185XX | 1. Run Select Startup Sequence |
(Selectable startup sequence corrupted) | utility. Reset user's chosen |
startup sequence. | |
000186XX | 1. Run System Board |
(Security error, Hardware failed) | |
000187XX | 1. Select Set system identification |
(Vital Product Data (VPD) error. System | from the Reference Diskette, |
serial number information corrupted) | System Partition (or server |
image) and type the system serial | |
number. If problem remains, | |
suspect the system board. | |
000188XX | 1. Run Automatic Configuration |
(Vital Product Data (VPD) error) | |
000189XX | (Information only) |
(The wrong password was entered | |
3 times. Clear the system error log and | |
restart the system) | |
000191XX | 1. Run Advanced Diagnostics |
(82385 cache test failed) | |
000194XX | 1. System Board Memory |
2. Memory Riser Card (90) | |
3. Memory Module Kit | |
000199XX | 1. Run the Flash Update |
(User indicated configuration is invalid) | Utility (PS/2 9553-xBx Only) |
2. System Board | |
0001XXXX | 1. System Board |
(not listed above) | Processor Board (90/95) |
2. 486DX33 Upgrade (70/80) | |
3. Any Adapter | |
4. Bus Adapter | |
000201XX 000205XX | 1. System Board Memory |
(Reseat System Board Memory) | 2. System Board |
00020XXY 000217XY | 1. System Board Memory |
(if the 'Y' digits is in the range | Memory Riser Card (90) |
'G' to 'V', suspect the model 90/95 | Processor Board |
processor board first) | 2. System Board |
000210XX 000211XX | 1. Processor Board (90/95) |
(Check memory) | 2. System board Memory |
3. Memory Riser Card (90) | |
4. System Board | |
000214XX 000215XX | 1. System Board Memory |
000216XX 000221XX | Memory Riser Card (90) |
000226XX 000240XX | System board |
000235XX 000241XX | Processor Board (90/95) |
(Check memory. It might be the wrong | 2. Bus Adapter |
type or wrong speed) | |
000221XX | 1. System Board |
(ROM to RAM parity error) | |
000231XX | 1. Expanded Memory Option |
000235XX | 1. Processor/System Board. |
Single-Bit (correctable) ECC Memory error | |
00024300 00024400 | 1. Processor Board (90/95) |
00024500 00024600 | 1. Processor Board |
(Check memory) | 2. Memory Riser Card (90) |
3. System Board | |
4. System Board Memory | |
00024700 | 1. Processor Board (90/95) |
000251XX | (Information only) |
(Memory location changed on the memory | |
expansion option) | |
000252XX | 1. Processor Board (90/95) |
2. System Board | |
00025300 00025400 | 1. Processor Cache (90/95) |
2. Processor Board | |
000255XX | 1. System Board Memory |
(Check Memory) | 2. System Board |
00029000 | 1. Correct the unsupported |
(Unsupported memory combination | combination of ECC and parity |
detected) | memory modules. Run Automatic |
Configuration, then rerun | |
Advanced Diagnostics | |
000291XX 000292XX | 1. Run Automatic Configuration |
000293XX 000294XX | then rerun Advanced Diagnostics |
(Checksum value mismatch) | |
000295XX 000296XX | 1. System Board Memory |
(Check memory for an unsupported | |
configuration or modules) | |
00029800 | 1. System Board Memory |
(Checksum value mismatch) | Run Automatic Configuration |
then rerun Advanced Diagnostics | |
