Error Code/Symptom | FRU/Action |
---|---|
001-XXX-XXX | 1. I/O Function Card |
(Failed core tests) | 2. I/O Board |
005-XXX-XXX | 1. I/O Function Card |
(Failed Video test) | 2. I/O Board |
011-XXX-XXX | 1. I/O Function Card |
(Failed Serial Port test) | 2. I/O Board |
014-XXX-XXX | 1. I/O Function Card |
(Failed Parallel Port test) | 2. I/O Board |
015-XXX-XXX | 1. I/O Board |
(Failed USB test) | |
030-XXX-000 | 1. I/O Function Card |
(Failed Internal SCSI | 2. I/O Board |
interface test -channel 0) | |
030-XXX-001 | 1. I/O Function Card |
(Failed Internal SCSI | 2. I/O Board |
interface test -channel 1) | |
035-XXX-000 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 1 |
adapter in slot 1) | 3. SCSI Backplane |
035-XXX-001 | 1. Fixed Disk 1 |
(Failed RAID test for Fixed | 2. SCSI Cable |
Disk in bay 1 SCSI ID 0) | 3. RAID Adapter |
Note 1 | 4. SCSI Backplane |
035-XXX-001 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 2 |
adapter in slot 2) | 3. SCSI Backplane |
Note 1 | |
035-XXX-002 | 1. Fixed Disk 2 |
(Failed RAID test for Fixed | 2. SCSI Cable |
Disk in bay 2 SCSI ID 1) | 3. RAID Adapter |
Note 1 | 4. SCSI Backplane |
035-XXX-002 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 3 |
adapter in slot 3) | 3. SCSI Backplane |
Note 1 | |
035-XXX-003 | 1. Fixed Disk 3 |
(Failed RAID test for Fixed | 2. SCSI Cable |
Disk in bay 3, SCSI ID 2) | 3. RAID Adapter |
Note 1 | 4. SCSI Backplane |
035-XXX-003 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 4 |
adapter in slot 4) | 3. SCSI Backplane |
Note 1 | |
035-XXX-004 | 1. Fixed Disk 4 |
(Failed RAID test for Fixed | 2. SCSI Cable |
Disk in bay 4, SCSI ID 3) | 3. RAID Adapter |
Note 1 | 4. SCSI Backplane |
035-XXX-004 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 5 |
adapter in slot 5) | 3. SCSI Backplane |
Note 1 | |
035-XXX-005 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 6 |
adapter in slot 6) | 3. SCSI Backplane |
035-XXX-006 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 7 |
adapter in slot 7) | 3. SCSI Backplane |
035-XXX-007 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 8 |
adapter in slot 8) | 3. SCSI Backplane |
035-XXX-008 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 9 |
adapter in slot 9) | 3. SCSI Backplane |
035-XXX-009 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 10 |
adapter in slot 10) | 3. SCSI Backplane |
035-XXX-010 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 11 |
adapter in slot 11) | 3. SCSI Backplane |
035-XXX-011 | 1. SCSI Cable |
(Failed RAID test for | 2. RAID Adapter 12 |
adapter in slot 12) | 3. SCSI Backplane |
089-XXX-001 | 1. Processor 1 |
(Failed Microprocessor test) | 2. VRMs |
3. Processor Board | |
089-XXX-002 | 1. Processor 2 |
(Failed Microprocessor test) | 2. VRMs |
3. Processor Board | |
089-XXX-003 | 1. Processor 3 |
(Failed Microprocessor test) | 2. VRMs |
3. Processor Board | |
089-XXX-004 | 1. Processor 4 |
(Failed Microprocessor test) | 2. VRMs |
3. Processor Board | |
165-XXX-000 | 1. System Management Card |
(Failed System | 2. System Management Card Cable |
Management Card test) | 3. I/O Function Card |
170-XXX-XXX | 1. System Management Card |
(Voltage sensor test failed) | 2. System Management Card Cable |
3. Power Control Card | |
175-XXX-XXX | 1. System Management Card |
(Thermal sensor test failed) | 2. System Management Card Cable |
180-XXX-000 | 1. System Management Card |
(LED test failed) | |
180-XXX-001 | 1. Front Panel |
(LED test failed) | 2. System Management Card |
180-XXX-002 | 1. Memory Card 1 |
(LED test failed) | 2. System Management Card |
180-XXX-003 | 1. Memory Card 2 |
(LED test failed) | 2. System Management Card |
180-XXX-004 | 1. I/O Board |
(PCI Power/Attention LED | |
tests failed) | |
180-XXX-005 | 1. PCI Sensor Card |
(Retention bracket failure) | 2. I/O Board |
180-XXX-006 | 1. SCSI Cable |
(ASPI not loaded) | 2. SCSI Backplane |
3. I/O Function Card | |
180-XXX-007 | 1. Cable |
(DASD LED failed, see | 2. DASD backplane |
message for slot) | |
185-XXX-001 | 1. Intrusion (C2 Security) Cable |
(Intrusion Security test | 2. Front Panel |
failed) | 3. I/O Function Card |
185-XXX-002 | 1. Intrusion (C2 Security) Cable |
(Intrusion Security test | 2. Front Panel |
failed) | 3. I/O Function Card |
201-XXX-000 | 1. Memory DIMM (see message for Card/DIMM) |
(Failed Memory Test) | 2. Memory Card |
3. Processor Board | |
201-XXX-001 | 1. Memory DIMM (Verify failing FRU in system error log.) |
(Failed ECC test) | |
202-XXX-000 | 1. BSP Processor |
(Failed System Cache test) | 2. Processor Board |
206-XXX-XXX | 1. Diskette Drive cable |
(Failed Diskette Drive test) | 2. Diskette Drive |
3. I/O Function Card | |
215-XXX-000 | 1. CD-ROM cable |
(Failed CD-ROM test) | 2. CD-ROM drive |
3. I/O Board | |
217-XXX-001 | 1. Fixed Disk 1 |
(Failed BIOS Fixed Disk | |
test) | |
217-XXX-002 | 1. Fixed Disk 2 |
(Failed BIOS Fixed Disk | |
test) | |
217-XXX-003 | 1. Fixed Disk 3 |
(Failed BIOS Fixed Disk | |
test) | |
217-XXX-004 | 1. Fixed Disk 4 |
(Failed BIOS Fixed Disk | |
test) | |
301-XXX-XXX | 1. Keyboard |
(Failed Keyboard test) | 2. I/O Function Card |
415-XXX-XXX | 1. Modem Card |
(Failed modem test) |
Note 1 - IMPORTANT - This is a duplicate error code used for adapters and disk drives.
To verify the type of failure, see the system error log.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.