POST Error | FRU/Action |
---|---|
Code/Symptom | |
101 | 1. System Board |
System board interrupt failure. | |
102 | 1. System Board |
System board timer error. | |
106 | 1. System Board |
110 | 1. Memory Module |
System board memory parity error. | 2. System Board |
111 | 1. Reseat adapters |
I/O channel parity error. | 2. Any Adapter |
3. System Board | |
114 | 1. Adapter Memory |
Adapter ROM error. | 2. System Board |
151 | 1. System Board |
Real-time clock failure. | |
161 | 1. Run Setup |
Bad CMOS battery. | 2. CMOS Backup Battery |
3. System Board | |
162 | 1. Run Setup and verify Configuration |
Configuration mismatch. | 2. Had a device been added, removed, changed location? |
If not, suspect that device. | |
3. Power-on external devices first, then power-on computer. | |
4. CMOS Backup Battery | |
5. System Board | |
163 | 1. Time and Date Set? |
Clock not updating | 2. CMOS Backup Battery |
or invalid time set. | 3. System Board |
164 | 1. Run Setup. Check System Summary menu for memory size change. |
POST detected a base memory or | 2. Run the Extended Memory Diagnostic tests. |
extended memory size mismatch error. | |
167 | 1. Update the Flash BIOS to the latest level |
Microprocessor installed that is not | 2. Processor |
supported by the current POST/BIOS. | |
168 | 1. Run Setup. Check to see that Ethernet and Alert on LAN are enabled. |
Alert on LAN error | 2. System Board |
3. Riser Card, if installed. | |
175 | 1. Run Configuration |
2. System Board | |
176 | 1. Covers were removed from the computer. |
177 | 1. System Board |
Corrupted | |
Administrator Password. | |
17X not listed above | 1. C2 Security |
183 | 1. Enter the administrator password |
184 | 1. Make sure Asset Care and Asset ID are disabled in |
RFID Antenna Installed | Configuration/Setup. An RFID Antenna should not be installed. |
186 | 1. System Board |
187 | 1. Clear Administration password |
2. System Board | |
18X not listed above | 1. C2 Security |
190 | 1. System Board |
Chassis intrusion detector | 2. Riser Card, if installed |
was cleared. | |
This is information only, | |
no action required. | |
If this code does not clear: | |
20X | 1. Run Enhanced Diag. Memory Test |
Memory data error. | 2. Memory Module |
3. System Board | |
301 | 1. Keyboard |
2. Keyboard Cable | |
3. System Board | |
303 | 1. Mouse |
With an 8603 error. | 2. Keyboard |
3. Keyboard Cable | |
4. System Board | |
303 | 1. Keyboard |
With no 8603 error. | 2. Keyboard Cable |
3. System Board | |
601 | 1. Diskette Drive A |
2. Diskette Drive Cable | |
3. Riser Card, if installed | |
4. System Board | |
602 | 1. Bad Diskette |
2. Verify Diskette and retry. | |
604 | 1. Run Setup and verify diskette configuration settings |
2. Diskette Drive A/B | |
3. Diskette Drive Cable | |
4. Riser Card if drive cable connected | |
5. System Board | |
662 | 1. Diskette drive configuration error or wrong diskette drive type, |
run Setup Configuration. | |
762 | 1. Run Setup |
Math coprocessor | 2. Processor |
configuration error. | 3. System Board |
11XX | 1. Serial Cable |
Serial port error | 2. Serial device |
3. System Board | |
1762 | 1. Run Configuration |
Hard disk drive | |
configuration error. | |
1780 (Disk Drive 0) | 1. See Power Supply |
1781 (Disk Drive 1) | 2. Hard Disk Drive |
1782 (Disk Drive 2) | 3. Riser Card, if hard disk cable connected |
1783 (Disk Drive 3) | 4. System Board |
5. Hard Disk Cable | |
6. Power Supply | |
180X, 188X | 1. Run Setup and verify PCI/ISA configuration settings. |
PCI configuration | 2. If necessary, set ISA adapters to 'Not available' to allow |
or resource error. | PCI adapters to properly configure. |
3. Remove any suspect ISA adapters. | |
4. Rerun diagnostics. | |
5. PCI Adapter | |
6. PCI Riser Card | |
1962 | 1. Run Configuration/Setup, check Boot Sequence. |
Boot sequence error. | 2. Check cable connections. |
3. Run Diagnostics. | |
4. Hard Disk Drive | |
5. System Board | |
2462 | 1. Check cable connections. |
Video memory configuration | 2. Run Setup and verify video configuration settings. |
error. | 3. Video Memory Modules |
4. Video Adapter (if installed) | |
5. System Board | |
5962 | 1. Run Configuration |
An IDE device (other than | 2. CD-ROM Drive |
hard drive) configuration | 3. CD-ROM Adapter |
error. | 4. ZIP or other ATAPI device |
5. System Board | |
8601, 8602 | 1. Pointing Device (Mouse) |
2. System Board | |
8603, 8604 | 1. System Board |
2. Pointing Device (Mouse) | |
86XX | 1. Mouse |
Not listed above | 2. System Board |
I999030X | Possible hard disk drive problem |
Hard disk reset failure | |
Error not listed above | Follow the instructions on the screen |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.