Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric ERROR CODES / Micro Channel


  ERROR - Codes valid for all PS/2 (MC) Models

Symptom/Error:    FRU/Action.
  
000101XX 1. Run Advanced Diagnostics
(Interrupt failure. Possibly a 2. 486DX33 Upgrade (70/80)
bad battery or processor)
000102XX 1. Run Advanced Diagnostics
(ROM checksum or timer error. Possibly 2. 486DX33 Upgrade (70/80)
a bad battery or processor)
(If the battery was removed while replacing
the 80386 processor in a model 70, with a
486DX33 Processor Upgrade (FRU Number
92F0436), remove the 486DX33 processor
and install the 80386 processor, then
install the battery. Configure the system
and re-install the 486DX33 processor
without removing the battery.)
00010300 1. Processor Board (90/95)
(Checksum or timer error. If it is a 2. System Board
20 MHz board, and the processor is not a
487SX, the jumper must be
in positions 2 and 3)
(487SX is indicated on the processor)
000102XX 000103XX 1. System Board
000104XX 000107XX 2. Processor Board
  
000105XX     (Information only)
(Command not accepted)
000106XX 1. Run Advanced Diagnostics
(Converting logic test failure)
000107XX 000108XX 1. System Board Memory
000109XX 2. System Board
(Interrupt or memory failure) 3. Processor Board (90/95)
  4. Any Adapter
  5. Bus Adapter
  
00010XXX 1. System Board
  
000110XX 1. Memory Module Kit
(Check Memory) (For Model 95, also 2. System Board
see 000201XY for socket location list)
000111 1. Adapter Memory
I/O channel check 2. Expansion Adapter
  3. System Board
  
000112XX 000113XX 1. System Board
(Possible MC-timeout error) 2. Processor Board (90/95)
  
000114XX 1. Any Adapter
(ROM error) 2. Bus Adapter
  
000115XX 1. System Board
(80386 protected mode failure, or BIOS 2. 486DX33 Upgrade (70/80)
checksum error)
000116XX 1. Run Advanced Diagnostics
(Possible read/write problem) 2. 486DX33 Upgrade (70/80)
  
000118XX 1. System Board Memory
(Previously detected error. 2. Processor Board (90/95)
Run Advanced Diagnostics)
000119XX 1. Run Automatic Configuration
      (2.88MB diskette drive is
      installed but not supported.)
  2. System Board
  
00011XXX 1. System Board
(not listed above)
000120XX 1. System Board Processor Cache
Possible Processor self test failure)     (90/95)
  2. Processor Board
      (90/95)
  
000121XX     (Information only)
(A problem was detected during
memory remapping (256KB ROM Error))
000122XX 1. Run Advanced Diagnostics
(POST found a hardware error)
00012201 00012202 1. Run Advanced Diagnostics
00012203 00012204
00012205 00012206
00012207 00012208
(Data error, Possible system board
failure)
000129XX 1. Run Advanced Diagnostics
  2. Cache Kit
  3. System Board
  
000130XX 1. Check Drive Sequence
(POST could not start the operating
system. Operating system loaded ? Is
the boot drive in the selectable drive
sequence ?
00013001 1. Delete diskette drive from
(Security system is being used, but the     the startup sequence if so
computer is not totally secured because     desired.
there is a diskette drive in the
startup sequence)
00013002 1. Run Automatic Configuration
(Drive startup sequence is corrupt     then reset the selectable drive
or invalid)     startup sequence. If the problem
      still exists, replace the
      system board
  
00013003 1. Run Automatic Configuration
(EEPROM could not be read)     If the problem still exits, replace
      the system board.
  
000131XX 1. System Board
  
000132XX 1. Run Advanced Diagnostics
(DMA extended registers error)
000133XX 1. Run Advanced Diagnostics
(DMA verify function error. Logic failed.)
000134XX 1. Run Advanced Diagnostics
(DMA arbitration logic error.)
00014905 1. System Board
  2. Processor Board
  
00014908 00014909 1. System Board
Before replacing any FRUs, see 2. Tamper Evident Switches
'Cover Lock and Tamper-Evident Switches' 3. Keylock Assembly
  
000152XX 1. Run Advanced Diagnostics
(Real time clock error. (This is not
always a hardware failure. See also
'Real-Time Clock Problems'
000156XX 1. Start the system from the
(Security error. The covers were     Reference diskette (or server
removed without using the key. The     image) and reconfigure the system.
tamper evident switch was tripped.) 2. Security Switch Assembly
  3. System Board
  
