| 000 | The test passed. | 
|---|---|
| 195 | The Esc key was pressed to abort the test | 
| 197 | This is a warning error and may not indicate | 
| a hardware failure. | 
For all other error codes, replace/follow the FRU/Action indication.
| Error Code/Symptom | FRU/Action | 
|---|---|
| 001-XXX-000 | 1. System Board | 
| (Failed core tests) | |
| 001-XXX-001 | 1. Processor Board | 
| (Failed core tests) | |
| 001-250-000 | 1. System Board | 
| (Failed system board ECC) | |
| 001-250-001 | 1. Processor Board | 
| (Failed processor board ECC) | 2. System Board | 
| 005-XXX-000, 005-XXX-001 | 1. System Board | 
| (Failed Video test) | 2. Processor Board | 
| 011-XXX-000 | 1. System Board | 
| (Failed COM1 Serial Port test) | |
| Note: The external loopback test | |
| of Serial Port A will fail | |
| if run remotely. | |
| 011-XXX-001 | 1. System Board | 
| (Failed COM2 Serial Port test) | |
| 014-XXX-000, 014-XXX-001 | 1. System Board | 
| (Failed Parallel Port test) | |
| 015-XXX-001 | 1. System Board | 
| (Failed USB test) | |
| 020-XXX-000 | 1. Processor Board | 
| (Failed PCI Interface test) | 2. System Board | 
| 020-XXX-001 | 1. Latch on PCI Hot plug Slot #1 | 
| (Failed Hot Swap PCI Latch | 2. System Board | 
| test) | |
| 020-XXX-002 | 1. Latch on PCI Hot plug Slot #2 | 
| (Failed Hot Swap PCI Latch | 2. System Board | 
| test) | |
| 020-XXX-003 | 1. Latch on PCI Hot plug Slot #3 | 
| (Failed Hot Swap PCI Latch | 2. System Board | 
| test) | |
| 020-XXX-004 | 1. Latch on PCI Hot plug Slot #4 | 
| (Failed Hot Swap PCI Latch | 2. System Board | 
| test) | |
| 030-XXX-000, 030-XXX-001 | 1. System Board | 
| (Failed Internal SCSI | |
| interface test) | |
| 035-XXX-000 | 1. Verify RAID adapter | 
| (Failed System Board RAID test. | disable jumper block | 
| Check System Error Log before | is not installed. | 
| replacing a FRU.) | 2. System Board | 
| 3. SCSI Backplane | |
| 4. Cable | |
| 035-XXX-001 | 1. Fixed Disk 1 | 
| (Failed RAID test for Fixed | |
| Disk in bay 1 SCSI ID 0 | |
| 035-XXX-002 | 1. Fixed Disk 2 | 
| (Failed RAID test for Fixed | |
| Disk in bay 2 SCSI ID 1 | |
| 035-XXX-003 | 1. Fixed Disk 3 | 
| (Failed RAID test for Fixed | |
| Disk in bay 3, SCSI ID 2) | |
| 035-XXX-004 | 1. Fixed Disk 4 | 
| (Failed RAID test for Fixed | |
| Disk in bay 4, SCSI ID 3) | |
| 035-XXX-005 | 1. Fixed Disk 5 | 
| (Failed RAID test for Fixed | |
| Disk in bay 5, SCSI ID 4) | |
| 035-XXX-006 | 1. Fixed Disk 6 | 
| (Failed RAID test for Fixed | |
| Disk in bay 6, SCSI ID 5) | |
| 035-XXX-007 | 1. System Board | 
| (Failed System Board RAID | |
| test) | |
| 035-XXX-100 | 1. Adapter | 
| (Failed RAID test on PCI | 2. SCSI Backplane | 
| slot 1. Check System Error | 3. Cable | 
| Log before replacing a FRU.) | |
| 035-XXX-1NN | 1. Fixed Disk with SCSI | 
| (Check System Error Log | ID NN on RAID | 
| before replacing a FRU. | adapter in PCI slot 1 | 
| NN = SCSI ID of failing | |
| fixed disk.) | |
| 035-XXX-200 | 1. Adapter | 
| (Failed RAID test on PCI | 2. SCSI Backplane | 
| slot 2. Check System Error | 3. Cable | 
| Log before replacing a FRU.) | |
| 035-XXX-2NN | 1. Fixed Disk with SCSI | 
| (Check System Error Log | ID NN on RAID | 
| before replacing a FRU. | adapter in PCI slot 2 | 
| NN = SCSI ID of failing | |
| fixed disk.) | |
| 035-XXX-300 | 1. Adapter | 
