| Error Code/Symptom | FRU/Action |
|---|---|
| 001-XXX-XXX | 1. I/O Function Card |
| (Failed core tests) | 2. I/O Board |
| 005-XXX-XXX | 1. I/O Function Card |
| (Failed Video test) | 2. I/O Board |
| 011-XXX-XXX | 1. I/O Function Card |
| (Failed Serial Port test) | 2. I/O Board |
| 014-XXX-XXX | 1. I/O Function Card |
| (Failed Parallel Port test) | 2. I/O Board |
| 015-XXX-XXX | 1. I/O Board |
| (Failed USB test) | |
| 030-XXX-000 | 1. I/O Function Card |
| (Failed Internal SCSI | 2. I/O Board |
| interface test -channel 0) | |
| 030-XXX-001 | 1. I/O Function Card |
| (Failed Internal SCSI | 2. I/O Board |
| interface test -channel 1) | |
| 035-XXX-000 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 1 |
| adapter in slot 1) | 3. SCSI Backplane |
| 035-XXX-001 | 1. Fixed Disk 1 |
| (Failed RAID test for Fixed | 2. SCSI Cable |
| Disk in bay 1 SCSI ID 0) | 3. RAID Adapter |
| Note 1 | 4. SCSI Backplane |
| 035-XXX-001 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 2 |
| adapter in slot 2) | 3. SCSI Backplane |
| Note 1 | |
| 035-XXX-002 | 1. Fixed Disk 2 |
| (Failed RAID test for Fixed | 2. SCSI Cable |
| Disk in bay 2 SCSI ID 1) | 3. RAID Adapter |
| Note 1 | 4. SCSI Backplane |
| 035-XXX-002 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 3 |
| adapter in slot 3) | 3. SCSI Backplane |
| Note 1 | |
| 035-XXX-003 | 1. Fixed Disk 3 |
| (Failed RAID test for Fixed | 2. SCSI Cable |
| Disk in bay 3, SCSI ID 2) | 3. RAID Adapter |
| Note 1 | 4. SCSI Backplane |
| 035-XXX-003 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 4 |
| adapter in slot 4) | 3. SCSI Backplane |
| Note 1 | |
| 035-XXX-004 | 1. Fixed Disk 4 |
| (Failed RAID test for Fixed | 2. SCSI Cable |
| Disk in bay 4, SCSI ID 3) | 3. RAID Adapter |
| Note 1 | 4. SCSI Backplane |
| 035-XXX-004 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 5 |
| adapter in slot 5) | 3. SCSI Backplane |
| Note 1 | |
| 035-XXX-005 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 6 |
| adapter in slot 6) | 3. SCSI Backplane |
| 035-XXX-006 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 7 |
| adapter in slot 7) | 3. SCSI Backplane |
| 035-XXX-007 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 8 |
| adapter in slot 8) | 3. SCSI Backplane |
| 035-XXX-008 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 9 |
| adapter in slot 9) | 3. SCSI Backplane |
| 035-XXX-009 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 10 |
| adapter in slot 10) | 3. SCSI Backplane |
| 035-XXX-010 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 11 |
| adapter in slot 11) | 3. SCSI Backplane |
| 035-XXX-011 | 1. SCSI Cable |
| (Failed RAID test for | 2. RAID Adapter 12 |
| adapter in slot 12) | 3. SCSI Backplane |
| 089-XXX-001 | 1. Processor 1 |
| (Failed Microprocessor test) | 2. VRMs |
| 3. Processor Board | |
| 089-XXX-002 | 1. Processor 2 |
| (Failed Microprocessor test) | 2. VRMs |
| 3. Processor Board | |
| 089-XXX-003 | 1. Processor 3 |
| (Failed Microprocessor test) | 2. VRMs |
| 3. Processor Board | |
| 089-XXX-004 | 1. Processor 4 |
| (Failed Microprocessor test) | 2. VRMs |
| 3. Processor Board | |
| 165-XXX-000 | 1. System Management Card |
| (Failed System | 2. System Management Card Cable |
| Management Card test) | 3. I/O Function Card |
| 170-XXX-XXX | 1. System Management Card |
| (Voltage sensor test failed) | 2. System Management Card Cable |
| 3. Power Control Card | |
| 175-XXX-XXX | 1. System Management Card |
| (Thermal sensor test failed) | 2. System Management Card Cable |
| 180-XXX-000 | 1. System Management Card |
| (LED test failed) | |
| 180-XXX-001 | 1. Front Panel |
| (LED test failed) | 2. System Management Card |
| 180-XXX-002 | 1. Memory Card 1 |
| (LED test failed) | 2. System Management Card |
| 180-XXX-003 | 1. Memory Card 2 |
| (LED test failed) | 2. System Management Card |
| 180-XXX-004 | 1. I/O Board |
| (PCI Power/Attention LED | |
| tests failed) | |
| 180-XXX-005 | 1. PCI Sensor Card |
| (Retention bracket failure) | 2. I/O Board |
| 180-XXX-006 | 1. SCSI Cable |
| (ASPI not loaded) | 2. SCSI Backplane |
| 3. I/O Function Card | |
| 180-XXX-007 | 1. Cable |
| (DASD LED failed, see | 2. DASD backplane |
| message for slot) | |
| 185-XXX-001 | 1. Intrusion (C2 Security) Cable |
| (Intrusion Security test | 2. Front Panel |
| failed) | 3. I/O Function Card |
| 185-XXX-002 | 1. Intrusion (C2 Security) Cable |
| (Intrusion Security test | 2. Front Panel |
| failed) | 3. I/O Function Card |
| 201-XXX-000 | 1. Memory DIMM (see message for Card/DIMM) |
| (Failed Memory Test) | 2. Memory Card |
| 3. Processor Board | |
| 201-XXX-001 | 1. Memory DIMM (Verify failing FRU in system error log.) |
| (Failed ECC test) | |
| 202-XXX-000 | 1. BSP Processor |
| (Failed System Cache test) | 2. Processor Board |
| 206-XXX-XXX | 1. Diskette Drive cable |
| (Failed Diskette Drive test) | 2. Diskette Drive |
| 3. I/O Function Card | |
| 215-XXX-000 | 1. CD-ROM cable |
| (Failed CD-ROM test) | 2. CD-ROM drive |
| 3. I/O Board | |
| 217-XXX-001 | 1. Fixed Disk 1 |
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-002 | 1. Fixed Disk 2 |
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-003 | 1. Fixed Disk 3 |
| (Failed BIOS Fixed Disk | |
| test) | |
| 217-XXX-004 | 1. Fixed Disk 4 |
| (Failed BIOS Fixed Disk | |
| test) | |
| 301-XXX-XXX | 1. Keyboard |
| (Failed Keyboard test) | 2. I/O Function Card |
| 415-XXX-XXX | 1. Modem Card |
| (Failed modem test) |
Note 1 - IMPORTANT - This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.
Please see the LEGAL - Trademark notice.
Feel free - send a