000160XX 1. Run Advanced Diagnostics
(System Board ID not recognized.
Possible system board failure)
000161XX 1. Battery
CAUTION: 2. Processor Board (90/95)
The lithium battery (IBM part number 3. System Board
33F8354) in your computer presents 4. Bus Adapter
a fire, explosion, or severe burn risk.
Use of another battery could result in
ignition or explosion of the battery.
000162XX 1. Any Device
(Be sure all devices are powered-on. 2. Battery
(Check Enable/Disable settings)
Configuration changed ? If so, run
Automatic Configuration.
000163XX 1. Set Date and Time
(Date and time error)
00016000 00016400 1. Set Configuration, Features
00016500 00016700 2. System Board
00016900
(If setting configuration, date and time
does not solve the problem, see
Devices List'
000166XX 1. Run Advanced Diagnostics
(Adapter-busy. Reseat all adapters)
000167XX 1. Set Features. Set date and time
(Clock is not working correctly.)
000168XX 1. Run Advanced Diagnostics
(Real time clock error. this is not always
a hardware failure. also see
'Real-Time Clock Problems.)
000169XX 1. Processor Board
Processor configuration error. (Run Automatic 2. System Board
Configuration, then verify that the processor
configuration information is correct before
replacing FRUs)
000170XX 1. From Set Configuration, select
(ASCII console setup conflict error.     Change Configuration, and enable
The serial port is disabled)     the port
  
000171XX 1. Battery
  2. Processor Board (90/95)
  3. System Board
  4. Bus Adapter
  
000172XX 1. System Board
  
000173XX 1. Set Configuration/Features
(Possibly a weak battery)
000174XX 1. Any Device
(If the configuration has been changed, 2. System Board
run Automatic Configuration. Otherwise 3. Bus Adapter
run Advanced Diagnostics)
(Check 'SCSI Device Default Settings'
000175XX 1. System Board
(Security error. The system board EEPROM
failed)
000176XX 1. Start the system from the
(Security error. The covers were removed     Reference Diskette (or server
without using the key. The tamper evident     image) and reconfigure the
switch was tripped)     system.
  2. Security Switch Assembly
  3. System Board
  
000177XX 000178XX 1. System Board
Security error. Passwords corrupted) Reset.
000179XX 1. Go into the log and note the
(System error log might be full)     errors. Clear the log, then
      run Advanced Diagnostics.
  
000181XX 1. Run Automatic Configuration
(The computer requires a network adapter 2. Network Adapter
for remote IPL or a hard disk drive ID of 3. Hard Disk Drive
LUN 0, for IML, neither of these were 4. System Board
detected
000182XX     (Information only)
(Privileged access password (PAP) data is
corrupted. To restore it, move jumper JMP2 to
position '0' write enabled).
000183XX 1. Enter the Privileged access
(Wrong password entered)     password (PAP) instead of
      the power-on password.
  
000184XX 1. User must reset the password.
(Power-on password corrupted)
000185XX 1. Run Select Startup Sequence
(Selectable startup sequence corrupted)     utility. Reset user's chosen
      startup sequence.
  
000186XX 1. Run System Board
(Security error, Hardware failed)
000187XX 1. Select Set system identification
(Vital Product Data (VPD) error. System     from the Reference Diskette,
serial number information corrupted)     System Partition (or server
      image) and type the system serial
      number. If problem remains,
      suspect the system board.
  
000188XX 1. Run Automatic Configuration
(Vital Product Data (VPD) error)
000189XX     (Information only)
(The wrong password was entered
3 times. Clear the system error log and
restart the system)
000191XX 1. Run Advanced Diagnostics
(82385 cache test failed)
000194XX 1. System Board Memory
  2. Memory Riser Card (90)
  3. Memory Module Kit
  
000199XX 1. Run the Flash Update
(User indicated configuration is invalid)     Utility (PS/2 9553-xBx Only)
  2. System Board
  
0001XXXX 1. System Board
(not listed above)     Processor Board (90/95)
  2. 486DX33 Upgrade (70/80)
  3. Any Adapter
  4. Bus Adapter
  
000201XX 000205XX 1. System Board Memory
(Reseat System Board Memory) 2. System Board
  
00020XXY 000217XY 1. System Board Memory
(if the 'Y' digits is in the range     Memory Riser Card (90)
'G' to 'V', suspect the model 90/95     Processor Board
processor board first) 2. System Board
  
000210XX 000211XX 1. Processor Board (90/95)
(Check memory) 2. System board Memory
  3. Memory Riser Card (90)
  4. System Board
  
