SCSI Error Codes
Error Code | FRU/Action |
---|---|
All SCSI Errors | 1. External SCSI devices must be powered-on before |
One or more of the following | you power-on the server. |
might be causing the problem: | 2. The cables for all external SCSI devices are connected correctly. |
° A failing SCSI device | 3. If you have attached an external SCSI device to the server, |
(adapter, hard drive, controller) | make sure the external SCSI termination is set to automatic. |
° An improper SCSI | 4. The last device in each SCSI chain is terminated correctly. |
configuration or SCSI | 5. The SCSI devices are configured correctly. |
termination jumper setting | |
° Duplicate SCSI IDs in | |
the same SCSI chain | |
° A missing or improperly | |
installed SCSI terminator | |
° A defective SCSI terminator | |
° An improperly installed cable | |
° A defective cable |
Please see the LEGAL - Trademark notice.