| Error Code/Symptom | FRU/Action | 
|---|---|
| 001-XXX-XXX | 1. I/O Function Card | 
| (Failed core tests) | 2. I/O Board | 
| 005-XXX-XXX | 1. I/O Function Card | 
| (Failed Video test) | 2. I/O Board | 
| 011-XXX-XXX | 1. I/O Function Card | 
| (Failed Serial Port test) | 2. I/O Board | 
| 014-XXX-XXX | 1. I/O Function Card | 
| (Failed Parallel Port test) | 2. I/O Board | 
| 015-XXX-XXX | 1. I/O Board | 
| (Failed USB test) | |
| 030-XXX-000 | 1. I/O Function Card | 
| (Failed Internal SCSI | 2. I/O Board | 
| interface test -channel 0) | |
| 030-XXX-001 | 1. I/O Function Card | 
| (Failed Internal SCSI | 2. I/O Board | 
| interface test -channel 1) | |
| 035-XXX-000 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 1 | 
| adapter in slot 1) | 3. SCSI Backplane | 
| 035-XXX-001 | 1. Fixed Disk 1 | 
| (Failed RAID test for Fixed | 2. SCSI Cable | 
| Disk in bay 1 SCSI ID 0) | 3. RAID Adapter | 
| Note 1 | 4. SCSI Backplane | 
| 035-XXX-001 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 2 | 
| adapter in slot 2) | 3. SCSI Backplane | 
| Note 1 | |
| 035-XXX-002 | 1. Fixed Disk 2 | 
| (Failed RAID test for Fixed | 2. SCSI Cable | 
| Disk in bay 2 SCSI ID 1) | 3. RAID Adapter | 
| Note 1 | 4. SCSI Backplane | 
| 035-XXX-002 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 3 | 
| adapter in slot 3) | 3. SCSI Backplane | 
| Note 1 | |
| 035-XXX-003 | 1. Fixed Disk 3 | 
| (Failed RAID test for Fixed | 2. SCSI Cable | 
| Disk in bay 3, SCSI ID 2) | 3. RAID Adapter | 
| Note 1 | 4. SCSI Backplane | 
| 035-XXX-003 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 4 | 
| adapter in slot 4) | 3. SCSI Backplane | 
| Note 1 | |
| 035-XXX-004 | 1. Fixed Disk 4 | 
| (Failed RAID test for Fixed | 2. SCSI Cable | 
| Disk in bay 4, SCSI ID 3) | 3. RAID Adapter | 
| Note 1 | 4. SCSI Backplane | 
| 035-XXX-004 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 5 | 
| adapter in slot 5) | 3. SCSI Backplane | 
| Note 1 | |
| 035-XXX-005 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 6 | 
| adapter in slot 6) | 3. SCSI Backplane | 
| 035-XXX-006 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 7 | 
| adapter in slot 7) | 3. SCSI Backplane | 
| 035-XXX-007 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 8 | 
| adapter in slot 8) | 3. SCSI Backplane | 
| 035-XXX-008 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 9 | 
| adapter in slot 9) | 3. SCSI Backplane | 
| 035-XXX-009 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 10 | 
| adapter in slot 10) | 3. SCSI Backplane | 
| 035-XXX-010 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 11 | 
| adapter in slot 11) | 3. SCSI Backplane | 
| 035-XXX-011 | 1. SCSI Cable | 
| (Failed RAID test for | 2. RAID Adapter 12 | 
| adapter in slot 12) | 3. SCSI Backplane | 
| 089-XXX-001 | 1. Processor 1 | 
| (Failed Microprocessor test) | 2. VRMs | 
| 3. Processor Board | |
| 089-XXX-002 | 1. Processor 2 | 
| (Failed Microprocessor test) | 2. VRMs | 
| 3. Processor Board | |
| 089-XXX-003 | 1. Processor 3 | 
| (Failed Microprocessor test) | 2. VRMs | 
| 3. Processor Board | |
| 089-XXX-004 | 1. Processor 4 | 
| (Failed Microprocessor test) | 2. VRMs | 
| 3. Processor Board | |
| 165-XXX-000 | 1. System Management Card | 
| (Failed System | 2. System Management Card Cable | 
| Management Card test) | 3. I/O Function Card | 
| 170-XXX-XXX | 1. System Management Card | 
| (Voltage sensor test failed) | 2. System Management Card Cable | 
| 3. Power Control Card | |
| 175-XXX-XXX | 1. System Management Card | 
| (Thermal sensor test failed) | 2. System Management Card Cable | 
| 180-XXX-000 | 1. System Management Card | 
| (LED test failed) | |
| 180-XXX-001 | 1. Front Panel | 
| (LED test failed) | 2. System Management Card | 
| 180-XXX-002 | 1. Memory Card 1 | 
| (LED test failed) | 2. System Management Card | 
| 180-XXX-003 | 1. Memory Card 2 | 
| (LED test failed) | 2. System Management Card | 
| 180-XXX-004 | 1. I/O Board | 
| (PCI Power/Attention LED | |
| tests failed) | |
| 180-XXX-005 | 1. PCI Sensor Card | 
| (Retention bracket failure) | 2. I/O Board | 
| 180-XXX-006 | 1. SCSI Cable | 
| (ASPI not loaded) | 2. SCSI Backplane | 
| 3. I/O Function Card | |
| 180-XXX-007 | 1. Cable | 
| (DASD LED failed, see | 2. DASD backplane | 
| message for slot) | |
| 185-XXX-001 | 1. Intrusion (C2 Security) Cable | 
| (Intrusion Security test | 2. Front Panel | 
| failed) | 3. I/O Function Card | 
| 185-XXX-002 | 1. Intrusion (C2 Security) Cable | 
| (Intrusion Security test | 2. Front Panel | 
| failed) | 3. I/O Function Card | 
| 201-XXX-000 | 1. Memory DIMM (see message for Card/DIMM) | 
| (Failed Memory Test) | 2. Memory Card | 
| 3. Processor Board | |
| 201-XXX-001 | 1. Memory DIMM (Verify failing FRU in system error log.) | 
| (Failed ECC test) | |
| 202-XXX-000 | 1. BSP Processor | 
| (Failed System Cache test) | 2. Processor Board | 
| 206-XXX-XXX | 1. Diskette Drive cable | 
| (Failed Diskette Drive test) | 2. Diskette Drive | 
| 3. I/O Function Card | |
| 215-XXX-000 | 1. CD-ROM cable | 
| (Failed CD-ROM test) | 2. CD-ROM drive | 
| 3. I/O Board | |
| 217-XXX-001 | 1. Fixed Disk 1 | 
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-002 | 1. Fixed Disk 2 | 
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-003 | 1. Fixed Disk 3 | 
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-004 | 1. Fixed Disk 4 | 
| (Failed BIOS Fixed Disk | |
| test) | |
| 301-XXX-XXX | 1. Keyboard | 
| (Failed Keyboard test) | 2. I/O Function Card | 
| 415-XXX-XXX | 1. Modem Card | 
| (Failed modem test) | 
Note 1 - IMPORTANT - This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.
Please see the LEGAL  -  Trademark notice.