0002XX00 | 1. 486DX33 Upgrade (70/80) |
(not listed above) | |
000301XX 000302XX | 1. Keyboard Cable |
2. System Board | |
000303XX 000304XX | 1. System Board |
2. Keyboard | |
3. Keyboard Cable | |
000305XX | 1. Fuse |
(Keyboard voltage error. If no fuse in system | 2. Keyboard Cable |
replace system board) | |
000306XX | 1. Check for Unsupported Keyboard |
(Wrong Keyboard attached ?) | |
000307XX | 1. Keyboard |
2. Keyboard Cable | |
000320XX | 1. System Board |
000401XX to 000405XX | 1. System Board |
0005XXXX | 1. Display Adapter (any type) |
000601XX | 1. Defective Diskette |
2. Diskette Drive | |
2. System Board | |
000602XX | 1. Defective Diskette |
(Invalid boot record) | |
000604XX | 1. Diskette Drive |
(Unsupported drive or cable. | 2. System Board |
Drive must be media sense type) | 3. Diskette Drive Cable |
000605XX | 1. Run Advanced Diagnostics |
(Diskette drive error) | |
000606XX 000607XX | 1. Diskette |
000610XX 000621XX | 2. Diskette Drive |
000622XX 000623XX | 3. System Board |
000624XX 000630XX | |
000631XX 000632XX | |
000633XX 000640XX | |
000641XX 000642XX | |
000643XX 000650XX | |
000651XX 000652XX | |
000653XX 000654XX | |
000656XX 000657XX | |
000658XX 000659XX | |
000660XX | |
(Generally, these are media errors. | |
Try a known good diskette. if the | |
error appears again, replace the drive.) | |
000655XX | 1. System Board |
000662XX | (Information only) |
(Wrong drive type installed) | |
000663XX | (Information only) |
(Wrong media type in the drive) | |
000668XX | 1. Diskette Drive |
0006XXXX | 1. Diskette Drive |
(not listed above) | 2. System Board |
3. Diskette Drive Cable | |
0007XXXX | 1. Math Coprocessor |
For a 486 processor , erase COPROC.DGS | 2. 486DX33 Upgrade (70/80) |
from the backup Reference Diskette, then | 3. System Board |
restore the system partition from the | |
corrected backup Reference Diskette. | |
Re-run Advanced Diagnostics. | |
00265 | (Information only) |
(Ethernet Adapter terminator not connected) | (Thin/Thick or Twisted Terminator) |
00100203 | 1. System Board |
00110100 | 1. Run Advanced Diagnostics |
(Serial connector error, possible system | |
board failure) | |
001101XX 00110200 | 1. System Board |
00110600 00110800 | 2. Any Serial Device |
00110900 | |
001102XX | 1. Run Advanced Diagnostics |
(Card selected feedback error) | |
001103XX | 1. Run Advanced Diagnostics |
(Port fails register check) | 2. System Board |
001106XX | 1. Run Advanced Diagnostics |
(Serial option cannot be turned off) | 2. System Board |
001107XX | 1. Serial Device Cable |
2. System Board | |
001110XX | 1. Run Advanced Diagnostics |
(Register test failed) | 2. System Board |
001116XX | 1. Run Advanced Diagnostics |
(16550 interrupt error) | |
001117XX | 1. Run Advanced Diagnostics |
(Failed baud rate test) | |
0011XXXX | 1. System Board |
(not listed above) | |
(See 'Power Supply Voltage Check' | |
before replacing system board) | |
001201XX | 1. System Board |
(Check voltages) | 2. Any Serial Device |
001202XX 001206XX | 1. Dual Async Adapter/A |
001208XX 001209XX | 2. System Board |
0012XXXX | 3. Any Serial Device |
001207XX | 1. Communications Cable |
2. Dual Async Adapter/A | |
