SMBUS Error (Beep Code 3-3-2) (Netfinity 7000-M10 - Type 8680)
SMBUS Error (Beep Code 3-3-2)
Note: The minimum system configuration required to force
power-on the system using I/O board jumper J7 is:
   -  One bank of memory on one memory card with terminator
   
 -  One processor with two VRMs and terminator card
   
 -  One power supply
 
If the system displays a 3-3-2 error and powering off, waiting for 20 seconds,
then, powering on the system does not correct the problem, do the following:
   -  Connect remotely to the system and check the system error log.
   
 -  Remove the system management card.
   
 -  Disconnect the front panel cable form the I/O function card.
   
 -  Disconnect the SCSI power cable.
   
 -  Remove/disable all adapters.
   
 -  Jumper J7 on the I/O board, then, power-on the server.
   
 -  If the server starts, replace the components one at a
 time in the order in which they were removed, until you isolate the defective FRU.
   
 -  If the server does not start with the minimum required
 configuration, replace the following FRUs in the order listed.
   -  Power control card
   
 -  Processor board
   
 -  I/O board
   
 -  Power backplane
   
 -  I/O function card
 
 