Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Diagnostic Error Codes (Netfinity 7000-M10 - Type 8680)



Diagnostic Error Codes

In the following error codes, X can be any number or letter.

Error Code/Symptom    FRU/Action
  
001-XXX-XXX 1. I/O Function Card
(Failed core tests) 2. I/O Board
  
005-XXX-XXX 1. I/O Function Card
(Failed Video test) 2. I/O Board
  
011-XXX-XXX 1. I/O Function Card
(Failed Serial Port test) 2. I/O Board
  
014-XXX-XXX 1. I/O Function Card
(Failed Parallel Port test) 2. I/O Board
  
015-XXX-XXX 1. I/O Board
(Failed USB test)
030-XXX-000 1. I/O Function Card
(Failed Internal SCSI 2. I/O Board
interface test -channel 0)
030-XXX-001 1. I/O Function Card
(Failed Internal SCSI 2. I/O Board
interface test -channel 1)
035-XXX-000 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 1
adapter in slot 1) 3. SCSI Backplane
  
035-XXX-001 1. Fixed Disk 1
(Failed RAID test for Fixed 2. SCSI Cable
Disk in bay 1 SCSI ID 0) 3. RAID Adapter
Note 1 4. SCSI Backplane
  
035-XXX-001 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 2
adapter in slot 2) 3. SCSI Backplane
Note 1
035-XXX-002 1. Fixed Disk 2
(Failed RAID test for Fixed 2. SCSI Cable
Disk in bay 2 SCSI ID 1) 3. RAID Adapter
Note 1 4. SCSI Backplane
  
035-XXX-002 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 3
adapter in slot 3) 3. SCSI Backplane
Note 1
035-XXX-003 1. Fixed Disk 3
(Failed RAID test for Fixed 2. SCSI Cable
Disk in bay 3, SCSI ID 2) 3. RAID Adapter
Note 1 4. SCSI Backplane
  
035-XXX-003 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 4
adapter in slot 4) 3. SCSI Backplane
Note 1
035-XXX-004 1. Fixed Disk 4
(Failed RAID test for Fixed 2. SCSI Cable
Disk in bay 4, SCSI ID 3) 3. RAID Adapter
Note 1 4. SCSI Backplane
  
035-XXX-004 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 5
adapter in slot 5) 3. SCSI Backplane
Note 1
035-XXX-005 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 6
adapter in slot 6) 3. SCSI Backplane
  
035-XXX-006 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 7
adapter in slot 7) 3. SCSI Backplane
  
035-XXX-007 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 8
adapter in slot 8) 3. SCSI Backplane
  
035-XXX-008 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 9
adapter in slot 9) 3. SCSI Backplane
  
035-XXX-009 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 10
adapter in slot 10) 3. SCSI Backplane
  
035-XXX-010 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 11
adapter in slot 11) 3. SCSI Backplane
  
035-XXX-011 1. SCSI Cable
(Failed RAID test for 2. RAID Adapter 12
adapter in slot 12) 3. SCSI Backplane
  
089-XXX-001 1. Processor 1
(Failed Microprocessor test) 2. VRMs
  3. Processor Board
  
089-XXX-002 1. Processor 2
(Failed Microprocessor test) 2. VRMs
  3. Processor Board
  
089-XXX-003 1. Processor 3
(Failed Microprocessor test) 2. VRMs
  3. Processor Board
  
089-XXX-004 1. Processor 4
(Failed Microprocessor test) 2. VRMs
  3. Processor Board
  
165-XXX-000 1. System Management Card
(Failed System 2. System Management Card Cable
Management Card test) 3. I/O Function Card
  
170-XXX-XXX 1. System Management Card
(Voltage sensor test failed) 2. System Management Card Cable
  3. Power Control Card
  
175-XXX-XXX 1. System Management Card
(Thermal sensor test failed) 2. System Management Card Cable
  
180-XXX-000 1. System Management Card
(LED test failed)
180-XXX-001 1. Front Panel
(LED test failed) 2. System Management Card
  
180-XXX-002 1. Memory Card 1
(LED test failed) 2. System Management Card
  
180-XXX-003 1. Memory Card 2
(LED test failed) 2. System Management Card
  
180-XXX-004 1. I/O Board
(PCI Power/Attention LED
tests failed)
180-XXX-005 1. PCI Sensor Card
(Retention bracket failure) 2. I/O Board
  
180-XXX-006 1. SCSI Cable
(ASPI not loaded) 2. SCSI Backplane
  3. I/O Function Card
  
180-XXX-007 1. Cable
(DASD LED failed, see 2. DASD backplane
message for slot)
185-XXX-001 1. Intrusion (C2 Security) Cable
(Intrusion Security test 2. Front Panel
failed) 3. I/O Function Card
  
185-XXX-002 1. Intrusion (C2 Security) Cable
(Intrusion Security test 2. Front Panel
failed) 3. I/O Function Card
  
201-XXX-000 1. Memory DIMM (see message for Card/DIMM)
(Failed Memory Test) 2. Memory Card
  3. Processor Board
  
201-XXX-001 1. Memory DIMM (Verify failing FRU in system error log.)
(Failed ECC test)
202-XXX-000 1. BSP Processor
(Failed System Cache test) 2. Processor Board
  
206-XXX-XXX 1. Diskette Drive cable
(Failed Diskette Drive test) 2. Diskette Drive
  3. I/O Function Card
  
215-XXX-000 1. CD-ROM cable
(Failed CD-ROM test) 2. CD-ROM drive
  3. I/O Board
  
217-XXX-001 1. Fixed Disk 1
(Failed BIOS Fixed Disk
test)
217-XXX-002 1. Fixed Disk 2
(Failed BIOS Fixed Disk
test)
217-XXX-003 1. Fixed Disk 3
(Failed BIOS Fixed Disk
test)
217-XXX-004 1. Fixed Disk 4
(Failed BIOS Fixed Disk
test)
301-XXX-XXX 1. Keyboard
(Failed Keyboard test) 2. I/O Function Card
  
415-XXX-XXX 1. Modem Card
(Failed modem test)


Note 1 - IMPORTANT - This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.