00129020 | 1. Cached Processor Option |
(Disk cache error) | 2. System Board |
001301XX 001302XX | 1. Game Adapter |
2. Joystick | |
001402XX | (Information only) |
(Printer not ready) | |
001403XX | (Information only) |
(No paper error, or interrupt failure) | |
001404XX | 1. Run Advanced Diagnostics |
(System board timeout failure) | |
001405XX | 1. Run Advanced Diagnostics |
(Parallel adapter error) | |
001406XX | 1. Run Advanced Diagnostics |
(Presence test error) | |
0014XXXX | 1. Printer |
(not listed above) | 2. System Board |
(Check printer before replacing | |
system board | |
001701XX 001703XX | 1. Hard Disk Drive |
001704XX 001714XX | 2. Cable (ST506) |
0017XXXX | 3. Hard Disk Adapter (ST506) |
(Not listed below) | 4. System Board |
5. Power Supply | |
001702XX | 1. Hard Disk Adapter |
001705XX 001706XX | 1. Format the Drive |
001707XX 001708XX | 2. Hard Disk Drive |
001710XX 001711XX | |
001712XX 001713XX | |
001715XX 001716XX | |
001717XX 001726XX | |
001735XX 001750XX | |
001751XX 001752XX | |
001753XX 001754XX | |
001755XX 001757XX | |
001780XX 001781XX | |
001782XX 001790XX | |
001791XX | |
(Read/write problem. Be sure the | |
drive type is supported. If it is, try | |
a low level format. If the error continues, | |
replace the hard disk drive) | |
00180100 to 00180700 | 1. System Board |
00186XXX | 1. Set Configuration/Features |
2. Battery | |
0018XXXX | 1. System Board |
(not listed above) | Expansion Unit |
00240100 00240200 | 1. Display (any type) |
(If screen colors change) | |
00240100 00240200 | 1. System Board |
(If screen colors are OK) | 2. Display (any type) |
00240900 | 1. Display (any type) |
00241000 | 1. System Board |
003015XX | 1. Baseband Adapter |
(Check for missing wrap or terminator | 2. Baseband Cable |
plug on the adapter) | |
0037XXXX | 1. System Board |
(This is usually caused by the | 2. Hard Disk |
SCSI controller built into the | 3. Hard Disk Cable |
system board. | |
004611XX 004630XX | 1. Multiport/2 Interface Board |
2. Multiport/2 Adapter | |
004612XX 004613XX | 1. Memory Module Package |
004640XX 004641XX | 2. Multiport/2 Adapter |
00465000 004613XX | 1. Multiport Interface Cable |
0046XXXX | 1. Multiport/2 Adapter |
(not listed above) | 2. Multiport/2 Interface Board |
3. Memory module Package | |
005600XX | 1. Financial System |
2. Controller Adapter | |
0062XXXX | 1. 1st Store Loop Adapter |
2. Adapter Cable | |
0063XXXX | 1. 2nd Store Loop Adapter |
2. Adapter Cable | |
0064XXXX | 1. Network Adapter |
(See 'Network Service Procedures') | |
0071XXXX | 1. Voice Adapter |
0074XXXX | 1. 8514/A Display Adapter |
(Adapter jumper in the correct position ? | 8514/A Memory Module |
See 'Display Adapter 8514/A') | 2. System Board |
007509XX | 1. Display Adapter (any type) |
(Check display) | 2. Display (any type) |
3. System Board | |
4. Video Memory | |
007510XX | 1. XGA Adapter |
(Check display) | 2. Video Memory |
0076XXXX | 1. Page Printer Adapter |
0078XXXX | 1. High Speed Adapter |
0079XXXX | 1. 3117 Adapter |
00800100 to 008012XX | 1. Pointing Device (Mouse) |
(System Board Upgrade Model 50, 55 Only) | 2. System Board |
