RPL-Related Error Messages
If a failure condition occurs after the Ethernet controller is initialized, an error message appears
on the screen.
The two most common error messages are:
RPL-ROM-ERR: 105
The integrated Ethernet failed the loopback test.
RPL-ROM-ERR: 107
Media test failed; check the cable.
Error 105 indicates that a power-on diagnostic test performed by the Ethernet module did not execute
correctly. If this error message appears, you must have the server serviced.
Error 107 indicates that the cable from the LAN is not securely connected to the Ethernet port on the
computer. Check the cable to ensure that it is properly connected.
The following list contains other error codes that might occur, followed by a description of the error code.
NOTE: An x value that follows an error code represents any alphanumeric character.
Error Code Messages | |
---|---|
RPL-ROM-ERR: 100 | The integrated Ethernet controller cannot be found |
RPL-ROM-ERR: 101 | The integrated Ethernet controller was unable to intialize |
RPL-ROM-ERR: 102 | The integrated Ethernet controller could not be reset |
RPL-ROM-ERR: 103 | There are multiple Ethernet controllers or adapters in the |
system. Specify the correct serial number in the NET.CFG file | |
RPL-ROM-ERR: 104 | The integrated Ethernet controller EEPROM is faulty |
or not present | |
RPL-ROM-ERR: 106 | The integrated Ethernet controller is configured for |
Plug and Play in a non-Plug and Play system | |
RPL-ROM-ERR: 107 | The media test failed. |
The cable from the LAN is not securely connected to the Ethernet | |
port on the server. Check the cable to ensure that it is properly | |
connected. | |
RPL-ROM-ERR: 110 | The integrated Ethernet controller RAM failed the memory test |
E61 | Service boot (startup) canceled, that is, the boot diskette |
image was not downloaded from the network | |
E62 | Cannot initialize controller |
E63 | Cannot initialize controller |
E67 | Cannot initialize controller |
E6d | Cannot find boot protocol (BOOTP) server |
E6e | Cannot start from downloaded image |
E71 | Too many multicast trivial file transfer protocol (MTFTP) |
packages | |
M10 | Address resolution protocol (ARP) canceled by keystroke |
M11 | ARP timeout |
M20 | Cannot copy memory |
M21 | Cannot write to memory |
M22 | Cannot write to memory |
M30 | Cannot ARP trivial file transfer protocol (TFTP) address |
M31 | TFTP cancelled by keystroke |
M32 | TFTP open timeout |
M33 | Unknown TFTP parameter (operation code) |
M34 | TFTP read canceled by keystroke |
M35 | TFTP timeout |
M38 | Cannot open TFTP connection |
M39 | Cannot read from TFTP connection |
M40 | BOOTP canceled by keystroke |
M40 | DHCP canceled by keystroke |
M41 | BOOTP timeout |
M41 | DHCP timeout |
M42 | No client or server Internet protocol (IP) address |
M43 | No boot (startup) file name |
M44 | Cannot ARP redirected BOOTP server |
M6f | System is locked. Press Ctrl+Alt+Del to restart |
M90 | Cannot initialize controller for multicast address |
M91 | MTFTP cancelled by keystroke |
M92 | MTFTP open timeout |
M93 | Unknown MTFTP parameter (operation code) |
M94 | MTFTP read canceled by keystroke |
M95 | MTFTP timeout |
M96 | Cannot ARP MTFTP address |
M98 | Cannot open MTFTP connection |
M99 | Cannot read from MTFTP connection |
Txx | If you are running a TFTP session to another computer, |
an error message generated by the TFTP session will | |
contain a message prefix of Txx |