| (Failed RAID test on PCI | 2. SCSI Backplane | 
| slot 3. Check System Error | 3. Cable | 
| Log before replacing a FRU.) | |
| 035-XXX-3NN | 1. Fixed Disk with SCSI | 
| (Check System Error Log | ID NN on RAID | 
| before replacing a FRU. | adapter in PCI slot 3 | 
| NN = SCSI ID of failing | |
| fixed disk.) | |
| 035-XXX-400 | 1. Adapter | 
| (Failed RAID test on PCI | 2. SCSI Backplane | 
| slot 4. Check System Error | 3. Cable | 
| Log before replacing a FRU.) | |
| 035-XXX-4NN | 1. Fixed Disk with SCSI | 
| (Check System Error Log | ID NN on RAID | 
| before replacing a FRU. | adapter in PCI slot 4 | 
| NN = SCSI ID of failing | |
| fixed disk.) | |
| 035-XXX-500 | 1. Adapter | 
| (Failed RAID test on PCI | 2. SCSI Backplane | 
| slot 5. Check System Error | 3. Cable | 
| Log before replacing a FRU.) | |
| 035-XXX-5NN | 1. Fixed Disk with SCSI | 
| (Check System Error Log | ID NN on RAID | 
| before replacing a FRU. | adapter in PCI slot 5 | 
| NN = SCSI ID of failing | |
| fixed disk.) | |
| 035-253-N00 | 1. ServeRAID Adapter is not | 
| (RAID initialization error for | configured correctly. | 
| adapter in PCI slot number N.) | Refer to theIBM ServeRAID HMM | 
| for more information. | |
| 075-XXX-000, 075-XXX-001 | 1. Power Supply | 
| (Failed Power Supply test) | |
| 089-XXX-001 | 1. VRM 1 or VRM 2 | 
| (Failed Microprocessor test) | 2. Microprocessor CPU 1 | 
| 089-XXX-002 | 1. VRM 3 or VRM 2 | 
| (Failed Microprocessor test) | 2. Microprocessor CPU 2 | 
| 089-XXX-003 | 1. VRM 4 or VRM 5 | 
| (Failed Microprocessor test) | 2. Microprocessor CPU 3 | 
| 089-XXX-004 | 1. VRM 6 or VRM 5 | 
| (Failed Microprocessor test) | 2. Microprocessor CPU 4 | 
| 165-XXX-000 | 1. System Board | 
| (Failed System Board test) | 2. Hot-Swap Drive Backplane | 
| 165-XXX-001 | 1. System Board | 
| (Failed System Board test) | 2. Processor Board | 
| 3. Power Backplane | |
| 4. Hot-Swap Drive Backplane | |
| 175-XXX-001 | 1. Fan 1 | 
| (Failed Fan 1 test) | |
| 175-XXX-002 | 1. Fan 2 | 
| (Failed Fan 2 test) | |
| 175-XXX-003 | 1. Fan 3 | 
| (Failed Fan 3 test) | |
| 175-XXX-004 | 1. Check system cooling | 
| (Processor Board | |
| Temperature sensor out of | |
| range) | |
| 180-XXX-000 | |
| (Diagnostics LED failure) | 1. Run Diagnostic LED test for the failing LED | 
| 180-XXX-001 | 1. Information LED Panel | 
| (Failed Information Panel | 2. Power Switch Assembly | 
| LED test) | |
| 180-XXX-002 | 1. Diagnostics LED Panel | 
| (Failed Diagnostics LED | 2. Power Switch Assembly | 
| Panel test) | |
| 180-XXX-003 | 1. Run hot-swap PCI latch test in | 
| (Failed System Board LED | Other Devices under Extended Tests | 
| test) | 2. System Board | 
| 180-XXX-004 | 1. Processor Board | 
| (Failed Processor Board | 2. System Board | 
| LED test) | |
| 180-XXX-005 | 1. Hot Swap SCSI Backplane | 
| (Failed Hot Swap SCSI | 2. SCSI Backplane Cable | 
| Backplane LED test) | 3. System Board | 
| 201-XXX-001 | 1. DIMM Location J15 for 5000-8659, J1 for 5500-866x | 
| (Failed Memory test, | |
| for 5000-8659 see Memory Settings | |
| for 5500-866x see Memory Settings) | |
| 201-XXX-002 | 1. DIMM Location J16 for 5000-8659, J2 for 5500-866x | 
| (Failed Memory test, | |
| for 5000-8659 see Memory Settings | |
| for 5500-866x see Memory Settings) | |
| 201-XXX-003 | 1. DIMM Location J17 for 5000-8659, J3 for 5500-866x | 
