See > System Address Maps
1 Power Supply Connector (J3)
Power Connector (Voltages)
2 Flash Jumper (JP11)
3 FDD write Protect (JP21)
4 PS/2 Mouse Enable/Disable (JP4)
5 Diskette Drive Conn. (J5)
6 HDD Detect (JP23)
7 Primary IDE Hard Disk Drive Conn. (J8)
8 Secondary IDE Hard Disk Drive Conn. (J7)
9 Battery
10 Power-On Password/CMOS mode (J9)
(1-2 = Normal Operation 2-3 = CMOS Clear)
11 CACHE Memory Connectors
12 Burst Mode (JP22)
13 CPU Voltage (JP19)
14 Processor Socket
15a Hard Disk Drive LED Connector (J12)
15b Power LED Connector (J12)
16 CPU Fan Connector (J13)
17 CPU Clock (JP17)
18 Memory Module Connector 1 - Bank1
19 Memory Module Connector 2 - Bank1
20 Memory Module Connector 3 - Bank0
21 Memory Module Connector 4 - Bank0
22 Tag RAM Socket
23 Feature Connector (J6)
24 Cache Memory Size (JP13)
25 CPU Bus Clock (JP14)
26 On-Board VGA (JP3)
27 Display Connector (P4)
28 Parallel Connector (P1)
29 Video Memory Sockets
30 Serial Connector COM2 (P2)
31 PCI/ISA Riser Connector
32 Serial Connector COM1 (P3)
33 Mouse Connector (J2)
34 Keyboard Connector (J1)
Processor Type Selection Jumper (JP14 JP17)
Processor | JP14 | JP17 |
---|---|---|
P75 MHz 6260 | 1-2 | open |
P90 MHz 6260/6560 | 3-4 | open |
P100 MHz 6260/6560 | 1-2, 3-4 | open |
P120 MHz 6560 | 3-4 | 1-2 |
P133 MHz 6560 | 1-2, 3-4 | 1-2 |
P166 MHz 6560 | 1-2, 3-4 | 1-2, 3-4 |
Cache Size Selection Jumper (JP13)
Size | JP13 |
---|---|
256 KB (D) or no Cache |
1-2 |
512 KB | 2-3 |
Miscellaneous Jumpers (JP3 JP4 J9 JP11 JP19 JP21 JP22 JP23)
Jumper | Setting | Description |
---|---|---|
JP3 | Short Open |
Enable on-board VGA (D) Disable on-board VGA |
JP4 | Short Open |
Enable PS/2 mouse (D) Disable PS/2 mouse |
J9 | 1-2 2-3 |
Normal (D) CMOS Data Clear (all setup data reset to default and Power-On-Password cleared) |
JP11 | 1-2 2-3 |
Enable Flash (D) Flash Lock |
JP19 | 1-2 2-3 |
STD 3.3 volt VRE 3.52 volt (D) |
JP21 | 1-2 2-3 |
FDD protect, Normal (D) FDD Write protect |
JP22 | 1-2 2-3 |
Non-Linear burst (D) Linear burst |
JP23 | 1-2 2-3 |
HDD non-detect HDD detect (D) |
You can install a maximum of four single inline memory modules (SIMMs)
in the computer. The system supports a minimum of 8 MB and a maximum of 128 MB
of memory. Use only tin lead, 72-pin, 60ns Industry Standard EDO, non-parity SIMMs.
Memory modules are installed in two memory banks, Bank 0 and Bank 1. Each
bank supports 4, 8, 16 or 32 MB single or double-density SIMMs. Each bank used, must contain
a pair of SIMMs of the same size and density. For best performance, fill Bank 0 first.
The following table shows some possible SIMM combinations and the total memory size for each combination.
See also Memory Matrix
Bank 0 SIMM 1 |
Bank 0 SIMM 2 |
Bank 1 SIMM 3 |
Bank 1 SIMM 4 |
Total |
---|---|---|---|---|
4 MB (single) |
4 MB (single) |
- | - | 8 MB |
4 MB (single) |
4 MB (single) |
4 MB (single) |
4 MB (single) |
16 MB |
8 MB (double) |
8 MB (double) |
- | - | 16 MB |
8 MB (double) |
8 MB (double) |
8 MB (double) |
8 MB (double) |
32 MB |
16 MB (single) |
16 MB (single) |
- | - | 32 MB |
8 MB (double) |
8 MB (double) |
16 MB (single) |
16 MB (single) |
48 MB |
16 MB (single) |
16 MB (single) |
16 MB (single) |
16 MB (single) |
64 MB |
32 MB (double) |
32 MB (double) |
- | - | 64 MB |
32 MB (double) |
32 MB (double) |
4 MB (single) |
4 MB (single) |
72 MB |
32 MB (double) |
32 MB (double) |
8 MB (double) |
8 MB (double) |
80 MB |
32 MB (double) |
32 MB (double) |
16 MB (single) |
16 MB (single) |
96 MB |
32 MB (double) |
32 MB (double) |
32 MB (double) |
32 MB (double) |
128 MB |