00850X00 00851XXX | 1. 80286 Memory Option Adapter/A |
2. System Board | |
00852X00 00851XXX | 1. Memory Module Package on |
the 80286 Memory Adapter/A | |
2. Adapter Memory | |
3. System Board | |
00860100 008602XX | 1. Pointing Device (Mouse) |
2. System Board | |
008603XX 008604XX | 1. System Board |
2. Pointing Device (Mouse) | |
0089XXXX | 1. Music Adapter |
0091XXXX | 1. Optical Drive |
2. Adapter | |
0096XXXX | 1. SCSI Adapter |
(This adapter has cache) | 2. Any SCSI Device |
3. System Board | |
010001XX | (Information only) |
(Multiprotocol Adapter/A not found) | |
010002XX | 1. Run Advanced Diagnostics |
(Card selected feedback error) | |
010007XX | 1. Communications Cable |
2. Multiprotocol Adapter/A | |
010008XX 010009XX | 1. Multiprotocol Adapter/A |
2. Any Serial Device | |
0100XXXX | 1. Multiprotocol Adapter/A |
(not listed above) | 2. System Board |
3. Bus Adapter | |
0101102X 0101106X | 1. Modem Adapter/A |
0101108X 0101109X | 2. Data/Fax Modem |
3. Any Serial Device | |
010101XX 010102XX | 1. Have the customer verify |
010104XX 010105XX | that the correct operating |
010106XX 010107XX | system device drivers are |
010108XX 010109XX | installed and operational |
010111XX 010112XX | 2. Modem |
010103XX 010114XX | |
010105XX 010116XX | |
010103XX 010110XX | 1. System Board |
0101171X | 2. Data/Fax Modem |
010117XX | 1. Check system speaker |
(not listed above) | 2. Check PSTN cable |
3. External DAA if installed | |
4. Modem | |
010118XX | 1. Run System Diagnostics and |
verify the correct operation of | |
the modem slot | |
2. Modem | |
010119XX | 1. Diagnostics detected a |
Non-IBM modem | |
2. Modem | |
010120XX | 1. Check PSTN Cable |
2. External DAA (if installed) | |
3. Modem | |
010132XX 010133XX | 1. Modem |
010134XX 010135XX | |
010136XX 010137XX | |
010138XX 010139XX | |
010140XX 010141XX | |
010142XX 010143XX | |
010144XX 010145XX | |
010146XX 010147XX | |
010148XX 010149XX | |
010150XX 010151XX | |
010152XX | |
010153XX | 1. Data/Fax Modem |
2. System Board | |
0101XXXX | 1. Modem Adapter/A |
(not listed above) | 2. Data/Fax Modem |
3. System Board | |
010450XX 010451XX | 1. Run Advanced Diagnostics |
010490XX 010491XX | 2. Riser Card (if installed) |
010492XX 010499XX | 3. Hard Disk Drive |
(Read/write error) | 4. System Board |
010452XX | 1. Run Advanced Diagnostics |
(Seek test error) | |
010453XX | (Information only) |
(Wrong drive type ?) | |
010454XX | 1. Run Advanced Diagnostics |
(Sector buffer test error) | |
010455XX 010456XX | 1. Run Advanced Diagnostics |
(Controller error) | |
010459XX | (Information only) |
(Drive diagnostic command error) | |
010461XX | 1. Run Advanced Diagnostics |
(Drive format error) | |
010462XX | 1. Run Advanced Diagnostics |
(Controller seek error) | |
010464XX | 1. Run Advanced Diagnostics |
(Hard Disk read error) | |
010467XX | 1. Run Advanced Diagnostics |
(Drive non fatal seek error) | |
010468XX | 1. Run Advanced Diagnostics |
(Drive fatal seek error) | |
010469XX | 1. Run Advanced Diagnostics |
(Drive soft error count exceeded) | |
010470XX 010471XX | 1. Run Advanced Diagnostics |
010472XX | |
(Controller wrap error) | |
010473XX | (Information only) |