000214XX 000215XX 1. System Board Memory
000216XX 000221XX     Memory Riser Card (90)
000226XX 000240XX     System board
000235XX 000241XX     Processor Board (90/95)
(Check memory. It might be the wrong 2. Bus Adapter
type or wrong speed)
000221XX 1. System Board
(ROM to RAM parity error)
000231XX 1. Expanded Memory Option
  
000235XX 1. Processor/System Board.
Single-Bit (correctable) ECC Memory error
00024300 00024400 1. Processor Board (90/95)
  
00024500 00024600 1. Processor Board
(Check memory) 2. Memory Riser Card (90)
  3. System Board
  4. System Board Memory
  
00024700 1. Processor Board (90/95)
  
000251XX     (Information only)
(Memory location changed on the memory
expansion option)
000252XX 1. Processor Board (90/95)
  2. System Board
  
00025300 00025400 1. Processor Cache (90/95)
  2. Processor Board
  
000255XX 1. System Board Memory
(Check Memory) 2. System Board
  
00029000 1. Correct the unsupported
(Unsupported memory combination     combination of ECC and parity
detected)     memory modules. Run Automatic
      Configuration, then rerun
      Advanced Diagnostics
  
000291XX 000292XX 1. Run Automatic Configuration
000293XX 000294XX     then rerun Advanced Diagnostics
(Checksum value mismatch)
000295XX 000296XX 1. System Board Memory
(Check memory for an unsupported
configuration or modules)
00029800 1. System Board Memory
(Checksum value mismatch)     Run Automatic Configuration
      then rerun Advanced Diagnostics
  
0002XX00 1. 486DX33 Upgrade (70/80)
(not listed above)
000301XX 000302XX 1. Keyboard Cable
  2. System Board
  
000303XX 000304XX 1. System Board
  2. Keyboard
  3. Keyboard Cable
  
000305XX 1. Fuse
(Keyboard voltage error. If no fuse in system 2. Keyboard Cable
replace system board)
000306XX 1. Check for Unsupported Keyboard
(Wrong Keyboard attached ?)
000307XX 1. Keyboard
  2. Keyboard Cable
  
000320XX 1. System Board
  
000401XX to 000405XX 1. System Board
  
0005XXXX 1. Display Adapter (any type)
  
000601XX 1. Defective Diskette
  2. Diskette Drive
  2. System Board
  
000602XX 1. Defective Diskette
(Invalid boot record)
000604XX 1. Diskette Drive
(Unsupported drive or cable. 2. System Board
Drive must be media sense type) 3. Diskette Drive Cable
  
000605XX 1. Run Advanced Diagnostics
(Diskette drive error)
000606XX 000607XX 1. Diskette
000610XX 000621XX 2. Diskette Drive
000622XX 000623XX 3. System Board
000624XX 000630XX
000631XX 000632XX
000633XX 000640XX
000641XX 000642XX
000643XX 000650XX
000651XX 000652XX
000653XX 000654XX
000656XX 000657XX
000658XX 000659XX
000660XX
(Generally, these are media errors.
Try a known good diskette. if the
error appears again, replace the drive.)
000655XX 1. System Board
  
000662XX     (Information only)
(Wrong drive type installed)
000663XX     (Information only)
(Wrong media type in the drive)
000668XX 1. Diskette Drive
  
0006XXXX 1. Diskette Drive
(not listed above) 2. System Board
  3. Diskette Drive Cable
  
0007XXXX 1. Math Coprocessor
For a 486 processor , erase COPROC.DGS 2. 486DX33 Upgrade (70/80)
from the backup Reference Diskette, then 3. System Board
restore the system partition from the
corrected backup Reference Diskette.
Re-run Advanced Diagnostics.
00265     (Information only)
(Ethernet Adapter terminator not connected)     (Thin/Thick or Twisted Terminator)
  
00100203 1. System Board
  
00110100 1. Run Advanced Diagnostics
(Serial connector error, possible system
board failure)
001101XX 00110200 1. System Board
00110600 00110800 2. Any Serial Device
00110900
001102XX 1. Run Advanced Diagnostics
(Card selected feedback error)
001103XX 1. Run Advanced Diagnostics
(Port fails register check) 2. System Board
  
001106XX 1. Run Advanced Diagnostics
(Serial option cannot be turned off) 2. System Board
  
