Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

SCSI LEDs - SCSI Error Codes (Netfinity 7000-M10 - Type 8680)



SCSI LEDs - SCSI Error Codes

SCSI LEDs

Check the status LED. If on, do the following:
  1.  Check the internal SCSI cable.
  2.  Replace the failing hard disk drive.
  3.  Replace the SCSI backplane.
  4.  Replace the hard disk drive controller (PCI adapter or I/O Function card).


SCSI Error Codes
Error Code    FRU/Action
  
All SCSI Errors 1. External SCSI devices must be powered-on before
One or more of the following     you power-on the server.
might be causing the problem: 2. The cables for all external SCSI devices are connected correctly.
° A failing SCSI device 3. If you have attached an external SCSI device to the server,
(adapter, hard drive, controller)     make sure the external SCSI termination is set to automatic.
° An improper SCSI 4. The last device in each SCSI chain is terminated correctly.
configuration or SCSI 5. The SCSI devices are configured correctly.
termination jumper setting
° Duplicate SCSI IDs in
the same SCSI chain
° A missing or improperly
installed SCSI terminator
° A defective SCSI terminator
° An improperly installed cable
° A defective cable


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.