Note:
| System Board SCSI LEDs | FRU/Action | 
|---|---|
| 1 blink followed by a | 1. Check cables | 
| pause | 2. System Board | 
| (Boot block checksum error) | 3. DASD Backplane | 
| 2 blinks followed by a | 1. Check cables | 
| pause | 2. System Board | 
| (DRAM parity error) | 3. DASD Backplane | 
| 3 blinks followed by a | 1. Run the ServeRAID Flash program. | 
| pause | 2. Check cables | 
| (Code block checksum | 3. System Board | 
| error, flash the ServeRAID | 4. DASD Backplane | 
| controller.) | |
| 4 blinks followed by a | 1. Check cables | 
| pause | 2. System Board | 
| (DRAM DATA) | 3. DASD Backplane | 
| 5 blinks followed by a | 1. Check cables | 
| pause | 2. System Board | 
| (DRAM address error) | 3. DASD Backplane | 
| 6 blinks followed by a | 1. Run the ServeRAID Flash program. | 
| pause | 2. Check cables | 
| (Code block checksum | 3. System Board | 
| error, flash the ServeRAID | 4. DASD Backplane | 
| controller.) | |
| On (solid) | 1. Check jumper J11, see 'System Board Jumpers' | 
| 2. Check cables | |
| 3. System Board | |
| 4. DASD Backplane | 