001107XX 1. Serial Device Cable
  2. System Board
  
001110XX 1. Run Advanced Diagnostics
(Register test failed) 2. System Board
  
001116XX 1. Run Advanced Diagnostics
(16550 interrupt error)
001117XX 1. Run Advanced Diagnostics
(Failed baud rate test)
0011XXXX 1. System Board
(not listed above)
(See 'Power Supply Voltage Check'
before replacing system board)
001201XX 1. System Board
(Check voltages) 2. Any Serial Device
  
001202XX 001206XX 1. Dual Async Adapter/A
001208XX 001209XX 2. System Board
0012XXXX 3. Any Serial Device
  
001207XX 1. Communications Cable
  2. Dual Async Adapter/A
  
00129020 1. Cached Processor Option
(Disk cache error) 2. System Board
  
001301XX 001302XX 1. Game Adapter
  2. Joystick
  
001402XX     (Information only)
(Printer not ready)
001403XX     (Information only)
(No paper error, or interrupt failure)
001404XX 1. Run Advanced Diagnostics
(System board timeout failure)
001405XX 1. Run Advanced Diagnostics
(Parallel adapter error)
001406XX 1. Run Advanced Diagnostics
(Presence test error)
0014XXXX 1. Printer
(not listed above) 2. System Board
(Check printer before replacing
system board
001701XX 001703XX 1. Hard Disk Drive
001704XX 001714XX 2. Cable (ST506)
0017XXXX 3. Hard Disk Adapter (ST506)
(Not listed below) 4. System Board
  5. Power Supply
  
001702XX 1. Hard Disk Adapter
  
001705XX 001706XX 1. Format the Drive
001707XX 001708XX 2. Hard Disk Drive
001710XX 001711XX
001712XX 001713XX
001715XX 001716XX
001717XX 001726XX
001735XX 001750XX
001751XX 001752XX
001753XX 001754XX
001755XX 001757XX
001780XX 001781XX
001782XX 001790XX
001791XX
(Read/write problem. Be sure the
drive type is supported. If it is, try
a low level format. If the error continues,
replace the hard disk drive)
00180100 to 00180700 1. System Board
  
00186XXX 1. Set Configuration/Features
  2. Battery
  
0018XXXX 1. System Board
(not listed above)     Expansion Unit
  
00240100 00240200 1. Display (any type)
(If screen colors change)
00240100 00240200 1. System Board
(If screen colors are OK) 2. Display (any type)
  
00240900 1. Display (any type)
  
00241000 1. System Board
  
003015XX 1. Baseband Adapter
(Check for missing wrap or terminator 2. Baseband Cable
plug on the adapter)
0037XXXX 1. System Board
(This is usually caused by the 2. Hard Disk
SCSI controller built into the 3. Hard Disk Cable
system board.
004611XX 004630XX 1. Multiport/2 Interface Board
  2. Multiport/2 Adapter
  
004612XX 004613XX 1. Memory Module Package
004640XX 004641XX 2. Multiport/2 Adapter
  
00465000 004613XX 1. Multiport Interface Cable
  
0046XXXX 1. Multiport/2 Adapter
(not listed above) 2. Multiport/2 Interface Board
  3. Memory module Package
  
005600XX 1. Financial System
  2. Controller Adapter
  
0062XXXX 1. 1st Store Loop Adapter
  2. Adapter Cable
  
0063XXXX 1. 2nd Store Loop Adapter
  2. Adapter Cable
  
0064XXXX 1. Network Adapter
(See 'Network Service Procedures')
0071XXXX 1. Voice Adapter
  
0074XXXX 1. 8514/A Display Adapter
(Adapter jumper in the correct position ?     8514/A Memory Module
See 'Display Adapter 8514/A') 2. System Board
  
007509XX 1. Display Adapter (any type)
(Check display) 2. Display (any type)
  3. System Board
  4. Video Memory
  
007510XX 1. XGA Adapter
(Check display) 2. Video Memory
  
0076XXXX 1. Page Printer Adapter
  
0078XXXX 1. High Speed Adapter
  
0079XXXX 1. 3117 Adapter
  
00800100 to 008012XX 1. Pointing Device (Mouse)
(System Board Upgrade Model 50, 55 Only) 2. System Board
  
00850X00 00851XXX 1. 80286 Memory Option Adapter/A
  2. System Board
  
00852X00 00851XXX 1. Memory Module Package on
      the 80286 Memory Adapter/A
  2. Adapter Memory
  3. System Board
  
00860100 008602XX 1. Pointing Device (Mouse)
  2. System Board
  
008603XX 008604XX 1. System Board
  2. Pointing Device (Mouse)
  