(Corrupt data. Low level might be required | |
010480XX | 1. Hard Disk Drive (ESDI) |
2. Drive Cable | |
3. Controller | |
4. System Board | |
010481XX | 1. Run Advanced Diagnostics |
(ESDI drive D seek error) | |
010482XX | 1. Run Advanced Diagnostics |
(Drive select acknowledgement bad) | |
010490XX 010491XX | 1. Run Advanced Diagnostics |
(Drive 0,1 read error) | 2. Riser Card (If installed) |
3. Hard Disk Drive | |
4. System Board | |
010499XX | 1. Run Advanced Diagnostics |
(Drive controller error) | 2. Riser Card (If installed) |
3. Hard Disk Drive | |
4. System Board | |
010483XX | 1. Hard Disk Adapter (ESDI) |
2. System Board | |
0104XXXX | 1. Hard Disk Drive |
(not listed above) | 2. Hard Disk Adapter (ESDI) |
3. Hard Disk Cable | |
4. Power Supply | |
0106XXXX | 1. Ethernet Network Adapter/A |
(See 'Network Service Procedures') | 2. System Board |
3. Bus Adapter | |
0107XXXX | 1. 5.25-Inch External Diskette Drive |
2. 5.25-Inch Diskette Drive Adapter/A | |
0109XXXX | 1. ActionMedia Adapter/A |
(Check the adapter cables) | 2. System Board |
0112XXXX | 1. SCSI Adapter |
(This adapter does not have cache) | 2. Any SCSI Device |
3. System Board | |
0119XXXX | 1. 3119 Adapter |
0121XXXX | 1. 300/1200/2400 Modem/A |
2. Any serial Device | |
3. System Board | |
01290001 01290002 | 1. Run Advanced Diagnostics |
01290003 01290002 | |
01290007 01290002 | |
(Possibly a recoverable processor board error) | |
01290050 01290051 | 1. Processor Board |
01290052 01290053 | 2. System Board |
01290054 01290055 | |
01290056 | |
(Probably a fatal error) | |
01290100 012902XX | 1. Processor Board |
01290400 01290700 | 2. System Board Cache |
01290800 | 3. System Board |
(Cache error) | |
012903XX | 1. Math Coprocessor |
(Math Coprocessor error) | 2. Processor Board |
01290XXX | 1. Processor Cache |
(not listed above) | 2. Processor Board |
3. System Board | |
01291200 01291300 | 1. Run Advanced Diagnostics |
01291400 012915XX | |
012916XX 01291800 | |
01291900 01294040 | |
01294041 | |
(Possible processor Board error) | |
01291700 | 1. Processor Board (90/95) |
(If it is a 20 MHz board, and the | |
processor is a 487SX, the jumper must be | |
in positions 1 and 2) (487SX is indicated | |
on the processor) | |
01293000 | 1. Jumpered Incorrectly |
(90/95 Processor board EEPROM jumper is | 2. Processor Board |
in the wrong position) | |
01294042 | 1. Processor Board |
(POST / BIOS EEPROM error. Update | |
diskette is required) | |
01294400 | 1. Restart the system, then |
(A hardware default interrupt occurred) | run Advanced Diagnostics |
01295050 01295056 | 1. Restart the system, then |
01295060 01295061 | run Advanced Diagnostics |
01295070 01295071 | |
01295072 01295073 | |
01295074 01295075 | |
01295076 01295077 | |
01295078 01295079 | |
01295080 01295081 | |
01295082 01295083 | |
01295085 01295086 | |
01295087 01295088 | |
01295090 01295091 | |
01295094 01295095 | |
01295096 01295097 | |
(Processor board errors) | |
0129X300 | 1. Busmaster Adapter (90/95) |
(Busmaster arbitration error. If more | 2. Processor Board |
than one is installed, remove them | |
one at a time to isolate the failure) | |
