Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric ERROR CODES AT Bus


  Numeric ERROR CODES AT Bus

Symptom/Error:    FRU/Action.
  
101    Interrupt failure
  
102    Timer failure
  
103    Timer-Interrupt failure
  
104    Protected-mode failure
  
105    Last 8042 CMD not accepted
     (keyboard controller)
  
107    NMI test failed
  
108    Timer bus test failed
  
109    Low MB chip select test
  
110    System Board parity 1
     (system board parity latch set)
  
111    I/O parity 2
     (I/O channel-check latch set)
  
112 113    I/O channel check error
  
114    External ROM checksum error
  
115    DMA error
  
116    System board port read/write error
  
120    Microprocessor test error
  
131XX    (Information only)
(Cassette wrap failure)
161 163 165 1. Set Time and Date
  2. Bus Adapter
  3. Clock Module
  4. Battery
  5. System Board
  
162 1. Run Setup
      Run Automatic Configuration
  2. Clock Module
  3. System Board
  
162 1. Diskette Drive
(and unable to run 2. System Board
advanced diagnostics) 3. Diskette Drive Cable
  
164 1. Run Setup
(Check memory)     Run Automatic Configuration
  2. System Board
  
199 1. Any Device
  
1XX 1. System Board
  
201 1. Memory Data Error
(Check all Memory/Adapter)
2XX 1. System Board
(Check Memory/Adapter)
302 1. Is the Keylock locked ?
  2. Keylock Assembly
  3. System Board
  
305 1. Systemboard non replaceable Fuse
  2. Keyboard/Cable (+5V OK ?)
  3. Mouse
  4. System Board
  
3XX 1. Keyboard
(not listed above) 2. System Board
  3. Keyboard Cable
  
5XX 1. System Board
  2. Display Adapter
  
601 1. System Board
Diskette drive controller error
61X 1. Diskette Drive Cable
 
Diskette drive test error 2. Diskette Drive
  3. System Board
  
602 1. System Board
  2. Diskette Drive
  3. Diskette Drive Cable
  
604 662 1. Wrong Diskette Drive Type
  
663 1. Wrong Media Type
  
6XX 1. Diskette Drive
(not listed above) 2. External Drive Adapter
  3. System Board
  4. Power Supply
  5. Display Assembly (8525)
  6. Diskette Drive Cable
  
7XX 1. Math Coprocessor
  2. System Board
  
9XX 1. Printer
  2. System Board
  
1002 1. Alternate Parallel Adapter-Jumpers
  1. Alternate Parallel Adapter
  
1047 1. 16 Bit AT SCSI Fast Adapter
  
10XX 1. Alternate Parallel Adapter
(not listed above) 1. Bus Adapter
  
11XX 1. System Board
  
1202 1. Alternate Serial Adapter-Jumpers
  2. Alternate Serial Adapter
  3. Bus Adapter
  
12XX 1. Alternate Serial Adapter
  2. Bus Adapter
  
13XX 1. Game Control Adapter
  2. Bus Adapter
  
14XX 1. Printer
  
15XX 1. SDLC Adapter
  2. Bus Adapter
  
16XXXX 1. 36/38 Workstation Adapter
  
17XX 1. Hard Disk Drive
(Model 9533 systems may produce 2. System Board
false 1702 and 1713 error. 3. Hard Disk Cable
If no other symptoms are detected 4. Power Supply
ignore these errors.) 5. Display Assembly (8525)
  
209X 1. Diskette Drive
  2. Diskette Drive Cable
  3. 16 Bit AT SCI Fast Adapter
  
20XX 1. BSC Adapter
 
(not listed above) 2. Bus Adapter
  
21XX 1. SCSI Device
  2. 16 Bit AT SCSI Fast Adapter
  3. Alternate BSC Adapter
  4. Bus Adapter
  
2401 2402 1. Display
(If screen colors change)
2401 2402 1. System Board
(If screen colors are OK) 2. Display
  
2408 1. System Board
  
2409 1. Display
  
2410 1. System Board
  2. Display
  
24XX 1. Optional Video Memory
Video/monitor error 2. System Board
  3. Monitor
  
28XX 1. 3278/79 Adapter
  2. Coaxial Cable
  3. Bus Adapter
  
3015 3040 1. Network Attached ?
  2. LF Translator
  3. Cable Problem
  4. PC Network Adapter
  5. Bus Adapter
  
30XX 1. PC Network Adapter
  2. LF Translator
  3. Cable Problem
  4. Bus Adapter
  
3115 3140 1. Network Attached ?
  2. LF Translator
  3. Alternate PC Network Adapter
  4. Cable Problem
  5. Bus Adapter
  
31XX 1. Alternate PC Network Adapter
  2. LF Translator
  3. Cable Problem
  4. Bus Adapter
  
36XX 1. GPIB Adapter
  2. Bus Adapter
  
38XX 1. DAC Adapter
  2. Bus Adapter
  
5962 1. CD-ROM drive Connection/Jumper
CD-ROM configuration error 2. CD-ROM Drive
  3. Power Supply
  4. System Board
  
64XX 1. Ethernet Adapter
(See 'Network Service Procedures')
74XX 1. Display Adapter
  2. Bus Adapter
  
80XX 1. PCMCIA Adapter
  
84XX 1. Speech Adapter
  2. Speech Control Assembly
  3. Bus Adapter
  
85XX 1. 2MB Exp. Memory Adapter
  2. Bus Adapter
  
8601 1. System Board
  2. Keyboard / Mouse
  
8602 1. Pointing Device Error
  2. System Board
  
86XX 1. Pointing Device
  2. System Board
  
89XX 1. PC Music Adapter
  2. MIDI Adapter Unit
  2. Bus Adapter
  
106X1 1. Set Configuration
  2. Ethernet Adapter
  
10635 1. Power-off the computer,
      wait six seconds, then
      power-on the computer.
  2. Ethernet Adapter
  
10651 10660 1. Check Cables
  2. Ethernet Adapter
  
106XX 1. Ethernet Adapter
(not listed above)
(see 'Network Service Procedures')
12101 1. ISDN adapter error detected
      (in Customer mode)
  
12110 XXXX or 12120 XXXX 1. Defective ISDN Adapter
  
12120 006B 1. Defective ISDN Wrap Connector
  2. Missing ISDN wrap connector
  3. Defective ISDN Adapter
  
12902 1. Intel® Chip Level-1 cache error
  
12904 1. Level-2 cache error
  
129XX 1. Processor Board
  2. Cache Kit
  
166XX 167XX 1. Token Ring Adapter
(see 'Network Service Procedures') 2. System Board
  3. Bus Adapter (if used)
  
243XX 1. System Board
  
027801X0 to 027859X0 1. Personal Voice Dictation Adapter
  2. System Board
  
027880XX to 027889XX 1. External FRU (Speaker, Microphone)
  
I9990301 1. Hard disk drive failure
  
I9990305 1. No Operating System found
  
I999XXXX 1. Default Hard Disk
(There is an optional SCSI adapter 2. SCSI Cable
installed) 3. SCSI Cable


More INFORMATION / HELP is available at the  IBM-HelpCenter