0089XXXX 1. Music Adapter
  
0091XXXX 1. Optical Drive
  2. Adapter
  
0096XXXX 1. SCSI Adapter
(This adapter has cache) 2. Any SCSI Device
  3. System Board
  
010001XX     (Information only)
(Multiprotocol Adapter/A not found)
010002XX 1. Run Advanced Diagnostics
(Card selected feedback error)
010007XX 1. Communications Cable
  2. Multiprotocol Adapter/A
  
010008XX 010009XX 1. Multiprotocol Adapter/A
  2. Any Serial Device
  
0100XXXX 1. Multiprotocol Adapter/A
(not listed above) 2. System Board
  3. Bus Adapter
  
0101102X 0101106X 1. Modem Adapter/A
0101108X 0101109X 2. Data/Fax Modem
  3. Any Serial Device
  
010101XX 010102XX 1. Have the customer verify
010104XX 010105XX     that the correct operating
010106XX 010107XX     system device drivers are
010108XX 010109XX     installed and operational
010111XX 010112XX 2. Modem
010103XX 010114XX
010105XX 010116XX
010103XX 010110XX 1. System Board
0101171X 2. Data/Fax Modem
  
010117XX 1. Check system speaker
(not listed above) 2. Check PSTN cable
  3. External DAA if installed
  4. Modem
  
010118XX 1. Run System Diagnostics and
      verify the correct operation of
      the modem slot
  2. Modem
  
010119XX 1. Diagnostics detected a
      Non-IBM modem
  2. Modem
  
010120XX 1. Check PSTN Cable
  2. External DAA (if installed)
  3. Modem
  
010132XX 010133XX 1. Modem
010134XX 010135XX
010136XX 010137XX
010138XX 010139XX
010140XX 010141XX
010142XX 010143XX
010144XX 010145XX
010146XX 010147XX
010148XX 010149XX
010150XX 010151XX
010152XX
010153XX 1. Data/Fax Modem
  2. System Board
  
0101XXXX 1. Modem Adapter/A
(not listed above) 2. Data/Fax Modem
  3. System Board
  
010450XX 010451XX 1. Run Advanced Diagnostics
010490XX 010491XX 2. Riser Card (if installed)
010492XX 010499XX 3. Hard Disk Drive
(Read/write error) 4. System Board
  
010452XX 1. Run Advanced Diagnostics
(Seek test error)
010453XX     (Information only)
(Wrong drive type ?)
010454XX 1. Run Advanced Diagnostics
(Sector buffer test error)
010455XX 010456XX 1. Run Advanced Diagnostics
(Controller error)
010459XX     (Information only)
(Drive diagnostic command error)
010461XX 1. Run Advanced Diagnostics
(Drive format error)
010462XX 1. Run Advanced Diagnostics
(Controller seek error)
010464XX 1. Run Advanced Diagnostics
(Hard Disk read error)
010467XX 1. Run Advanced Diagnostics
(Drive non fatal seek error)
010468XX 1. Run Advanced Diagnostics
(Drive fatal seek error)
010469XX 1. Run Advanced Diagnostics
(Drive soft error count exceeded)
010470XX 010471XX 1. Run Advanced Diagnostics
010472XX
(Controller wrap error)
010473XX     (Information only)
(Corrupt data. Low level might be required
010480XX 1. Hard Disk Drive (ESDI)
  2. Drive Cable
  3. Controller
  4. System Board
  
010481XX 1. Run Advanced Diagnostics
(ESDI drive D seek error)
010482XX 1. Run Advanced Diagnostics
(Drive select acknowledgement bad)
010490XX 010491XX 1. Run Advanced Diagnostics
(Drive 0,1 read error) 2. Riser Card (If installed)
  3. Hard Disk Drive
  4. System Board
  
010499XX 1. Run Advanced Diagnostics
(Drive controller error) 2. Riser Card (If installed)
  3. Hard Disk Drive
  4. System Board
  
010483XX 1. Hard Disk Adapter (ESDI)
  2. System Board
  
0104XXXX 1. Hard Disk Drive
(not listed above) 2. Hard Disk Adapter (ESDI)
  3. Hard Disk Cable
  4. Power Supply
  
0106XXXX 1. Ethernet Network Adapter/A
(See 'Network Service Procedures') 2. System Board
  3. Bus Adapter
  
0107XXXX 1. 5.25-Inch External Diskette Drive
  2. 5.25-Inch Diskette Drive Adapter/A
  