01299000 | 1. Run Automatic Configuration |
(VPD error, processor board replaced ? | |
Processor board serial number detected | |
does not match serial number stored) | |
0136XXXX | 1. ISDN Primary Rate Adapter |
2. System Board | |
0137XXXX | 1. System Board |
0141XXXX | 1. Realtime Interface Coprocessor |
Portmaster Adapter | |
0143XXXX | 1. Japanese Display Adapter |
2. System Board | |
01471000 014711XX | 1. System Board Display Adapter (any type) |
2. Adapter Video Memory | |
0148XX00 | 1. Display Adapter (any type) |
014901XX 014902XX | 1. Display Adapter (any type) |
01491XXX 014922XX | 2. System Board |
3. Display (any type) | |
014932XX | 1. External Display (any type) |
2. Display Adapter (any type) | |
0152XXXX | 1. XGA Display Adapter/A |
2. System Board | |
015302XX | 1. S/370 Channel Emulator/A Adapter |
015304XX | 1. S/370 Channel Emulator/A Adapter |
2. S/370 Emulator/A Channel Cable | |
0161XXXX | 1. FaxConcentrator Adapter/A |
0164XXXX | 1. 120MB Internal Tape Drive |
2. Diskette Cable | |
3. System Board | |
016500XX | 1. 6157 Tape Attachment Adapter |
016520XX 016540XX | 1. 6157 Streaming Tape Drive |
2. 6157 Tape Attachment Adapter | |
0166XXXX 0167XXXX | 1. Token-Ring Network Adapter/A |
(See 'Network Service Procedures') | 2. System Board |
3. Bus Adapter | |
018001XX | 1. Wizard Adapter |
(18001 to 18029) | 2. Wizard Adapter Memory |
018031XX | 1. Wizard Adapter Cable |
(18031 to 18039) | |
018441XX | (Information only) |
Unsupported memory module on 80386 adapter) | |
018451XX | (Information only) |
(Need to reconfigure. Module changed | |
on 80386 adapter) | |
0184XXXX | 1. Enhanced 80386 Memory Adapter/A |
0185XXXX | 1. DBCS Japanese Display Adapter/A |
2 System Board | |
0194XXXX | 1. Memory Module Package on the |
2-8MB80286 Memory Adapter | |
2. Memory adapter | |
3. System Board | |
020001XX to 020003XX | 1. Image Adapter/A |
Image-I Adapter/A | |
2. Memory Module DRAM or VRAM | |
020004XX | 1. Memory Module DRAM or VRAM |
2. Image Adapter/A Image-I Adapter/A | |
020005XX to 020010XX | 1. Image Adapter/A |
Image-I Adapter/A | |
2. Memory Module DRAM or VRAM | |
0200XXXX | 1. Image Adapter/A |
(not listed above) | Image-I Adapter/A |
2. Memory Module DRAM or VRAM | |
3. System Board | |
020101XX to 020103XX | 1. Printer/Scanner Option |
2. Image Adapter/A | |
3. Memory Module DRAM or VRAM | |
020104XX | 1. Memory Module DRAM or VRAM |
2. Printer/Scanner Option | |
3. Image Adapter/A | |
020105XX to 020110XX | 1. Printer/Scanner Option |
2. Image Adapter/A | |
3. Memory Module DRAM or VRAM | |
Image Adapter/A Memory Test failure | 1. Replace memory module |
indicated by graphic representation | (shown in graphic) |
of adapter | |
0206XXXX | 1. SCSI-2 Adapter |
2. Any SCSI Device | |
3. System Board | |
0208XXXX | 1. Any SCSI Device |
(Verify that there are no duplicate | |
SCSI ID settings on the same bus) | |
for Error Code Format see > | SCSI/Non-SCSI Error Code Format Codes |
for 0210XXXX 9xxx Error's see > | SCSI Fixed Disk Diagn. Return Codes |
0210XXXA (60MB) | 1. SCSI Hard Disk Drive |
0210XXXB (80MB) | 2. SCSI Adapter or the SCSI controller |
0210XXXC (120MB) | built into the system board. |
