| Problem | FRU/Action |
|---|---|
| 1XXX (Microcode Checksum Error) | 1. PC ServeRAID 3L Adapter/Controller |
| 2XXX thru 5XXX (Code DRAM Error) | 1. Install download jumpers, flash latest level BIOS and firmware for adapter, then remove jumpers. 2. PC ServeRAID 3L Adapter/Controller |
| 6XXX (Cache DRAM Error) | 1. Reseat Cache memory SIMM 2. Install download jumpers, flash latest level BIOS and firmware for adapter. Remove jumpers. 3. ServeRAID 3L Adapter/Controller |
| 7XXX thru 8XXX (Host/Local PCI Bus Interface Error) | 1. Install download jumpers, flash latest level of BIOS and firmware for adapter. Remove jumpers. 2. ServeRAID 3L Adapter/Controller |
| 9XXX thru BXXX SCSI Bus error caused by defective drives, termination, etc.) | 1. Refer to POST (ISPR) Error Procedures 2. SCSI cable 3. SCSI backplane 4. Hard drive 5. PC ServeRAID 3L Adapter/Controller |
| EF10 (default ISPR) | 1. Run diagnostics on DOS configuration program. |
| EFFE (Firmware code corrupt or download jumpers are in place) | 1. Refer to POST (ISPR) Error Procedures |
| FFFF or other code not listed | 1. Refer to POST (ISPR) Error Procedures 2. SCSI cable 3. SCSI backplane 4. Hard drive 5. PC ServeRAID 3L Adapter/Controller |
Please see the LEGAL - Trademark notice.
Feel free - send a