0109XXXX 1. ActionMedia Adapter/A
(Check the adapter cables) 2. System Board
  
0112XXXX 1. SCSI Adapter
(This adapter does not have cache) 2. Any SCSI Device
  3. System Board
  
0119XXXX 1. 3119 Adapter
  
0121XXXX 1. 300/1200/2400 Modem/A
  2. Any serial Device
  3. System Board
  
01290001 01290002 1. Run Advanced Diagnostics
01290003 01290002
01290007 01290002
(Possibly a recoverable processor board error)
01290050 01290051 1. Processor Board
01290052 01290053 2. System Board
01290054 01290055
01290056
(Probably a fatal error)
01290100 012902XX 1. Processor Board
01290400 01290700 2. System Board Cache
01290800 3. System Board
(Cache error)
012903XX 1. Math Coprocessor
(Math Coprocessor error) 2. Processor Board
  
01290XXX 1. Processor Cache
(not listed above) 2. Processor Board
  3. System Board
  
01291200 01291300 1. Run Advanced Diagnostics
01291400 012915XX
012916XX 01291800
01291900 01294040
01294041
(Possible processor Board error)
01291700 1. Processor Board (90/95)
(If it is a 20 MHz board, and the
processor is a 487SX, the jumper must be
in positions 1 and 2) (487SX is indicated
on the processor)
01293000 1. Jumpered Incorrectly
(90/95 Processor board EEPROM jumper is 2. Processor Board
in the wrong position)
01294042 1. Processor Board
(POST / BIOS EEPROM error. Update
diskette is required)
01294400 1. Restart the system, then
(A hardware default interrupt occurred)     run Advanced Diagnostics
  
01295050 01295056 1. Restart the system, then
01295060 01295061     run Advanced Diagnostics
01295070 01295071
01295072 01295073
01295074 01295075
01295076 01295077
01295078 01295079
01295080 01295081
01295082 01295083
01295085 01295086
01295087 01295088
01295090 01295091
01295094 01295095
01295096 01295097
(Processor board errors)
0129X300 1. Busmaster Adapter (90/95)
(Busmaster arbitration error. If more 2. Processor Board
than one is installed, remove them
one at a time to isolate the failure)
01299000 1. Run Automatic Configuration
(VPD error, processor board replaced ?
Processor board serial number detected
does not match serial number stored)
0136XXXX 1. ISDN Primary Rate Adapter
  2. System Board
  
0137XXXX 1. System Board
  
0141XXXX 1. Realtime Interface Coprocessor
      Portmaster Adapter
  
0143XXXX 1. Japanese Display Adapter
  2. System Board
  
01471000 014711XX 1. System Board Display Adapter (any type)
  2. Adapter Video Memory
  
0148XX00 1. Display Adapter (any type)
  
014901XX 014902XX 1. Display Adapter (any type)
01491XXX 014922XX 2. System Board
  3. Display (any type)
  
014932XX 1. External Display (any type)
  2. Display Adapter (any type)
  
0152XXXX 1. XGA Display Adapter/A
  2. System Board
  
015302XX 1. S/370 Channel Emulator/A Adapter
  
015304XX 1. S/370 Channel Emulator/A Adapter
  2. S/370 Emulator/A Channel Cable
  
0161XXXX 1. FaxConcentrator Adapter/A
  
0164XXXX 1. 120MB Internal Tape Drive
  2. Diskette Cable
  3. System Board
  
016500XX 1. 6157 Tape Attachment Adapter
  
016520XX 016540XX 1. 6157 Streaming Tape Drive
  2. 6157 Tape Attachment Adapter
  
0166XXXX 0167XXXX 1. Token-Ring Network Adapter/A
(See 'Network Service Procedures') 2. System Board
  3. Bus Adapter
  
018001XX 1. Wizard Adapter
(18001 to 18029) 2. Wizard Adapter Memory
  
018031XX 1. Wizard Adapter Cable
(18031 to 18039)
018441XX     (Information only)
Unsupported memory module on 80386 adapter)
018451XX     (Information only)
(Need to reconfigure. Module changed
on 80386 adapter)
0184XXXX 1. Enhanced 80386 Memory Adapter/A
  
0185XXXX 1. DBCS Japanese Display Adapter/A
     2 System Board
  
0194XXXX 1. Memory Module Package on the
      2-8MB80286 Memory Adapter
  2. Memory adapter
  3. System Board
  
020001XX to 020003XX 1. Image Adapter/A
      Image-I Adapter/A
  2. Memory Module DRAM or VRAM
  
