If a SCSI device is missing from the list, determine if the missing device is connected to the SCSI controller on the system board, or a SCSI adapter. Either the system board or the SCSI adapter might be defective. Continue with the following procedure.
SCSI - Errorcode format
A A A B C D E F F F
----+ | | | | +----
| | | | | Error code (see table)
| | | | Unit capacity (always 0)
| | | Defective Adapter (primary = 0)
| | Logical Unit number (Adapter = 0)
| SCSI - ID of Unit (Adapter = 7)
|
Unit-type
Unit-type Codes:
104 IBM PS/2 SCSI-2 Adapter/2
209 DASD-Unit type 0 (not 512 bytes / sector not replaceable)
210 Hard Disk (512 byte / sector)
211 Unit with sequ. access (Tape)
212 Printer
213 Processor
214 WORM-Unit (Write Once Read Many)
215 CD-ROM
216 Scanner
217 Optical Storage
Error code Example for EC 1047000 107
104 Unit is IMB PS/2 SCSI-2 Adapter/A
7000 SCSI - ID is 7 .... Primary Adapter
107 Error Code 107
SCSI - Error Code table
Error Code: | FRU/Action. |
---|---|
107 | 1. SCSI chain not correct terminated |
2. Cable not correct installed | |
3. defective SCSI cable | |
4. defective SCSI terminator | |
5. defective SCSI device | |
6. defective SCSI-2 Adapter/A | |
220 | 1. Configuration Error |
2. SCSI - ROM system-memory conflict | |
3. SCSI-2 Adapter/A | |
221 | 1. No SCSI Device found |
2. SCSI cable defect | |
3. SCSI - Device Power missing | |
4. SCSI - termination | |
6. SCSI-2 Adapter/A | |
402 | 1. SCSI Device Error |
XXX | 1. Unknown SCSI Device |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.