| Indicator | Description |
|---|---|
| Microprocessor Bus | If activity on the microprocessor bus is |
| Activity LED | present, the indicator for the slot is lit. |
| Microprocessor VRM | If a VRM or processor fails or is missing, |
| Status LED | the LED will light. |
| Microprocessor | If proper termination of the microprocessor |
| Termination LED | slot 4 is present, the indicator is lit. |
| ERR 0 and | If either LED is on, see 'Symptom-to-FRU Index' |
| ERR 1 LEDs | for an explanation. |
Memory Board LED
| Indicator | Description |
|---|---|
| Memory Module | If a memory module is present and has |
| Status LED | failed, the indicator for the slot is lit. |
I/O Board LEDs
| Indicator | Description |
|---|---|
| Power On LED | If power to a PCI slot is present, the |
| indicator for the slot is lit. | |
| Attention LED | The operating system defines the meaning |
| of this indicator. Refer to the operating | |
| system documentation for more information. |
Advanced Remote Management Controller LEDs
| Indicator | Description |
|---|---|
| Power On LED | If power to the Advanced Remote |
| Management Controller is present, the | |
| indicator is lit. | |
| Processor Error LED | If the processor on the Advanced Remote |
| Management Controller has failed, the | |
| indicator is lit. | |
| Ethernet Activity LED | If the Ethernet controller on the Advanced |
| Remote Management Controller is | |
| transmitting data or receiving data, the | |
| indicator is lit. | |
| Ethernet Link LED | If an active link to the Ethernet controller on |
| the Advanced Remote Management | |
| Controller is present, the indicator is lit. |
Please see the LEGAL - Trademark notice.