GETSTATUS | Use the GETSTATUS command to display the current logical-drive status |
---|---|
for the most recent rebuild, synchronization, or logical-drive migration. | |
The status includes such information as the remaining size of the logical | |
drive, the percentage completed for the function in process, or information | |
about the most recently completed logical-drive function. | |
Supported operating systems: Windows NT, OS/2, NetWare, | |
OpenServer, UnixWare, and DOS | |
Command: | |
IPSSEND GETSTATUS Controller | |
Replace: | |
° Controller with the ServeRAID controller number (1 to 8) | |
REBUILD | Use the REBUILD command to rebuild a designated disk drive. |
This command is valid for disk arrays that contain one or more | |
logical drives that are in the critical (CRT) state. | |
Progress is indicated during the rebuild operation, but you can | |
also use the GETSTATUS command to obtain progress information | |
about the rebuild. | |
Supported operating systems: Windows NT, OS/2, NetWare, | |
OpenServer, UnixWare, and DOS | |
Command: | |
IPSSEND REBUILD Controller DCh DSID NCh NSID | |
Replace: | |
° Controller with the ServeRAID controller number (1 to 8) | |
° DCh with the channel number for the Defunct drive (1 to 3) | |
° DSID with the SCSI ID for the Defunct Drive (0 to 15) | |
° NCh with the channel number for the New Drive (1 to 3) | |
° NSID with the SCSI ID for the New Drive (0 to 15) | |
SETSTATE | Use the SETSTATE command to change the state of a physical device from its |
current state to a new state. | |
Attention You must be very careful when you use | |
this command. For example, you might lose data if you reset a Defunct (DDD) | |
device to Online (ONL) without first performing a Rebuild operation. | |
Supported operating systems: Windows NT, OS/2, NetWare, | |
OpenServer, UnixWare, and DOS | |
Command: | |
IPSSEND SETSTATE Controller Channel SID NState | |
Replace: | |
° Controller with the ServeRAID controller number (1 to 8) | |
° Channel with the channel number for the drive (1 to 3) | |
° SID with the SCSI ID for the drive (0 to 15) | |
° NState with the new state for the drive. | |
Valid states are: EMP for Empty, RDY for Ready, HSP for Hot Spare, | |
SHS for Standby Hot Spare, DDD for Defunct Disk Drive, | |
DHS for Defunct Hot Spare, RBL for Rebuild, SBY for Standby, and | |
ONL for Online. (See 'Setting Physical Device States' for more information.) | |
UNBLOCK | Use the UNBLOCK command to gain access to a blocked logical drive. |
RAID level-0 logical drives become blocked if they are in an array that | |
contains RAID level-1 or level-5 logical drives and the array is being rebuilt. | |
Because the RAID level-0 logical drives cannot be rebuilt, the data stored | |
on the RAID level-0 logical drives is damaged and should not be accessed. | |
After you issue the UNBLOCK command, you must re-create or restore the data | |
previously stored on the RAID level-0 logical drives. | |
Supported operating systems: Windows NT, OS/2, NetWare, | |
OpenServer, UnixWare, and DOS | |
Command: | |
IPSSEND UNBLOCK Controller DriveNum | |
Replace: | |
° Controller with the ServeRAID controller number (1 to 8) | |
° DriveNum with the logical drive number (0 to 7) | |