020004XX 1. Memory Module DRAM or VRAM
  2. Image Adapter/A Image-I Adapter/A
  
020005XX to 020010XX 1. Image Adapter/A
      Image-I Adapter/A
  2. Memory Module DRAM or VRAM
  
0200XXXX 1. Image Adapter/A
(not listed above)     Image-I Adapter/A
  2. Memory Module DRAM or VRAM
  3. System Board
  
020101XX to 020103XX 1. Printer/Scanner Option
  2. Image Adapter/A
  3. Memory Module DRAM or VRAM
  
020104XX 1. Memory Module DRAM or VRAM
  2. Printer/Scanner Option
  3. Image Adapter/A
  
020105XX to 020110XX 1. Printer/Scanner Option
  2. Image Adapter/A
  3. Memory Module DRAM or VRAM
  
Image Adapter/A Memory Test failure 1. Replace memory module
indicated by graphic representation     (shown in graphic)
of adapter
0206XXXX 1. SCSI-2 Adapter
  2. Any SCSI Device
  3. System Board
  
0208XXXX 1. Any SCSI Device
(Verify that there are no duplicate
SCSI ID settings on the same bus)
for Error Code Format see >    SCSI/Non-SCSI Error Code Format Codes
for 0210XXXX 9xxx Error's see >    SCSI Fixed Disk Diagn. Return Codes
  
0210XXXA (60MB) 1. SCSI Hard Disk Drive
0210XXXB (80MB) 2. SCSI Adapter or the SCSI controller
0210XXXC (120MB)     built into the system board.
0210XXXD (160MB) 3. SCSI Cable
0210XXXE (320MB) 4. SCSI ID Switch (On some models)
0210XXXF (400MB)
0210XXXG (40MB)
0210XXXH (1GB)
0210XXXI (104MB)
0210XXXJ (212MB)
0210XXXM (2GB 8 bit 68-pin)
0210XXXN (540MB)
0210XXXO (1GB)
0210XXXQ (540MB)
0210XXXP (2GB 8 bit 50-pin)
0210XXXU (Size unknown)
(If it is an external device, check the
external voltages.
See 'SCSI Diagnostic Tests' and
'SCSI ID (Using to Help Isolate Failures'
before replacing any FRUs)
0210XXXX 1. SCSI Hard Disk Drive
(Internal bus, size unknown) 2. SCSI Adapter or the SCSI controller
    built into the system board
0210XXX1 3. SCSI Cable
(External bus, size unknown) 4. SCSI ID Switch (on some models)
  
The amber LED remains on. 1. Tape Drive
  2. SCSI Cable (internal)
  3. SCSI Adapter or the SCSI controller
      built into the system board.
  
The green 'in use' LED fails to come on. 1. Tape Drive
  2. SCSI Adapter or the SCSI controller
      built into the system board.
  3. SCSI Cable (internal)
      SCSI Cable (external)
  
The tape is automatically ejected from 1. Tape Cassette
the drive. 2. Drive
  
SCSI ID on the rotary switch does not 1. Rotary Switch Circuit Board
match the SCSI ID set in configuration. 2. Circuit Board Cable
(Verify the drive switches inside the cover 3. Tape Drive
are set to zero)
Tape sticks/breaks in the drive. 1. Tape Cassette
(Verify that the tapes used meet
ANSI standard X3B5)
0212XXXX 1. SCSI Printer
  2. Printer Cable
  
0213XXXX 1. SCSI Processor
  
0214XXXX 1. WORM Drive
  
0215XXXC 1. CD-ROM Drive I
0215XXXD     CD-ROM Drive II
0215XXXE     Enhanced CD-ROM Drive II
0215XXXU     Any CD-ROM Drive
If it is an external device, and the 2. SCSI Cable
power-on LED is off, check external voltages) 3. SCSI Adapter or the SCSI controller
      built into the system board.
  
0216XXXX 1. Scanner
  
0217XXXX 1. Rewriteable Optical Drive
(If it is an external device, and the 2. SCSI Adapter or the SCSI controller
power-on LED is off, check external voltages)     built into the system board.
  3. SCSI Cable
  
0218XXXX 1. Changer
(Check for multi CD tray, or juke box)
0219XXXX 1. SCSI Communications Device
  
024201Y0 024210Y0 1. ISDN/2 Adapter
(Be sure the wrap plug is not missing) 2. ISDN/2 Wrap Plug
  3. ISDN/2 Communications Cable
  