0210XXXD (160MB) | 3. SCSI Cable |
0210XXXE (320MB) | 4. SCSI ID Switch (On some models) |
0210XXXF (400MB) | |
0210XXXG (40MB) | |
0210XXXH (1GB) | |
0210XXXI (104MB) | |
0210XXXJ (212MB) | |
0210XXXM (2GB 8 bit 68-pin) | |
0210XXXN (540MB) | |
0210XXXO (1GB) | |
0210XXXQ (540MB) | |
0210XXXP (2GB 8 bit 50-pin) | |
0210XXXU (Size unknown) | |
(If it is an external device, check the | |
external voltages. | |
See 'SCSI Diagnostic Tests' and | |
'SCSI ID (Using to Help Isolate Failures' | |
before replacing any FRUs) | |
0210XXXX | 1. SCSI Hard Disk Drive |
(Internal bus, size unknown) | 2. SCSI Adapter or the SCSI controller |
built into the system board | |
0210XXX1 | 3. SCSI Cable |
(External bus, size unknown) | 4. SCSI ID Switch (on some models) |
The amber LED remains on. | 1. Tape Drive |
2. SCSI Cable (internal) | |
3. SCSI Adapter or the SCSI controller | |
built into the system board. | |
The green 'in use' LED fails to come on. | 1. Tape Drive |
2. SCSI Adapter or the SCSI controller | |
built into the system board. | |
3. SCSI Cable (internal) | |
SCSI Cable (external) | |
The tape is automatically ejected from | 1. Tape Cassette |
the drive. | 2. Drive |
SCSI ID on the rotary switch does not | 1. Rotary Switch Circuit Board |
match the SCSI ID set in configuration. | 2. Circuit Board Cable |
(Verify the drive switches inside the cover | 3. Tape Drive |
are set to zero) | |
Tape sticks/breaks in the drive. | 1. Tape Cassette |
(Verify that the tapes used meet | |
ANSI standard X3B5) | |
0212XXXX | 1. SCSI Printer |
2. Printer Cable | |
0213XXXX | 1. SCSI Processor |
0214XXXX | 1. WORM Drive |
0215XXXC | 1. CD-ROM Drive I |
0215XXXD | CD-ROM Drive II |
0215XXXE | Enhanced CD-ROM Drive II |
0215XXXU | Any CD-ROM Drive |
If it is an external device, and the | 2. SCSI Cable |
power-on LED is off, check external voltages) | 3. SCSI Adapter or the SCSI controller |
built into the system board. | |
0216XXXX | 1. Scanner |
0217XXXX | 1. Rewriteable Optical Drive |
(If it is an external device, and the | 2. SCSI Adapter or the SCSI controller |
power-on LED is off, check external voltages) | built into the system board. |
3. SCSI Cable | |
0218XXXX | 1. Changer |
(Check for multi CD tray, or juke box) | |
0219XXXX | 1. SCSI Communications Device |
024201Y0 024210Y0 | 1. ISDN/2 Adapter |
(Be sure the wrap plug is not missing) | 2. ISDN/2 Wrap Plug |
3. ISDN/2 Communications Cable | |
0243XXXX | 1. XGA-2 Display Adapter |
002460XX | 1. 90 MHz Processor Upgrade |
(without VRAM) | |
2. System Board | |
002461XX | 1. 90 MHz Processor Upgrade |
(with 1MB VRAM) | |
0258XXXX | 1. XGA-2 Display Adapter |
Video might have failed. | 2. System Board |
(Ensure that you are using diagnostic files | |
XGAANI.DGS and XGAPNI.DGS dated 03/06/93 | |
or later before you replace any FRUs. | |
Earlier files cause erroneous errors.) | |
0259XXXX | 1. SVGA Adapter |
2. System Board | |
0260XXXX | 1. System Board |
2. Any SCSI Device | |
0270XXXX | 1. RAID Adapter Controller |
2. System Board | |
0271XXXX | 1. RAID Hard Disk Drive |
2. System Board | |
0273XXXX | 1. 1 Mbps MicroChannel Infrared |