| (Failed Memory test, | |
| for 5000-8659 see Memory Settings | |
| for 5500-866x see Memory Settings) | |
| 201-XXX-004 | 1. DIMM Location J22 for 5000-8659, J4 for 5500-866x | 
| (Failed Memory test, | |
| for 5000-8659 see Memory Settings | |
| for 5500-866x see Memory Settings) | |
| 201-XXX-005 | 1. DIMM Location J5 | 
| (Failed Memory test, | |
| See Memory Settings) | |
| 201-XXX-006 | 1. DIMM Location J6 | 
| (Failed Memory test, | |
| See Memory Settings) | |
| 201-XXX-007 | 1. DIMM Location J7 | 
| (Failed Memory test, | |
| See Memory Settings) | |
| 201-XXX-008 | 1. DIMM Location J8 | 
| (Failed Memory test, | |
| See Memory Settings) | |
| 201-XXX-999 | 1. See error text for failing DIMMs | 
| (Multiple DIMM failure, | |
| see error text) | |
| 202-XXX-001 | 1. VRM 2 or VRM 1 | 
| (Failed System Cache test) | 2. Microprocessor CPU 1 | 
| 202-XXX-002 | 1. VRM 2 or VRM 3 | 
| (Failed System Cache test) | 2. Microprocessor CPU 2 | 
| 202-XXX-003 | 1. VRM 5 or VRM 4 | 
| (Failed System Cache test) | 2. Microprocessor CPU 3 | 
| 202-XXX-004 | 1. VRM 5 or VRM 6 | 
| (Failed System Cache test) | 2. Microprocessor CPU 4 | 
| 206-XXX-000, 206-XXX-001 | 1. Diskette Drive cable | 
| (Failed Diskette Drive test) | 2. Diskette Drive | 
| 3. System Board | |
| 215-XXX-000 | 1. CD-ROM Drive Cable | 
| (Failed IDE CD-ROM test) | 2. CD-ROM Drive | 
| 3. System Board | |
| 215-XXX-001 | 1. System Board | 
| (Failed IDE test) | |
| 217-XXX-000 | 1. Fixed Disk 1 (8659, 8661, 8662) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-001 | 1. Fixed Disk 2 (8659, 8661, 8662) 1 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-002 | 1. Fixed Disk 3 (8659, 8661, 8662) 2 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-003 | 1. Fixed Disk 4 (8659, 8661, 8662) 3 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-004 | 1. Fixed Disk 5 (8659, 8661, 8662) 4 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-005 | 1. Fixed Disk 6 (8659, 8661, 8662) 5 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 217-XXX-006 | 1. Fixed Disk 6 (8660) | 
| (Failed BIOS Fixed Disk | |
| test) | |
| Note If RAID is | |
| configured, the fixed disk | |
| number refers to the RAID | |
| logical drive. | |
| 264-XXX-0NN | 1. Tape Cartridge, if user executed the | 
| (NN = SCSI ID of failing | Read/Write Tape Drive test (xxx = 256) | 
| Tape Drive) | 2. SCSI or Power Cable connected to tape drive | 
| with SCSI ID NN. | |
| 3. Tape Drive with SCSI ID NN. | |
| 4. System board or SCSI Controller. (Run SCSI | |
| Controller Diagnostic to determine if the SCSI | |
| bus is functioning properly.) | |
| 264-XXX-999 | 1. See error messages/text in the | 
| (Errors on multiple tape | error log for detailed information on each | 
| drives, see error text for | individual tape drive error. | 
| more info) | |
| 301-XXX-000, 301-XXX-001 | 1. Keyboard | 
| (Failed Keyboard test) | |
| 405-XXX-000 | 1. Verify that the Ethernet Disable Jumper is | 
| (Failed Ethernet test on | not installed. | 
| controller on the system | 2. System Board | 
| board) | |
| 405-XXX-00N | 1. Adapter in PCI slot N | 
| (Failed Ethernet test on | 2. System Board | 
| adapter in PCI slot N) | |
| 415-XXX-000 | 1. Cable | 
| (Failed Modem test) | 2. Modem | 
| 3. System Board | 
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.