0243XXXX 1. XGA-2 Display Adapter
  
002460XX 1. 90 MHz Processor Upgrade
      (without VRAM)
  2. System Board
  
002461XX 1. 90 MHz Processor Upgrade
      (with 1MB VRAM)
  
0258XXXX 1. XGA-2 Display Adapter
Video might have failed. 2. System Board
(Ensure that you are using diagnostic files
XGAANI.DGS and XGAPNI.DGS dated 03/06/93
or later before you replace any FRUs.
Earlier files cause erroneous errors.)
0259XXXX 1. SVGA Adapter
  2. System Board
  
0260XXXX 1. System Board
  2. Any SCSI Device
  
0270XXXX 1. RAID Adapter Controller
  2. System Board
  
0271XXXX 1. RAID Hard Disk Drive
  2. System Board
  
0273XXXX 1. 1 Mbps MicroChannel Infrared
  2. LAN Adapter
  
027485Y0 1. LANStreamer MC 16 Adapter
      Configuration Compare failure
  
027490Y0 1. LANStreamer MC 16 Adapter
      Adapter Card Test failure
  
027491Y0 1. LANStreamer MC 16 Adapter
      Open Phase Test failure
  
027492Y0 1. LANStreamer MC 16 Adapter
      Computer Problem
  
027493Y0 1. LANStreamer MC 16 Adapter
      Transmit/Receive Test failure
      Check Adapter Cable/Wrap Plug
  
027499Y0 1. LANStreamer MC 16 Adapter
      General error
  
0274XXY0 1. LANStreamer MC 16 Adapter
      Y is SLOT # where Adapter installed
  2. System Board
  
027501XX 027503XX 1. ServerGuard Adapter
027506XX 027507XX 2. System Board
  
027502XX 027504XX 1. ServerGuard Adapter
027510XX 027511XX
027533XX 027534XX
027536XX 027537XX
027509XX 1. Remove redundant ServerGuard
      Adapters, run Auto Configuration
      program, then retest
  
027512XX 1. WMSELF.DGS diagnostics file missing
  2. WMSELF.DGS diagnostic file incorrect
  
027535XX 1. 3V Lithium Backup Battery
  2. ServerGuard Adapter
  
027554XX 1. Internal Temperature out of range
  2. ServerGuard Adapter
  
027555XX 027556XX 1. ServerGuard Adapter
  2. System Power Supply
  
027557XX 1. 7.2V NiCad Main Battery Pack
  2. ServerGuard Adapter
  
027558XX 027559XX 1. PCMCIA Type II Modem
027560XX 027561XX 2. ServerGuard Adapter
  
027562XX 1. External Power Control Box
      not connected
  2. External Power Control Box
  3. ServerGuard Adapter
  
027563XX 027564XX 1. External Power Control Box
  2. ServerGuard Adapter
  
0275XXXX 1. Update Diagnostic Software
  
027801X0 027859X0 1. Personal Voice Dictation Adapter/A
  
027861X0 027863X0 1. OS/2 Device Driver for Voice Dictation Adapter/A is missing
  
027864X0 1. Only one Voice Dictation PCMCIA Adapter is supported in a computer
  
027865X0 1. The PCMCIA enabler is unable to read the card information
  
027866X0 1. PCMCIA Card Socket Services not installed
  
027871X0 1. The VoiceType Dictation PCMCIA Card was not found
  
027880X0 027889x0 1. Check all Cables
(Speaker test failed) 2. Check external Speaker oper. control.
  
027890X0 027899x0 1. Check all Cables
(Microphone test failed) 2. Check Microphone operating control.
  
0279XXXX 1. Fast/Wide Streaming -
      - RAID Adapter/A (FRU 06H3059)
      Pass through Card & Cable
  2. System Board
  3. Signal Pass Through Card (if installed)
  
0281XXY0 1. Dual LANStreamer MC32 Adapter
Y = slot number     XX = 85 Configuration Compare failure
XX = type of error     XX = 90 Adapter Test Card failure
      XX = 91 Open Phase Test failure
      XX = 92 Computer Problem
      XX = 93 Transmit/Receive Test failure
      XX = 99 General error
  
I998009X 1. Restore System Partition
  
I999XXXX 1. Default Hard Disk Drive
(This is usually not a hardware failure. 2. Processor Board (90/95)
Go to IML and IPL Errors before replacing 3. SCSI Adapter
FRUs. Specific I999XXXX error codes 4. SCSI Cable
are listed after IML and IPL Errors
for SCSI 0210xxxx 9xxx (Fixed Disk DIAGNOSE) Errorcodes see > SCSI Return Error-Codes


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.