2. LAN Adapter | |
027485Y0 | 1. LANStreamer MC 16 Adapter |
Configuration Compare failure | |
027490Y0 | 1. LANStreamer MC 16 Adapter |
Adapter Card Test failure | |
027491Y0 | 1. LANStreamer MC 16 Adapter |
Open Phase Test failure | |
027492Y0 | 1. LANStreamer MC 16 Adapter |
Computer Problem | |
027493Y0 | 1. LANStreamer MC 16 Adapter |
Transmit/Receive Test failure | |
Check Adapter Cable/Wrap Plug | |
027499Y0 | 1. LANStreamer MC 16 Adapter |
General error | |
0274XXY0 | 1. LANStreamer MC 16 Adapter |
Y is SLOT # where Adapter installed | |
2. System Board | |
027501XX 027503XX | 1. ServerGuard Adapter |
027506XX 027507XX | 2. System Board |
027502XX 027504XX | 1. ServerGuard Adapter |
027510XX 027511XX | |
027533XX 027534XX | |
027536XX 027537XX | |
027509XX | 1. Remove redundant ServerGuard |
Adapters, run Auto Configuration | |
program, then retest | |
027512XX | 1. WMSELF.DGS diagnostics file missing |
2. WMSELF.DGS diagnostic file incorrect | |
027535XX | 1. 3V Lithium Backup Battery |
2. ServerGuard Adapter | |
027554XX | 1. Internal Temperature out of range |
2. ServerGuard Adapter | |
027555XX 027556XX | 1. ServerGuard Adapter |
2. System Power Supply | |
027557XX | 1. 7.2V NiCad Main Battery Pack |
2. ServerGuard Adapter | |
027558XX 027559XX | 1. PCMCIA Type II Modem |
027560XX 027561XX | 2. ServerGuard Adapter |
027562XX | 1. External Power Control Box |
not connected | |
2. External Power Control Box | |
3. ServerGuard Adapter | |
027563XX 027564XX | 1. External Power Control Box |
2. ServerGuard Adapter | |
0275XXXX | 1. Update Diagnostic Software |
027801X0 027859X0 | 1. Personal Voice Dictation Adapter/A |
027861X0 027863X0 | 1. OS/2 Device Driver for Voice Dictation Adapter/A is missing |
027864X0 | 1. Only one Voice Dictation PCMCIA Adapter is supported in a computer |
027865X0 | 1. The PCMCIA enabler is unable to read the card information |
027866X0 | 1. PCMCIA Card Socket Services not installed |
027871X0 | 1. The VoiceType Dictation PCMCIA Card was not found |
027880X0 027889x0 | 1. Check all Cables |
(Speaker test failed) | 2. Check external Speaker oper. control. |
027890X0 027899x0 | 1. Check all Cables |
(Microphone test failed) | 2. Check Microphone operating control. |
0279XXXX | 1. Fast/Wide Streaming - |
- RAID Adapter/A (FRU 06H3059) | |
Pass through Card & Cable | |
2. System Board | |
3. Signal Pass Through Card (if installed) | |
0281XXY0 | 1. Dual LANStreamer MC32 Adapter |
Y = slot number | XX = 85 Configuration Compare failure |
XX = type of error | XX = 90 Adapter Test Card failure |
XX = 91 Open Phase Test failure | |
XX = 92 Computer Problem | |
XX = 93 Transmit/Receive Test failure | |
XX = 99 General error | |
I998009X | 1. Restore System Partition |
I999XXXX | 1. Default Hard Disk Drive |
(This is usually not a hardware failure. | 2. Processor Board (90/95) |
Go to IML and IPL Errors before replacing | 3. SCSI Adapter |
FRUs. Specific I999XXXX error codes | 4. SCSI Cable |
are listed after IML and IPL Errors | |
for SCSI 0210xxxx 9xxx (Fixed Disk DIAGNOSE) Errorcodes see > SCSI Return Error-Codes |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.